Frequency Regulation Strategy in Islanded Microgrid With High Renewable Penetration Supported by Virtual Inertia

被引:0
作者
Suman, Gourav Kumar [1 ]
Yadav, Suman [2 ]
Guerrero, Josep M. [3 ]
机构
[1] Madanapalle Inst Technol & Sci, Dept Elect & Commun Engn, Madanapalle 517325, Andhra Pradesh, India
[2] Madanapalle Inst Technol & Sci, Dept Elect & Elect Engn, Madanapalle 517325, Andhra Pradesh, India
[3] Tech Univ Catalonia, Ctr Res Micro, Barcelona 08019, Spain
关键词
Virtual-inertia; Microgrid stability; FOPID; Robustness; Optimisation; TLBO; CONTROLLER; DESIGN; OPTIMIZATION; SYSTEM; LFC;
D O I
10.1007/s40866-024-00211-7
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The widespread adoption of power converter-based renewable energy sources (RESs) has led to a significant decline in overall system inertia within interconnected power systems. This reduction in inertia poses a significant challenge, as it increases the susceptibility of the interconnected power system to instability. To address this critical issue, this research proposes an application of virtual inertia control as a means to enhance the frequency stability of interconnected power systems characterized by a high penetration level of RESs. The proposed approach leverages a derivative control technique to enable higher-level virtual inertia emulation. By introducing a second-order characteristic into the virtual inertia control loop, the method emulates inertia, resulting in improved frequency stability and enhanced system resiliency. A dynamic model of microgrid linked is developed and the frequency stability is ensured by a Fractional Order Proportional Integral Derivative (FOPID) controller using Teaching Learning Based Optimisation (TLBO) algorithm. The problem is formulated with Integral Time Squared Error (ITSE) of frequency deviation for determining the controller. The performance of the developed controller is compared against conventional controllers in terms of the stability of the microgrid. In addition, the superiority of TLBO is analysed by comparing it with other well-established algorithms in the literature. The suitability is established under various scenarios of load and renewable uncertainties. Furthermore, the work also includes sensitivity verification of the controller by parametric variation of the range of +/- 70%\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\pm 70\%$$\end{document}.
引用
收藏
页数:20
相关论文
共 46 条