Three-dimensional magnetic resonance cholangiography is superior to two-dimensional single-shot magnetic resonance cholangiography for visualization and image quality of the feline and canine biliary tract: A postmortem study

被引:1
|
作者
Rahmani, Vahideh [1 ,5 ]
Peltonen, Juha [2 ]
Hmelnikov, Dmitri [2 ]
Uosyte, Raimonda [3 ]
Mannikko, Sofia [4 ]
Spillmann, Thomas [1 ]
Ruohoniemi, Mirja [1 ]
机构
[1] Univ Helsinki, Fac Vet Med, Dept Equine & Small Anim Med, Helsinki, Finland
[2] Helsinki Univ Hosp, Univ Helsinki, HUS Med Imaging Ctr, Radiol, Helsinki, Finland
[3] KAIVANA Small Anim Clin, Kaunas, Lithuania
[4] Pharma Ltd, Turku, Finland
[5] Univ Helsinki, Fac Vet Med, Dept Equine & Small Anim Med, Koetilankuja 1, Helsinki 00790, Finland
关键词
biliary system; canine; diagnostic imaging; feline; magnetic resonance imaging; FAST SPIN-ECHO; MR CHOLANGIOPANCREATOGRAPHY; PULSE SEQUENCE; TEMPERATURE; TIME;
D O I
10.1111/vru.13372
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Magnetic resonance cholangiography (MRC) is an established diagnostic tool for noninvasive assessment of the biliary tract in humans. It has also been found to be feasible in companion animals, but no published studies have compared MRC sequences in veterinary medicine. The present study is part of a prospective, observational, analytical investigation on MR cholangiopancreatography performed on the donated bodies of 12 cats and eight dogs. The main aim of this study was to compare the images of 2D-SSh-TSE-MRC and 3D-TSE-MRC sequences for visualization and image quality of the feline and canine biliary tract. Both sequences are T2-weighted and noncontrast. Three independent readers scored the visibility of four segments of the biliary tract, namely the gallbladder (GB), cystic duct, common bile duct (CBD), and extrahepatic ducts, and the image quality of the two MRC sequences using five-point Likert scales. Wilcoxon signed-rank test was used to compare the scores between the MRC sequences separately for cats and dogs. Inter- and intraobserver agreements were measured using Gwet's AC2 with linear weighting. The 3D-TSE-MRC images were scored significantly higher than the 2D-SSh-TSE-MRC for both visibility and image quality (P < .001-.016 for cats, P = .008-.031 for dogs); the only exception was GB in dogs. In both cats and dogs, interobserver agreement for segment visibility and image quality ranged from slight to substantial in 2D-SSh-TSE-MRC and from poor to almost perfect in 3D-TSE-MRC. Most of the assessments (73% for segment visibility and 66% for image quality) had substantial to almost perfect intraobserver agreement. Findings from the current study support the use of 3D-TSE-MRC over 2D-SSh-TSE-MRC for evaluation of the feline and canine biliary tract, but further studies on live animals are warranted.
引用
收藏
页码:377 / 384
页数:8
相关论文
共 27 条
  • [21] Magnetic Resonance Imaging in Patients With Mechanical Low Back Pain Using a Novel Rapid-Acquisition Three-Dimensional SPACE Sequence at 1.5-T: A Pilot Study Comparing Lumbar Stenosis Assessment With Routine Two-Dimensional Magnetic Resonance Sequences
    Swami, Vimarsha G.
    Katlariwala, Mihir
    Dhillon, Sukhvinder
    Jibri, Zaid
    Jaremko, Jacob L.
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2016, 67 (04): : 368 - 378
  • [22] Magnetic Resonance Imaging of Ankle Syndesmotic Ligament Injuries: Comparison of Three-dimensional Isotropic Intermediate-weighted Fast Spin Echo with Conventional Two-dimensional Imaging
    Park, J. W.
    Lee, S. J.
    Choo, H. J.
    Gwak, H. C.
    Park, D. H.
    Kim, M. W.
    HONG KONG JOURNAL OF RADIOLOGY, 2020, 23 (03): : 391 - 397
  • [23] Measurement of left ventricular mass by real-time three-dimensional echocardiography: validation against magnetic resonance and comparison with two-dimensional and M-mode measurements
    Takeuchi, Masaaki
    Nishikage, Tomoko
    Mor-Avi, Victor
    Sugeng, Lissa
    Weinert, Lynn
    Nakai, Hironi
    Salgo, Ivan S.
    Gerard, Olivier
    Lang, Roberto M.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (09) : 1001 - 1005
  • [24] Tomographic three-dimensional echocardiographic determination of chamber size and systolic function in patients with left ventricular aneurysm - Comparison to magnetic resonance imaging, cineventriculography, and two-dimensional echocardiography
    Buck, T
    Hunold, P
    Wentz, KU
    Tkalec, W
    Nesser, HJ
    Erbel, R
    CIRCULATION, 1997, 96 (12) : 4286 - 4297
  • [25] Feasibility of left ventricular volume measurements by three-dimensional speckle tracking echocardiography depends on image quality and degree of left ventricular enlargement: Validation study with cardiac magnetic resonance imaging
    Kawamura, Ryo
    Seo, Yoshihiro
    Ishizu, Tomoko
    Atsumi, Akiko
    Yamamoto, Masayoshi
    Machino-Ohtsuka, Tomoko
    Nakajima, Hideki
    Sakai, Satoshi
    Tanaka, Yumiko Oishi
    Minami, Manabu
    Aonuma, Kazutaka
    JOURNAL OF CARDIOLOGY, 2014, 63 (3-4) : 230 - 238
  • [26] Differential Diagnosis of Mimicking Tumor Discs Using Coronal Magnetic Resonance Imaging of Three-Dimensional Fast-Field Echo with Water-Selective Excitation: A Single Center Retrospective Study
    Yuan, Jinghong
    Du, Zhi
    Wu, Zhiwen
    Yin, Jianhua
    Cheng, Bingxue
    Xiong, Xi
    Zheng, Sikuan
    Liu, Xijuan
    Jia, Jingyu
    Cheng, Xigao
    ORTHOPAEDIC SURGERY, 2022, 14 (12) : 3330 - 3339
  • [27] Magnetic resonance cholangiopancreatography at 3T in a single breath-hold: comparative effectiveness between three-dimensional (3D) gradient- and spin-echo and two-dimensional (2D) thick-slab fast spin-echo acquisitions
    Chien, Cheng-Ping
    Chiu, Feng-Mao
    Shen, Yen-Chun
    Chen, Yi-Hsun
    Chung, Hsiao-Wen
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (06) : 1265 - 1274