Pilot HVDC line protection scheme based on ratio of superimposed current

被引:0
|
作者
Li X. [1 ]
Tian R. [2 ]
Luo X. [2 ]
Wang H. [2 ]
Pang G. [3 ]
机构
[1] State Grid Sichuan Electric Power Research Institute, Chengdu
[2] School of Electrical Engineering, Xi'an Jiaotong University, Xi'an
[3] China Electric Power Research Institute, Beijing
关键词
DC filter; Electric power system protection; Electric power transmission; HVDC power transmission; Pilot protection; S transform; Superimposed current;
D O I
10.16081/j.epae.201909028
中图分类号
学科分类号
摘要
Since the current differential protection for HVDC transmission line is of poor reliability and operates with long time delay, a novel pilot HVDC line protection scheme based on the ratio of superimposed current is proposed. The ratio of superimposed current at specific frequency measured at DC filter to superimposed current measured at DC line is used to identify the line faults. For internal faults, the ratios of superimposed current at rectifier side and inverter side are both close to 1, while for external faults one of the two ratios is always much greater than 1. The simulative results and the test with field data indicate that the proposed protection scheme can identify the internal and external faults accurately under various fault conditions. © 2019, Electric Power Automation Equipment Press. All right reserved.
引用
收藏
页码:33 / 38
页数:5
相关论文
共 17 条
  • [1] Shen Y., Xiong Y., Yao W., Et al., Comprehensive evaluation for receiving end connection scheme of ±1100 kV UHVDC power transmission, Electric Power Automation Equipment, 38, 8, pp. 195-202, (2018)
  • [2] Shu H., Tian X., Entire-line instant protection based on PCA clustering for ±800 kV HVDC transmission line, Electric Power Automation Equipment, 36, 1, pp. 51-59, (2016)
  • [3] Li A., Cai Z., Sun Q., Et al., Criterion of HVDC line differential protection blocking based on spectrum comparison, Electric Power Automation Equipment, 35, 4, pp. 115-120, (2015)
  • [4] Gao S., Suonan J., Song G., Et al., A novel pilot protection principle for HVDC transmission lines based on current fault component, Automation of Electric Power Systems, 35, 5, pp. 52-56, (2011)
  • [5] Chen S., Cao R., Bi G., Et al., Single-end current direction transient protection based on morphology for UHVDC transmission line, Electric Power Automation Equipment, 36, 1, pp. 67-72, (2016)
  • [6] Wang G., Luo J., Li H., Et al., Transient energy protection for ±800 kV UHVDC transmission lines, Automation of Electric Power Systems, 34, 1, pp. 28-32, (2010)
  • [7] Yang Y., Tai N., Liu J., Et al., A pilot protection scheme for transmission lines based on boundary energy, Proceedings of the CSEE, 35, 22, pp. 5757-5767, (2015)
  • [8] Kong F., Zhang B., Wang Y., Et al., A novel pilot protection scheme for HVDC transmission based on waveform correlation analysis of traveling wave, Automation of Electric Power Systems, 38, 20, pp. 108-114, (2014)
  • [9] Liu J., Tai N., Fan C., Et al., A novel pilot protection scheme for HVDC transmission line based on current waveform matching, Power System Technology, 39, 6, pp. 1736-1743, (2016)
  • [10] Shu H., Tian X., Dong J., Et al., Identification between internal and external faults of ±800 kV UHVDC transmission lines based on voltage correlation, Proceedings of the CSEE, 32, 4, pp. 151-160, (2012)