Relative Humidity Sensing Based on Passively Mode-Locked Fiber Laser With Polyimide-Coated Fiber

被引:6
作者
Ma, Shaonian [1 ,2 ]
Pang, Yuxi [1 ,2 ]
Ji, Qiang [1 ,2 ]
Zhao, Xian [1 ,2 ]
Qin, Zengguang [3 ]
Liu, Zhaojun [3 ]
Xu, Yanping [1 ,2 ]
机构
[1] Shandong Univ, Key Lab Laser & Infrared Syst, Minist Educ, Qingdao 266237, Peoples R China
[2] Shandong Univ, Ctr Opt Res & Engn, Qingdao 266237, Peoples R China
[3] Shandong Univ, Sch Informat Sci & Engn, Qingdao 266237, Peoples R China
关键词
Fiber laser sensor; humidity sensor; multilongitudinal mode; passively mode locking; polyimide fiber; RING LASER; SENSOR;
D O I
10.1109/JSEN.2024.3352616
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Commercial polyimide-coated single-mode fiber (PI-SMF) with excellent water affinity properties has shown great potential in realizing robust and efficient humidity sensing. In this article, relative humidity (RH) sensing utilizing a passively mode-locked fiber laser (MLFL) combined with a beat frequency demodulation system is proposed and experimentally demonstrated. A PI-SMF in the fiber ring cavity is used as a sensing element, of which the length varies with humidity by volume-variation induced strain, leading to the frequency shift of the MLFL beat frequency signals (BFSs). In the range of 25%-85% RH, the frequency of the 2000 MHz BFS responds linearly with RH, with a sensitivity of -2.24 kHz/RH%. Thanks to the high frequency resolution of the beat frequency demodulation system, the RH resolution can reach 0.022 RH%. In addition, the experimental results demonstrate that the sensing approach has good long-term stability with root-mean-square (rms) deviation of <= 0.2 % RH and repeatability with a sensitivity deviation of < 0.2% over 4 weeks. These advantages of high resolution and excellent long-term stability make it suitable for potential applications in areas such as food safety, electronic storage, and pharmaceutical manufacturing.
引用
收藏
页码:6257 / 6263
页数:7
相关论文
共 27 条
[1]   Relative Humidity Sensing using PANI/PVA integrated with Feedback Oscillator Circuit [J].
Abdolrazzaghi, Mohammad ;
Hariri, Faissal ;
Chu, Marco ;
Naguib, Hani ;
Daneshmand, Mojgan .
2019 IEEE SENSORS, 2019,
[2]   AI-Assisted Ultra-High-Sensitivity/Resolution Active-Coupled CSRR-Based Sensor with Embedded Selectivity [J].
Abdolrazzaghi, Mohammad ;
Kazemi, Nazli ;
Nayyeri, Vahid ;
Martin, Ferran .
SENSORS, 2023, 23 (13)
[3]   Analysis of Polyimide-Coated Optical Fiber Long-Period Grating-Based Relative Humidity Sensor [J].
Alwis, Lourdes ;
Sun, Tong ;
Grattan, Kenneth V. .
IEEE SENSORS JOURNAL, 2013, 13 (02) :767-771
[4]   Recent Developments in Fiber Optics Humidity Sensors [J].
Ascorbe, Joaquin ;
Corres, Jesus M. ;
Arregui, Francisco J. ;
Matias, Ignacio R. .
SENSORS, 2017, 17 (04)
[5]   Optical fiber based on humidity sensor with improved sensitivity for monitoring applications [J].
Bian, Ce ;
Wang, Jie ;
Bai, Xiaohong ;
Hu, Manli ;
Gang, Tingting .
OPTICS AND LASER TECHNOLOGY, 2020, 130
[6]   Low Temperature Cross-Sensitivity Humidity Sensor Based on a U-Shaped Microfiber Interferometer [J].
Fu, Haiwei ;
Jiang, Youhua ;
Ding, Jijun ;
Zhang, Jingle .
IEEE SENSORS JOURNAL, 2017, 17 (03) :644-649
[7]   Study on fiber ring laser in sensing application with beat frequency demodulation [J].
Gao, Liang ;
Huang, Long ;
Chen, Lin ;
Chen, Xiangfei .
OPTICS AND LASER TECHNOLOGY, 2013, 45 :137-141
[8]   Low-cost relative humidity sensor based on thermoplastic polyimide-coated fiber Bragg grating [J].
Huang, X. F. ;
Sheng, D. R. ;
Cen, K. F. ;
Zhou, H. .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 127 (02) :518-524
[9]   In-human testing of a non-invasive continuous low-energy microwave glucose sensor with advanced machine learning capabilities [J].
Kazemi, Nazli ;
Abdolrazzaghi, Mohammad ;
Light, Peter E. ;
Musilek, Petr .
BIOSENSORS & BIOELECTRONICS, 2023, 241
[10]   Relative humidity sensor with optical fiber Bragg gratings [J].
Kronenberg, P ;
Rastogi, PK ;
Giaccari, P ;
Limberger, HG .
OPTICS LETTERS, 2002, 27 (16) :1385-1387