Impact of glazing to wall ratio in various climatic regions: A case study

被引:46
作者
Alwetaishi M. [1 ]
机构
[1] Department of Civil Engineering, College of Engineering, Taif University
关键词
Building design in different climates; Building performance; Glazing system in building; Impact of glazing ratio; Microclimate;
D O I
10.1016/j.jksues.2017.03.001
中图分类号
学科分类号
摘要
It is architecturally accepted that glazing system is considered as the most fragile part of buildings in terms of energy indoor performance. It is the only part of the building which has direct solar gain due to the transparent materials. Consequently, this part of building envelope should reap high consideration by architects and engineers, particularly in regions where solar radiation is high. The research aims to investigate the influence of glazing to wall ratio in different microclimate regions in Saudi Arabia which has been introduced by the author hot dry, hot humid and moderate climates. The research has studied the most possible glazing ration in the region based on previous work 5%, 10%, 20%, 30% and 40% out of the external wall. The paper used computer modelling TAS EDSL which has been validated using field monitoring study. Moreover, globe thermometer be used in order to investigate the impact of student's position with respect to glazing system. Finally, questionnaire will be utilised to obtain actual thermal comfort from students in the selected regions with maintaining the same PSBD. The study reveals that south and east directions are the worst in terms of gaining the maximum amount of heat in all the locations. The research suggest that glazing to wall ratio is recommended to be 10% in both climate conditions hot and dry and hot and humid. © 2017 King Saud University
引用
收藏
页码:6 / 18
页数:12
相关论文
共 26 条
[1]  
Abdullatif E., Minimising thermal bridging through window systems in buildings of hot regions, J. Appl. Therm. Eng., 22, pp. 989-998, (2002)
[2]  
Adrian T., Joanna R., Energy labelling of windows – possibilities and limitations, J. Solar Energy, 120, pp. 158-174, (2015)
[3]  
Alwetaishi M., Human Thermal Comfort and Building Performance of Schools in Hot and Humid Climate with a Particular Reference to Saudi Arabia, (2015)
[4]  
Andrea G., Giovanni P., Francesca C., Analysis and modelling of window and glazing systems energy performance for a well-insulated residential building, J. Energy Build., 35, pp. 1030-1037, (2011)
[5]  
Bouchlaghem N., Optimising the design of building envelopes for thermal performance, J. Autom. Constr., 10, pp. 101-112, (2000)
[6]  
Cinzia B., Linda B., Elisa M., Application of artificial neural network to predict thermal transmittance of wooden windows, J. Appl. Energy, 98, pp. 425-432, (2012)
[7]  
Francesco G., Search for the optimal window-to-wall ratio in office buildings in different European climates and the implications on total energy saving potential, J. Solar Energy, 132, pp. 467-492, (2016)
[8]  
Gunnlaug S., Christian H., Svend S., Roadmap for improving roof and façade windows in nearly zero-energy houses in Europe, J. Energy Build., 116, pp. 602-613, (2016)
[9]  
Hassouneh K., Alshboul A., Salaymeh A., Influence of windows on the energy balance of apartment buildings in Amman, J. Energy Convers. Manage., 51, pp. 1583-1591, (2010)
[10]  
Kamal M., Greig N., Alhomid A., Al-Jafari A., ‘Kinetics of human acetylcholinesterase inhabitation by the Novel experimental Alzheimer therapeutic agent, Tolserine’ J. Biochem. Pharmacol., 60, pp. 561-570, (2000)