Evaluation of augmented reality training for a navigation device used for CT-guided needle placement

被引:1
作者
Stauffer, T. [1 ]
Lohmeyer, Q. [1 ]
Melamed, S. [2 ]
Uhde, A. [2 ]
Hostettler, R. [2 ]
Wetzel, S. [2 ,3 ]
Meboldt, M. [1 ]
机构
[1] Swiss Fed Inst Technol, Prod Dev Grp Zurich, Leonhard Str 21, CH-8092 Zurich, Switzerland
[2] Med Templates AG, Technopk Str 1, CH-8005 Zurich, Switzerland
[3] Hirslanden Clin Zurich, Dept Neuroradiol, Witelliker Str 40, CH-8032 Zurich, Switzerland
关键词
Medical education; Augmented reality; User study; Interventional radiology;
D O I
10.1007/s11548-024-03112-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Numerous navigation devices for percutaneous, CT-guided interventions exist and are, due to their advantages, increasingly integrated into the clinical workflow. However, effective training methods to ensure safe usage are still lacking. This study compares the potential of an augmented reality (AR) training application with conventional instructions for the Cube Navigation System (CNS), hypothesizing enhanced training with AR, leading to safer clinical usage. Methods An AR-tablet app was developed to train users puncturing with CNS. In a study, 34 medical students were divided into two groups: One trained with the AR-app, while the other used conventional instructions. After training, each participant executed 6 punctures on a phantom (204 in total) following a standardized protocol to identify and measure two potential CNS procedural user errors: (1) missing the coordinates specified and (2) altering the needle trajectory during puncture. Training performance based on train time and occurrence of procedural errors, as well as scores of User Experience Questionnaire (UEQ) for both groups, was compared. Results Training duration was similar between the groups. However, the AR-trained participants showed a 55.1% reduced frequency of the first procedural error (p > 0.05) and a 35.1% reduced extent of the second procedural error (p < 0.01) compared to the conventionally trained participants. UEQ scores favored the AR-training in five of six categories (p < 0.05). Conclusion The AR-app enhanced training performance and user experience over traditional methods. This suggests the potential of AR-training for navigation devices like the CNS, potentially increasing their safety, ultimately improving outcomes in percutaneous needle placements.
引用
收藏
页码:2411 / 2419
页数:9
相关论文
共 19 条
[1]  
Azimi E, 2018, IEEE ENG MED BIO, P4065, DOI 10.1109/EMBC.2018.8513387
[2]   Systematic review on the effectiveness of augmented reality applications in medical training [J].
Barsom, E. Z. ;
Graafland, M. ;
Schijven, M. P. .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2016, 30 (10) :4174-4183
[3]   Navigational Tools for Interventional Radiology and Interventional Oncology Applications [J].
Chehab, Monzer A. ;
Brinjikji, Waleed ;
Copelan, Alexander ;
Venkatesan, Aradhana M. .
SEMINARS IN INTERVENTIONAL RADIOLOGY, 2015, 32 (04) :416-427
[4]   Mixed reality navigation system for ultrasound-guided percutaneous punctures: a pre-clinical evaluation [J].
Davrieux, Carlos F. ;
Gimenez, Mariano E. ;
Gonzalez, Cristians A. ;
Ancel, Alexandre ;
Guinin, Maxime ;
Fahrer, Benedicte ;
Serra, Edgardo ;
Kwak, Jung-Myun ;
Marescaux, Jacques ;
Hostettler, Alexandre .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2020, 34 (01) :226-230
[5]   Computer assisted electromagnetic navigation improves accuracy in computed tomography guided interventions: A prospective randomized clinical trial [J].
Durand, Pierre ;
Moreau-Gaudry, Alexandre ;
Silvent, Anne-Sophie ;
Frandon, Julien ;
Chipon, Emilie ;
Medici, Maud ;
Bricault, Ivan .
PLOS ONE, 2017, 12 (03)
[6]   Comparison of accuracy between augmented reality/mixed reality techniques and conventional techniques for epidural anesthesia using a practice phantom model kit [J].
Hayasaka, Tatsuya ;
Kawano, Kazuharu ;
Onodera, Yu ;
Suzuki, Hiroto ;
Nakane, Masaki ;
Kanoto, Masafumi ;
Kawamae, Kaneyuki .
BMC ANESTHESIOLOGY, 2023, 23 (01)
[7]   Machine learning methods for automated technical skills assessment with instructional feedback in ultrasound-guided interventions [J].
Holden, Matthew S. ;
Xia, Sean ;
Lia, Hillary ;
Keri, Zsuzsanna ;
Bell, Colin ;
Patterson, Lindsey ;
Ungi, Tamas ;
Fichtinger, Gabor .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2019, 14 (11) :1993-2003
[8]   Metrics for 3D Rotations: Comparison and Analysis [J].
Huynh, Du Q. .
JOURNAL OF MATHEMATICAL IMAGING AND VISION, 2009, 35 (02) :155-164
[9]   Evaluation of the Access Cube Patient-Mounted Navigation System for CT-Guided Percutaneous Needle Placement-A Phantom Study [J].
Krammer, Lorenz ;
Hostettler, Rafael ;
Wetzel, Stephan .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2023, 34 (10) :1809-1814
[10]   Volumetric assessment of the periablational safety margin after thermal ablation of colorectal liver metastases [J].
Laimer, Gregor ;
Jaschke, Nikolai ;
Schullian, Peter ;
Putzer, Daniel ;
Eberle, Gernot ;
Solbiati, Marco ;
Solbiati, Luigi ;
Goldberg, S. Nahum ;
Bale, Reto .
EUROPEAN RADIOLOGY, 2021, 31 (09) :6489-6499