Application of hydraulic active test in hydraulic fault diagnosis of forging machine

被引:0
作者
Yang C. [1 ,2 ]
Zhao J. [1 ]
Yao C. [3 ]
Zhang R. [1 ]
Sun H. [1 ]
机构
[1] Hebei Provincial Key Laboratory of Heavy Machinery Fluid Power Transmission and Control, Yanshan University, Qinhuangdao
[2] Tangshan polytechnic College, Tangshan
[3] Key Laboratory of Industrial Computer Control Engineering of Hebei Province, Yanshan University, Qinhuangdao
来源
Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University | 2019年 / 40卷 / 02期
关键词
Fault diaghosis; Forging machine; Hydraulic active test; Hydraulic failure; Hydraulic system; Internal leakage; Leakage detection; Online detection;
D O I
10.11990/jheu.201708025
中图分类号
学科分类号
摘要
With the rapid development of hydraulic technology, the hydraulic system of a large forging machine is becoming increasingly complex. A fast and accurate approach for online detection is urgently needed to address large economic losses caused by continuous internal leakage of the hydraulic system. This study proposes a method of fault diagnosis for the forging machine based on hydraulic active test technology. A leakage model and an online detection model of an open hydraulic system are built. The total leakage of this hydraulic system is theoretically analyzed to derive the total sum of leakage of all control components of the main oil route and the leakage of a branch component. Furthermore, the detection method for the leakage of the main oil route control component and that of the branch component is theoretically analyzed. By conducting applied research on the deficiency in pressure of the hydraulic system of a 1 250 t forging machine, the researchers verified the effectiveness of the proposed method in detecting the internal leakage failure of the complex hydraulic system. © 2019, Editorial Department of Journal of HEU. All right reserved.
引用
收藏
页码:380 / 386
页数:6
相关论文
共 19 条
[1]  
Goharrizi A.Y., Sepehri N., A wavelet-based approach for external leakage detection and isolation from internal leakage in valve-controlled hydraulic actuators, IEEE Transactions on Industrial Electronics, 58, 9, pp. 4374-4384, (2011)
[2]  
Goharrizi A.Y., Sepehri N., Wu Y., Internal leakage diagnosis in hydraulic actuators using wavelet transforms, ASME 2009 Dynamic Systems and Control Conference, pp. 17-23, (2009)
[3]  
An L., Sepehri N., Leakage fault identification in a hydraulic positioning system using extended kalman filter, Proceedings of 2004 American Control Conference, pp. 3088-3093, (2004)
[4]  
Mahulkar V., Adams D.E., Derriso M., Derivative free filtering in hydraulic systems for fault identification, Control Engineering Practice, 19, 7, pp. 649-657, (2011)
[5]  
Kalyoncu M., Haydim M., Mathematical modelling and fuzzy logic based position control of an electrohydraulic servosystem with internal leakage, Mechatronics, 19, 6, pp. 847-858, (2009)
[6]  
Fu X., Liu B., Zhang Y., Et al., Fault diagnosis of hydraulic system in large forging hydraulic press, Measurement, 49, pp. 390-396, (2014)
[7]  
Tan H., Sepehri N., Parametric fault diagnosis for electrohydraulic cylinder drive units, IEEE Transactions on Industrial Electronics, 49, 1, pp. 96-106, (2002)
[8]  
An L., Sepehri N., Hydraulic actuator leakage fault detection using extended Kalman filter, International Journal of Fluid Power, 6, 1, pp. 41-51, (2005)
[9]  
Wu Z., Xu Z., Gao M., Trend prediction of hydraulic liquid leakage based on ES-LSSVM, Applied Mechanics and Materials, 137, pp. 440-444, (2012)
[10]  
Yao J., Yang G., Ma D., Internal leakage fault detection and tolerant control of single-rod hydraulic actuators, Mathematical Problems in Engineering, 2014, (2014)