Diagnostic performance of a point of care high-sensitivity cardiac troponin I assay and single measurement evaluation to rule out and rule in acute coronary syndrome

被引:3
作者
De Iuliis, Vincenzo [1 ]
Gabriele, Anna Rita [2 ]
De Santis, Francesca [1 ]
De Rugeriis, Roberta [1 ]
Di Quinzio, Luigi [2 ]
Aloisi, Steeve [2 ]
Rosati, Anna Carla [3 ]
Benvenuto, Manuela [3 ]
Fabiani, Donatello [3 ]
Chiatamone Ranieri, Sofia [1 ]
机构
[1] G Mazzini Civil Hosp, Dept Clin Pathol, Teramo, Italy
[2] G Mazzini Civil Hosp, Emergency Dept, Teramo, Italy
[3] G Mazzini Civil Hosp, Cardiol Div, Teramo, Italy
关键词
emergency department; acute myocardial infarction; point of care high sensitivity cardiac troponin assay; early rule out; early rule in;
D O I
10.1515/cclm-2024-0225
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: About 10 million individuals in USA presented annually in the emergency department (ED) with chest pain or with signs and symptoms of acute coronary syndrome (ACS). The advent of point of care (POC) devices, able to measure high sensitivity troponin, are a very interesting tool in the ED setting for its rapid turnaround time (<10 min). Methods: The present study evaluates the diagnostic performance of the Atellica VTLi (Siemens) in real life setting using the clinical data derived from integrated diagnoses of emergency room staff and cardiologist and in comparison with standard laboratory hs-cTnT assay (Cobas 8000, Elecsys, Roche). 966 patients admitted to the emergency department of "G. Mazzini Hospital" in Teramo, Italy, from July 27, 2022, through June 09, 2023, were enrolled. Results: The diagnostic performance of POC hs-cTnI was evaluated. An appropriate POC hs-cTnI threshold values <4 ng/L supplied a sensitivity and an NPV of 100 % (95 % CI: 99.5-100) in order to achieve rapid rule out for MI through a single measurement at patient presentation in the ED. Furthermore, a derivation POC hs-cTnI concentration >54 ng/L provided a specificity of 97.2 % (95 % CI: 95.9-98.1) and a PPV of 43.5 % (95 % CI: 40.3-46.7) for ruling in MI. Conclusions: This platform showed comparable diagnostic performance for myocardial infarction to the central laboratory. Our data suggest the possible use of the Atellica VTLi hs-cTnI POC assay either in emergency department of urban medical centre, either in rural hospital for triage and patient management.
引用
收藏
页码:2326 / 2334
页数:9
相关论文
共 26 条
  • [21] Discordance of cardiac troponin I assays on the point-of-care i-STAT and Architect assays from Abbott Diagnostics
    Singh, Jasbir
    Akbar, Muhammad S.
    Adabag, Selcuk
    [J]. CLINICA CHIMICA ACTA, 2009, 403 (1-2) : 259 - 260
  • [22] HEART DISEASE AND STROKE STATISTICS-2014 UPDATE: A REPORT FROM THE AMERICAN HEART ASSOCIATION
    Tarver, Talicia
    [J]. JOURNAL OF CONSUMER HEALTH ON THE INTERNET, 2014, 18 (02) : 209 - 209
  • [23] Thygesen K, 2012, EUR HEART J, V33, P2551, DOI [10.1016/j.gheart.2018.08.004, 10.1093/eurheartj/ehs184, 10.1161/CIR.0b013e31826e1058, 10.1016/j.gheart.2012.08.001, 10.1016/j.jacc.2012.08.001, 10.1016/j.clinbiochem.2012.10.036, 10.5603/KP.2018.0203]
  • [24] Safety and efficacy of the 0 h/3 h protocol for rapid rule out of myocardial infarction
    Wildi, Karin
    Nelles, Berit
    Twerenbold, Raphael
    Gimenez, Maria Rubini
    Reichlin, Tobias
    Singeisen, Helene
    Druey, Sophie
    Haaf, Philip
    Sabti, Zaid
    Hillinger, Petra
    Jaeger, Cedric
    Campodarve, Isabel
    Kreutzinger, Philip
    Puelacher, Christian
    Weidmann, Zoraida Moreno
    Gugala, Mathias
    Pretre, Gilles
    Doerflinger, Stephanie
    Wagener, Max
    Stallone, Fabio
    Freese, Michael
    Stelzig, Claudia
    Rentsch, Katharina
    Bassetti, Stefano
    Bingisser, Roland
    Osswald, Stefan
    Mueller, Christian
    [J]. AMERICAN HEART JOURNAL, 2016, 181 : 16 - 25
  • [25] Diagnostic performance of point-of-care and central laboratory cardiac troponin assays in an emergency department
    Wilke, Petra
    Masuch, Annette
    Fahron, Oliver
    Zylla, Stephanie
    Leipold, Tobias
    Petersmann, Astrid
    [J]. PLOS ONE, 2017, 12 (11):
  • [26] Clinical Laboratory Practice Recommendations for the Use of Cardiac Troponin in Acute Coronary Syndrome: Expert Opinion from the Academy of the American Association for Clinical Chemistry and the Task Force on Clinical Applications of Cardiac Bio-Markers of the International Federation of Clinical Chemistry and Laboratory Medicine
    Wu, Alan H. B.
    Christenson, Robert H.
    Greene, Dina N.
    Jaffe, Allan S.
    Kavsak, Peter A.
    Ordonez-Llanos, Jordi
    Apple, Fred S.
    [J]. CLINICAL CHEMISTRY, 2018, 64 (04) : 645 - 655