Diagnostic performance of a point of care high-sensitivity cardiac troponin I assay and single measurement evaluation to rule out and rule in acute coronary syndrome

被引:3
作者
De Iuliis, Vincenzo [1 ]
Gabriele, Anna Rita [2 ]
De Santis, Francesca [1 ]
De Rugeriis, Roberta [1 ]
Di Quinzio, Luigi [2 ]
Aloisi, Steeve [2 ]
Rosati, Anna Carla [3 ]
Benvenuto, Manuela [3 ]
Fabiani, Donatello [3 ]
Chiatamone Ranieri, Sofia [1 ]
机构
[1] G Mazzini Civil Hosp, Dept Clin Pathol, Teramo, Italy
[2] G Mazzini Civil Hosp, Emergency Dept, Teramo, Italy
[3] G Mazzini Civil Hosp, Cardiol Div, Teramo, Italy
关键词
emergency department; acute myocardial infarction; point of care high sensitivity cardiac troponin assay; early rule out; early rule in;
D O I
10.1515/cclm-2024-0225
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: About 10 million individuals in USA presented annually in the emergency department (ED) with chest pain or with signs and symptoms of acute coronary syndrome (ACS). The advent of point of care (POC) devices, able to measure high sensitivity troponin, are a very interesting tool in the ED setting for its rapid turnaround time (<10 min). Methods: The present study evaluates the diagnostic performance of the Atellica VTLi (Siemens) in real life setting using the clinical data derived from integrated diagnoses of emergency room staff and cardiologist and in comparison with standard laboratory hs-cTnT assay (Cobas 8000, Elecsys, Roche). 966 patients admitted to the emergency department of "G. Mazzini Hospital" in Teramo, Italy, from July 27, 2022, through June 09, 2023, were enrolled. Results: The diagnostic performance of POC hs-cTnI was evaluated. An appropriate POC hs-cTnI threshold values <4 ng/L supplied a sensitivity and an NPV of 100 % (95 % CI: 99.5-100) in order to achieve rapid rule out for MI through a single measurement at patient presentation in the ED. Furthermore, a derivation POC hs-cTnI concentration >54 ng/L provided a specificity of 97.2 % (95 % CI: 95.9-98.1) and a PPV of 43.5 % (95 % CI: 40.3-46.7) for ruling in MI. Conclusions: This platform showed comparable diagnostic performance for myocardial infarction to the central laboratory. Our data suggest the possible use of the Atellica VTLi hs-cTnI POC assay either in emergency department of urban medical centre, either in rural hospital for triage and patient management.
引用
收藏
页码:2326 / 2334
页数:9
相关论文
共 26 条
  • [1] Single High-Sensitivity Point-of-Care Whole-Blood Cardiac Troponin I Measurement to Rule Out Acute Myocardial Infarction at Low Risk
    Apple, Fred S.
    Smith, Stephen W.
    Greenslade, Jaimi H.
    Sandoval, Yader
    Parsonage, William
    Ranasinghe, Isuru
    Gaikwad, Niranjan
    Schulz, Karen
    Stephensen, Laura
    Schmidt, Christian W.
    Okeson, Brynn
    Cullen, Louise
    [J]. CIRCULATION, 2022, 146 (25) : 1918 - 1929
  • [2] Implementation of High-Sensitivity and Point-of-Care Cardiac Troponin Assays into Practice: Some Different Thoughts
    Apple, Fred S.
    Fantz, Corinne R.
    Collinson, Paul O.
    [J]. CLINICAL CHEMISTRY, 2021, 67 (01) : 70 - 78
  • [3] Novel high-sensitivity cardiac troponin I assay in patients with suspected acute coronary syndrome
    Chapman, Andrew R.
    Fujisawa, Takeshi
    Lee, Kuan Ken
    Andrews, Jack Patrick
    Anand, Atul
    Sandeman, Dennis
    Ferry, Amy V.
    Stewart, Stacey
    Marshall, Lucy
    Strachan, Fiona E.
    Gray, Alasdair
    Newby, David E.
    Shah, Anoop S. V.
    Mills, Nicholas L.
    [J]. HEART, 2019, 105 (08) : 616 - 622
  • [4] A Randomized Trial of a 1-Hour Troponin T Protocol in Suspected Acute Coronary Syndromes The Rapid Assessment of Possible Acute Coronary Syndrome in the Emergency Department With High-Sensitivity Troponin T Study (RAPID-TnT)
    Chew, Derek P.
    Lambrakis, Kristina
    Blyth, Andrew
    Seshadri, Anil
    Edmonds, Michael J. R.
    Briffa, Tom
    Cullen, Louise A.
    Quinn, Stephen
    Karnon, Jonathan
    Chuang, Anthony
    Nelson, Adam J.
    Wright, Deborah
    Horsfall, Matthew
    Morton, Erin
    French, John K.
    Papendick, Cynthia
    [J]. CIRCULATION, 2019, 140 (19) : 1543 - 1556
  • [5] Safety and efficacy of the European Society of Cardiology 0/1-hour algorithm for diagnosis of myocardial infarction: systematic review and meta-analysis
    Chiang, Cho-Han
    Chiang, Cho-Hung
    Lee, Gin Hoong
    Gi, Weng-Tein
    Wu, Yuan-Kun
    Huang, Sih-Shiang
    Yeo, Yee Hui
    Giannitsis, Evangelos
    Lee, Chien-Chang
    [J]. HEART, 2020, 106 (13) : 985 - 991
  • [6] Point-of-Care: Roadmap for Analytical Characterization and Validation of a High-Sensitivity Cardiac Troponin I Assay in Plasma and Whole Blood Matrices
    Christenson, Robert H.
    Frenk, Lisa D. S.
    de Graaf, Henk J.
    van Domburg, Trees S. Y.
    Wijnands, Frank P. G.
    Foolen, Helma W. J.
    Kemper, Danielle W. M.
    Bruinen, Anne L.
    Meijering, Bernadet D. M.
    Fonville, Judith M.
    de Theije, Femke K.
    [J]. JOURNAL OF APPLIED LABORATORY MEDICINE, 2022, 7 (04) : 971 - 988
  • [7] Collet JP, 2021, REV ESP CARDIOL, V74, DOI [10.1093/eurheartj/ehaa575, 10.1016/j.rec.2021.05.002]
  • [8] Point-of-care testing with high-sensitivity cardiac troponin assays: the challenges and opportunities
    Cullen, Louise
    Collinson, Paul O.
    Giannitsis, Evangelos
    [J]. EMERGENCY MEDICINE JOURNAL, 2022, 39 (11) : 861 - 866
  • [9] Early Rule-Out and Rule-In Strategies for Myocardia Infarction
    Cullen, Louise A.
    Mills, Nicholas L.
    Mahler, Simon
    Body, Richard
    [J]. CLINICAL CHEMISTRY, 2017, 63 (01) : 129 - 139
  • [10] Unstable Angina in the Era of Cardiac Troponin Assays with Improved Sensitivity-A Clinical Dilemma
    Eggers, Kai M.
    Jernberg, Tomas
    Lindahl, Bertil
    [J]. AMERICAN JOURNAL OF MEDICINE, 2017, 130 (12) : 1423 - +