Grid-connected control strategy of photovoltaic inverter based on double sequence feed-forward decoupling

被引:0
|
作者
Yang H. [1 ]
Song G. [1 ]
Teng F. [1 ]
Yang Z. [1 ]
Chen Y. [1 ]
机构
[1] School of Electrical Engineering, Guangxi University, Nanning
来源
Taiyangneng Xuebao/Acta Energiae Solaris Sinica | 2021年 / 42卷 / 01期
关键词
Coordinates transformation; Dead zone; Feed-forward decoupling; PV grid-connected inverter; Repetitive control;
D O I
10.19912/j.0254-0096.tynxb.2019-1065
中图分类号
学科分类号
摘要
The current quality in PV grid-connected inverters is deteriorated due to interference of grid voltage and couplings between the phases in dq frame, especially under the unbalanced grid conditions. Therefore, a positive and negative sequence feed-forward technique was proposed for a alternative solution. The double synchronous reference frame is utilized to eliminate the negative-sequence component and extract the positive-sequence component for decoupling control. In order to avoid dead-time effect, compound control of repetitive controller with PI controller is used as a current harmonic compensator. The validity of the proposed control scheme is demonstrated through simulations. Experimental results of decreasing the harmonic content of grid-connected current also shows the effectiveness. © 2021, Solar Energy Periodical Office Co., Ltd. All right reserved.
引用
收藏
页码:77 / 84
页数:7
相关论文
共 16 条
  • [1] BLAABJERG F, TEODORESCU R, LISERRE M, Et al., Overview of control and grid synchronization for distributed power generation systems, IEEE transactions on industrial electronics, 53, 5, pp. 1398-1409, (2006)
  • [2] ROCABERT J, LUNA A, BLAABJERG F, Et al., Control of power converters in AC microgrids, IEEE transactions on power electronics, 27, 11, pp. 4734-4749, (2012)
  • [3] TAUL M. G, WANG X, DAVARI P, Et al., An overview of assessment methods for synchronization stability of grid-connected converters under severe symmetrical grid faults, IEEE transactions on power electronics, 34, 10, pp. 9655-9670, (2019)
  • [4] XU J M, XIE S J, ZHANG B F., Overview of current control techniques for grid-connected inverters with LCL filters in distributed power generation systems, Proceedings of the CSEE, 35, 16, pp. 4153-4166, (2015)
  • [5] LI D H, TIAN L Y, YAO L L, Et al., Research on control strategy of grid-connected inverter under unbalanced voltage, Acta energiae solaris sinica, 40, 9, pp. 2594-2600, (2019)
  • [6] WANG X H, PIAN S H, ZHANG J J., Research on complex controller and its control cluster for grid-connected inverters in non-ideal power grid, Acta energiae solaris sinica, 40, 2, pp. 538-548, (2019)
  • [7] BAO C L, RUAN X B, WANG X H, Et al., Closed-loop parameter design of LCL grid-connected inverter based on PI regulator and capacitance current feedback active damping, Proceedings of the CSEE, 32, 25, pp. 133-142, (2012)
  • [8] WANG Y, GAO N, LUO Y H, Et al., Research on dead-time SPWM control of three-phase three-level grid-connected inverter, Proceedings of the CSEE, 31, 21, pp. 70-75, (2011)
  • [9] YANG Y, ZHOU K, WANG H, Et al., Analysis and mitigation of dead-time harmonics in the single-phase full-bridge PWM converter with repetitive controllers, IEEE transactions on industry applications, 54, 5, pp. 5343-5354, (2018)
  • [10] WU Y Y, XIE S J, KAN J R, Et al., Voltage feedforward control strategy of LCL grid-connected inverter with inverter side current feedback, Proceedings of the CSEE, 33, 6, pp. 54-60, (2013)