The effectiveness of vapor-injection for an inverter air-source heat pump compared with vapor-return

被引:2
作者
Wang, Jijin [1 ,2 ]
Guo, Jianxiang [1 ]
Qv, Dehu [3 ]
Zhang, Linyang [1 ]
Liu, Na [1 ]
Ni, Long [2 ]
机构
[1] Qingdao Univ Technol, Sch Environm & Municipal Engn, Qingdao, Peoples R China
[2] Harbin Inst Technol, Sch Architecture & Design, Key Lab Cold Reg Urban & Rural Human Settlement En, Minist Ind & Informat Technol, Harbin 150090, Peoples R China
[3] Lanzhou Univ Technol, Sch Civil Engn, Dept Bldg Environm & Energy Applicat Engn, Lanzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Air -source heat pump; The effectiveness of vapor -injection; Heating performance; Relative entropy reduction; Vapor; -return; FLASH-TANK; PERFORMANCE; SYSTEM; CYCLE; OPTIMIZATION; COMPRESSOR; PRESSURE; R1234YF; DESIGN; R134A;
D O I
10.1016/j.applthermaleng.2024.122827
中图分类号
O414.1 [热力学];
学科分类号
摘要
The vapor-injection assisted with air-source heat pump (ASHP) has become one of the focuses in the last decade. It can improve the heating performance of the ASHP system in low ambient temperatures by experiments. However, the vapor-injection is ineffective in moderate ambient temperatures owing to the high pressure of the compressor intermediate chamber. On the other side, the effectiveness of vapor-injection is rarely discussed. Based on experiments and the thermodynamic analysis method, this paper proposes an inverter air-source heat pump (IASHP) with vapor-injection and vapor-return. With the scope from -20 degrees C to7.0 degrees C for ambient temperature, it focuses on the heating performance of the prototype with different compressor frequencies for both vapor-injection and vapor-return modes. Moreover, the effectiveness of vapor-injection is discussed. The results show that the vapor-injection is superior to vapor-return for improving the heating performance of the prototype. Not only does the vapor-injection significantly affect refrigerant mass flow rate, but it also makes the relative entropy reduction (RER) of the compressor outlet decrease by 0.025-0.03 kJ/(kg & sdot;K). In the case of ambient temperature at -4.0 degrees C, the vapor-injection improves by 6.6 % and 3.4 % for heating capacity and COP of the prototype. Besides, the effectiveness of vapor-injection lies in the RER of the compressor outlet, which is suitable for vapor-injection using different refrigerants.
引用
收藏
页数:16
相关论文
共 39 条
  • [1] Performance investigation of some hydro-fluorocarbon refrigerants with low global warming as substitutes to R134a in refrigeration systems
    Bolaji, B. O.
    Huan, Z.
    [J]. JOURNAL OF ENGINEERING THERMOPHYSICS, 2014, 23 (02) : 148 - 157
  • [2] Theoretical analysis of internal heat exchanger in transcritical CO2 heat pump systems and its experimental verification
    Cao, Feng
    Wang, Yikai
    Ye, Zuliang
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 106 : 506 - 516
  • [3] Heating performance comparison of R410A and its substitutions in air-to-water heat pumps with vapor injection
    Chen, Xiaoning
    Yang, Jingye
    Liu, Cichong
    Chen, Jiangping
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 96 : 78 - 87
  • [4] Performance evaluation of a novel heat pump system for drying with EVI-compressor driven precooling and reheating
    Cheng, Jia-Hao
    Cao, Xiang
    Shao, Liang-Liang
    Zhang, Chun-Lu
    [J]. ENERGY, 2023, 278
  • [5] Carbon reduction analysis of electric heat pumps in carbon neutrality in China
    Dong, Shihao
    Zhao, Hengyi
    Zheng, Yuanbo
    Ni, Long
    [J]. SUSTAINABLE CITIES AND SOCIETY, 2023, 97
  • [6] Experiment study on startup characteristics and operation performance of PV/T solar assisted heat pump water heater system driven by direct current variable frequency compressor
    Dong, Zhang
    Su, Xinyue
    Liu, Pengfei
    Hui, Bo
    Hou, Gang
    Liu, Chunyang
    Xu, Baorui
    Zhang, Tao
    An, Zhoujian
    [J]. SOLAR ENERGY, 2023, 263
  • [7] Comparison of the heating performance of air-source heat pumps using various types of refrigerant injection
    Heo, Jaehyeok
    Jeong, Min Woo
    Baek, Changhyun
    Kim, Yongchan
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (02): : 444 - 453
  • [8] Experiments of advanced centrifugal heat pump with supply temperature up to 100 °C using low-GWP refrigerant R1233zd(E)
    Jiang, Jiatong
    Hu, Bin
    Wang, R. Z.
    Ge, Tianshu
    Liu, Hua
    Zhang, Zhiping
    Zhou, Yu
    [J]. ENERGY, 2023, 263
  • [9] Jiang Y., 2021, CHIN HEAT PUMP IND A
  • [10] Numerical study of the effects of injection-port design on the heating performance of an R134a heat pump with vapor injection used in electric vehicles
    Jung, Jongho
    Jeon, Yongseok
    Lee, Hoseong
    Kim, Yongchan
    [J]. APPLIED THERMAL ENGINEERING, 2017, 127 : 800 - 811