Highly Sensitive Colorimetric Detection of Listeria monocytogenes by Using Gold Nanoparticles Based on Magnetic Metal-Organic Framework Separation

被引:0
作者
Du J. [1 ]
Chen X. [1 ]
Liu K. [1 ]
Liu J. [1 ]
Luo P. [2 ]
Liang D. [3 ]
Bai Y. [1 ]
机构
[1] College of Food and Bioengineering, Henan Key Laboratory of Cold Chain Food Quality and Safety Control, Zhengzhou University of Light Industry, Zhengzhou
[2] NHC Key Laboratory of Food Safety Risk Assessment, Chinese Academy of Medical Science Research Unit (2019RU014), China National Center for Food Safety Risk Assessment, Beijing
[3] Applied Nutrition I, China National Center for Food Safety Risk Assessment, Beijing
来源
Shipin Kexue/Food Science | 2023年 / 44卷 / 05期
关键词
colorimetric assay; gold nanoparticles; Listeria monocytogenes; magnetic separation;
D O I
10.7506/spkx1002-6630-20220316-179
中图分类号
学科分类号
摘要
In this study, magnetic metal organic framework composites as capture probe and immunofunctionalized gold nanoparticles as signal probe were used to develop a rapid colorimetric method for the detection of Listeria monocytogenes. Under optimal conditions, the visual detection limit for L. monocytogenes was 1.2 × 103 CFU/mL. The results of ultraviolet spectroscopy showed a good linear relationship in the range of 1.2 × 101‒1.2 × 108 CFU/mL (Y = 0.519 ‒ 0.043X, R2 = 0.978), the detection limit was as low as 0.45 CFU/mL, and the intra-batch coefficient of variation of all concentration gradients was between 0.31% and 1.30%. The recoveries for spiked chicken breast were 91.1%‒108.7% with coefficient of variation less than 7.4%, and the result was consistent with that of the plate counting method. In conclusion, the proposed assay is rapid, accurate sensitive, and highly applicable to the detection of foodborne pathogens. © 2023 Chinese Chamber of Commerce. All rights reserved.
引用
收藏
页码:360 / 367
页数:7
相关论文
共 33 条
[1]  
ZHAO Y, LI Y X, JIANG K, Et al., Rapid detection of Listeria monocytogenes in food by biofunctionalized magnetic nanoparticle based on nuclear magnetic resonance, Food Control, 71, pp. 110-116, (2017)
[2]  
NOORDHOUT C M, DEVLEESSCHAUWER B, ANGULO F J, Et al., The global burden of listeriosis: a systematic review and meta-analysis, Lancet Infectious Diseases, 14, 11, pp. 1073-1082, (2014)
[3]  
European Food Safety Authority European Centre for Disease Prevention and Control, The European Union One Health 2019 Zoonoses Report, EFSA Journal, 19, 2, (2021)
[4]  
GUO Y Y, ZHAO C, LIU Y S, Et al., A novel fluorescence method for the rapid and effective detection of Listeria monocytogenes using aptamer-conjugated magnetic nanoparticles and aggregation-induced emission dots, The Analyst, 145, 11, pp. 3857-3863, (2020)
[5]  
LI Q R, ZHANG S, CAI Y X, Et al., Rapid detection of Listeria monocytogenes using fluorescence immunochromatographic assay combined with immunomagnetic separation technique, International Journal of Food Science and Technology, 52, 7, pp. 1559-1566, (2017)
[6]  
MAGALHAES R, MENA C, FERREIRA V, Et al., Traditional methods of analysis for Listeria monocytogenes, Methods in molecular biology, 2220, pp. 3-16, (2021)
[7]  
BLAZKOVA M, KARAMONOVA L, FUKAL L, Et al., Listeria monocytogenes-nebezpečný patogen a jeho detekce v potravinách, Chemicke Listy, 99, pp. 467-473, (2005)
[8]  
WANG S Q, DENG W F, YANG T K, Et al., Copper-based metal-organic framework nanoparticles with peroxidase-like activity for sensitive colorimetric detection of Staphylococcus aureus, ACS Applied Materials & Interfaces, 9, 29, pp. 24440-24445, (2017)
[9]  
TIAN Y M, BU T, ZHANG M, Et al., Metal-polydopamine framework based lateral flow assay for high sensitive detection of tetracycline in food samples, Food Chemistry, 339, (2021)
[10]  
ZHANG X, ZHOU J, ZHANG C D, Et al., Rapid detection of Enterobacter cloacae by immunomagnetic separation and a colloidal gold-based immunochromatographic assay, RSC Advances, 6, (2016)