Quantitative assessment of intertarget position variations based on 4D-CT and 4D-CBCT simulations in single-isocenter multitarget lung stereotactic body radiation therapy

被引:0
作者
Zhang, Siyu [1 ]
Guo, Chang [1 ]
Xu, Jun [1 ]
Qian, Pudong [1 ]
Guo, Jiali [2 ]
Liu, Tingting [1 ]
Wu, Yifan [1 ]
Hong, Jun [3 ]
Wang, Qi [1 ]
He, Xia [1 ]
Sun, Li [1 ]
机构
[1] Nanjing Med Univ, Affiliated Canc Hosp, Dept Radiotherapy, Jiangsu Canc Hosp, Nanjing 210009, Peoples R China
[2] Dantu Peoples Hosp, Dept Radiat Oncol, Maanshan 243100, Anhui, Peoples R China
[3] Nanjing Med Univ, Dept Radiat Oncol, Affiliated Huaian Peoples Hosp 1, Huaian 223300, Jiangsu, Peoples R China
关键词
Intertarget position variation; Multiple targets; Lung SBRT; 4D-CBCT; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; MOTION; VARIABILITY; CANCER; RADIOTHERAPY; MARGINS; CT;
D O I
10.1007/s00432-024-05836-w
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
BackgroundIn single-isocenter multitarget stereotactic body radiotherapy (SBRT), geometric miss risks arise from uncertainties in intertarget position. However, its assessment is inadequate, and may be interfered by the reconstructed tumor position errors (RPEs) during simulated CT and cone beam CT (CBCT) acquisition. This study aimed to quantify intertarget position variations and assess factors influencing it.MethodsWe analyzed data from 14 patients with 100 tumor pairs treated with single-isocenter SBRT. Intertarget position variation was measured using 4D-CT simulation to assess the intertarget position variations (Delta D) during routine treatment process. Additionally, a homologous 4D-CBCT simulation provided RPE-free comparison to determine the impact of RPEs, and isolating purely tumor motion induced Delta D to evaluate potential contributing factors.ResultsThe median Delta D was 4.3 mm (4D-CT) and 3.4 mm (4D-CBCT). Variations exceeding 5 mm and 10 mm were observed in 31.1% and 5.5% (4D-CT) and 20.4% and 3.4% (4D-CBCT) of fractions, respectively. RPEs necessitated an additional 1-2 mm safety margin. Intertarget distance and breathing amplitude variability showed weak correlations with variation (Rs = 0.33 and 0.31). The Delta D differed significantly by locations (upper vs. lower lobe and right vs. Left lung). Notably, left lung tumor pairs exhibited the highest risk.ConclusionsThis study provide a reliable way to assess intertarget position variation by using both 4D-CT and 4D-CBCT simulation. Consequently, single-isocenter SBRT for multiple lung tumors carries high risk of geometric miss. Tumor motion and RPE constitute a substantial portion of intertarget position variation, requiring correspondent strategies to minimize the intertarget uncertainties.
引用
收藏
页数:10
相关论文
共 26 条
[1]   QUANTIFYING INTERFRACTION AND INTRAFRACTION TUMOR MOTION IN LUNG STEREOTACTIC BODY RADIOTHERAPY USING RESPIRATION-CORRELATED CONE BEAM COMPUTED TOMOGRAPHY [J].
Bissonnette, Jean-Pierre ;
Franks, Kevin N. ;
Purdie, Thomas G. ;
Moseley, Douglas J. ;
Sonke, Jan-Jakob ;
Jaffray, David A. ;
Dawson, Laura A. ;
Bezjak, Andrea .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03) :688-695
[2]   Geographic miss of lung tumours due to respiratory motion: a comparison of 3D vs 4D PET/CT defined target volumes [J].
Callahan, Jason ;
Kron, Tomas ;
Siva, Shankar ;
Simoens, Nathalie ;
Edgar, Amanda ;
Everitt, Sarah ;
Schneider, Michal E. ;
Hicks, Rodney J. .
RADIATION ONCOLOGY, 2014, 9
[3]   The effect of irregular breathing patterns on internal target volumes in four-dimensional CT and cone-beam CT images in the context of stereotactic lung radiotherapy [J].
Clements, N. ;
Kron, T. ;
Franich, R. ;
Dunn, L. ;
Roxby, P. ;
Aarons, Y. ;
Chesson, B. ;
Siva, S. ;
Duplan, D. ;
Ball, D. .
MEDICAL PHYSICS, 2013, 40 (02)
[4]   Respiration-correlated spiral CT: A method of measuring respiratory-induced anatomic motion for radiation treatment planning [J].
Ford, EC ;
Mageras, GS ;
Yorke, E ;
Ling, CC .
MEDICAL PHYSICS, 2003, 30 (01) :88-97
[5]   Local consolidative therapy versus maintenance therapy or observation for patients with oligometastatic non-small-cell lung cancer without progression after first-line systemic therapy: a multicentre, randomised, controlled, phase 2 study [J].
Gomez, Daniel R. ;
Blumenschein, George R., Jr. ;
Lee, J. Jack ;
Hernandez, Mike ;
Ye, Rong ;
Camidge, D. Ross ;
Doebele, Robert C. ;
Skoulidis, Ferdinandos ;
Gaspar, Laurie E. ;
Gibbons, Don L. ;
Karam, Jose A. ;
Kavanagh, Brian D. ;
Tang, Chad ;
Komaki, Ritsuko ;
Louie, Alexander V. ;
Palma, David A. ;
Tsao, Anne S. ;
Sepesi, Boris ;
William, William N. ;
Zhang, Jianjun ;
Shi, Qiuling ;
Wang, Xin Shelley ;
Swisher, Stephen G. ;
Heymach, John V. .
LANCET ONCOLOGY, 2016, 17 (12) :1672-1682
[6]   Consolidative Radiotherapy for Limited Metastatic Non-Small-Cell Lung Cancer A Phase 2 Randomized Clinical Trial [J].
Iyengar, Puneeth ;
Wardak, Zabi ;
Gerber, David E. ;
Tumati, Vasu ;
Ahn, Chul ;
Hughes, Randall S. ;
Dowell, Jonathan E. ;
Cheedella, Naga ;
Nedzi, Lucien ;
Westover, Kenneth D. ;
Pulipparacharuvil, Suprabha ;
Choy, Hak ;
Timmerman, Robert D. .
JAMA ONCOLOGY, 2018, 4 (01)
[7]   Marker-based quantification of interfractional tumor position variation and the use of markers for setup verification in radiation therapy for esophageal cancer [J].
Jin, Peng ;
van der Horst, Astrid ;
de Jong, Rianne ;
van Hooft, Jeanin E. ;
Kamphuis, Martijn ;
van Wieringen, Niek ;
Machiels, Melanie ;
Bel, Arjan ;
Hulshof, Maarten C. C. M. ;
Alderliesten, Tanja .
RADIOTHERAPY AND ONCOLOGY, 2015, 117 (03) :412-418
[8]   Analysis of the advantage of individual PTVs defined on axial 3D CT and 4D CT images for liver cancer [J].
Li, Fengxiang ;
Li, Jianbin ;
Xing, Jun ;
Zhang, Yingjie ;
Fan, Tingyong ;
Xu, Min ;
Shang, Dongping ;
Liu, Tonghai ;
Song, Jinlong .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (06) :62-71
[9]  
Li Xiang, 2018, Int J Med Phys Clin Eng Radiat Oncol, V7, P173, DOI 10.4236/ijmpcero.2018.72015
[10]   Using 4DCBCT simulation and guidance to evaluate inter-fractional tumor variance during SABR for lung tumor within the lower lobe [J].
Li, Yi ;
Wu, Wenjing ;
He, Ruixin ;
Lu, Yongkai ;
Zhang, Yuemei ;
Wang, Long ;
Zhang, Xiaozhi .
SCIENTIFIC REPORTS, 2021, 11 (01)