Transient Synchronization Stability Analysis of Voltage Source Converters: A Review

被引:0
作者
Zhang Y. [1 ]
Cai X. [1 ]
Zhang C. [1 ]
Lyu J. [1 ]
Li Y. [2 ]
机构
[1] Laboratory of Control of Power Transmission and Conversion, Shanghai Jiao Tong University, Ministry of Education, Minhang District, Shanghai
[2] State Key Laboratory of HVDC, Electric Power Research Institute, China Southern Power Grid, Guangzhou
来源
Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering | 2021年 / 41卷 / 05期
基金
中国国家自然科学基金;
关键词
Large disturbance; Loss of synchronization; Phase-locked loop; Synchronization mechanism; Synchronization stability; Transient stability; Voltage source converter (VSC);
D O I
10.13334/j.0258-8013.pcsee.201673
中图分类号
学科分类号
摘要
With the increase of the penetration of renewable energy, the influence of grid connected converter on the dynamic and stability of the power grid is becoming severe, such as low inertia and wide-band oscillation. This paper discussed the problem of transient synchronization stability (TSS) which is closely related to the nonlinear dynamics of the synchronization unit of the converters. Firstly, the inherent relationship between the TSS of the VSC and angle stability of synchronous generator (SG) had been revealed by investigating the similarity of synchronization mechanism between VSC and SG. Secondly, the instability mechanism, analysis method and stabilization control regarding the TSS issue had been comprehensively reviewed. Thirdly, the challenge of TSS studying was summarized, the generally application-oriented stabilization method was proposed, and further synchronization issue for future research was prospected. The general method of TSS is concluded in this paper, which provides reference to applications and future research. © 2021 Chin. Soc. for Elec. Eng.
引用
收藏
页码:1687 / 1701
页数:14
相关论文
共 63 条
[1]  
China 2050 high Renewable energy penetration scenario and roadmap study, (2015)
[2]  
XU Zheng, Three technical challenges faced by power grids with high proportion of non-synchronous machine sources, Southern Power System Technology, 14, 2, pp. 1-9, (2020)
[3]  
LI Mingjie, YU Zhao, XU Tao, Et al., Study of complex oscillation caused by renewable energy integration and its solution, Power System Technology, 41, 4, pp. 1035-1042, (2017)
[4]  
JIANG Qirong, WANG Liang, XIE Xiaorong, Study on oscillations of power-electronized power system and their mitigation schemes, High Voltage Engineering, 43, 4, pp. 1057-1066, (2017)
[5]  
HU Jiabing, YUAN Xiaoming, CHENG Shijie, Multi-time Scale transients in power-electronized power systems considering multi-time scale switching control schemes of power electronics apparatus, Proceedings of the CSEE, 39, 18, pp. 5457-5467, (2019)
[6]  
AMIN M, MOLINAS M., Small-signal stability assessment of power electronics based power systems: a discussion of impedance-and eigenvalue-based methods, IEEE Transactions on Industry Applications, 53, 5, pp. 5014-5030, (2017)
[7]  
ERLICH I, SHEWAREGA F, ENGELHARDT S, Et al., Effect of wind turbine output current during faults on grid voltage and the transient stability of wind parks, Proceedings of the 2009 IEEE Power & Energy Society General Meeting, pp. 1-8, (2009)
[8]  
GOKSU O, TEODORESCU R, BAK C L, Et al., Instability of wind turbine converters during current injection to low voltage grid faults and PLL frequency based stability solution, IEEE Transactions on Power Systems, 29, 4, pp. 1683-1691, (2014)
[9]  
ZHU Shu, LIU Kaipei, QIN Liang, Et al., Analysis of transient stability of power electronics dominated power system: an overview, Proceedings of the CSEE, 37, 14, pp. 3948-3962, (2017)
[10]  
HUANG Meng, PENG Yu, TSE C K, Et al., Bifurcation and large-signal stability analysis of three-phase voltage source converter under grid voltage dips, IEEE Transactions on Power Electronics, 32, 11, pp. 8868-8879, (2017)