Post-damage recovery of substandard RC columns by CFRPs

被引:3
|
作者
Yurdakul, Ozgur [1 ]
Vnenk, Petr [2 ]
Routil, Ladislav [1 ]
Culek, Bohumil [1 ]
Avsar, Ozgur [3 ]
机构
[1] Univ Pardubice, Pardubice, Czech Republic
[2] Sprava Zeleznic, Prague, Czech Republic
[3] Eskisehir Tech Univ, Eskisehir, Turkiye
关键词
Substandard; Low-strength concrete; Plain round bar; Column; Repair; Bond-Slip; REINFORCED-CONCRETE COLUMNS; LOW-STRENGTH CONCRETE; AXIAL-COMPRESSION; REPAIR; FRP; MODEL; PERFORMANCE; BEHAVIOR; SHEETS;
D O I
10.1016/j.engstruct.2024.117806
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cyclic response of substandard reinforced concrete (RC) columns and structural repair of pre -damaged columns by carbon -fiber -reinforced polymers (CFRPs) were investigated through combination of experimental and advanced numerical modeling methods. The specimens, representing typical RC columns in substandard buildings, were constructed from low -strength concrete, plain round bars, and nonconforming reinforcement details. The key parameters under investigation included the lap -splice, hook detail in the longitudinal reinforcement, and axial load ratio. First, the RC columns were subjected to cyclic loading until the attainment of their heavy damage state. The failure mode was dominated by the flexural response alongside significant reinforcement slip and axial damage, involving concrete crushing and reinforcement buckling. Subsequently, the severe cracks and concrete damage were repaired by the externally wrapped CFRP sheets. The former loadcarrying capacities of the repaired RC columns were recovered. The damage formation in the concrete and reinforcement was transferred to CFRP sheets. The final failure mode was characterized by local deformations in the CFRP, with minimal damage observed in the concrete and reinforcement bars. Furthermore, the numerical solution effectively reproduced the nonlinear behavior of the as -built specimens. The crack patterns and capacities observed in the numerical solutions align with the responses observed in the experimental tests.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Seismic repair of captive-column damage with CFRPs in substandard RC frames
    Tunaboyu, Onur
    Avsar, Ozgur
    STRUCTURAL ENGINEERING AND MECHANICS, 2017, 61 (01) : 1 - 13
  • [2] Seismic rehabilitation of substandard RC columns with partially deteriorated concrete using CFRP composites
    Hou, Dongxu
    Wu, Zhimin
    Zheng, Jianjun
    Cui, Yao
    COMPUTERS AND CONCRETE, 2015, 15 (01) : 1 - 20
  • [3] External steel ties and CFRP jacketing effects on seismic performance and failure mechanisms of substandard rectangular RC columns
    Ghatte, Hamid Farrokh
    COMPOSITE STRUCTURES, 2020, 248
  • [4] Rapid retrofit of substandard short RC columns with buckled longitudinal bars using CFRP jacketing
    Moretti, Marina L.
    EARTHQUAKES AND STRUCTURES, 2023, 24 (02) : 97 - 109
  • [5] Application of Hybrid Simulation for Collapse Assessment of Post-Earthquake CFRP-Repaired RC Columns
    Hashemi, M. Javad
    Al-Ogaidi, Yassamin
    Al-Mahaidi, Riadh
    Kalfat, Robin
    Tsang, Hing-Ho
    Wilson, John L.
    JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (01)
  • [6] Axial loading capacity of concrete-jacketed RC columns with pre- and post-corrosion damage
    Zhao, Yuxi
    Zhang, Dawei
    Shen, Shijun
    Ueda, Tamon
    STRUCTURAL CONCRETE, 2016, 17 (03) : 355 - 364
  • [7] Hybrid Use of Externally Embedded FRP Reinforcement for Seismic Retrofitting of Substandard RC Columns
    Seyhan, Engin C.
    Goksu, Caglar
    Saribas, Ilyas
    Ilki, Alper
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2023, 27 (03)
  • [8] Post-Damage Repair of Prestressed Concrete Girders
    Chris Ramseyer
    Thomas H.-K. Kang
    International Journal of Concrete Structures and Materials, 2012, 6 : 199 - 207
  • [9] Rehabilitation of Corrosion-Damaged Substandard RC Columns Using FRP Sheets
    Kalyoncuoglu, Aras
    Ghaffari, Pooya
    Goksu, Cagier
    Ilki, Alper
    ADVANCES IN CIVIL INFRASTRUCTURE ENGINEERING, PTS 1 AND 2, 2013, 639-640 : 1096 - 1103
  • [10] Seismic Performance of Substandard RC Columns Retrofitted with Sprayed GFRM
    Kian, Nima
    Demir, Ugur
    Demir, Cem
    Marasli, Muhammed
    Ilki, Alper
    10TH INTERNATIONAL CONFERENCE ON FRP COMPOSITES IN CIVIL ENGINEERING (CICE 2020/2021), 2022, 198 : 1317 - 1328