Modified Jiles-Atherton Model-Based System Matrix Generation Method for Magnetic Particle Imaging

被引:8
|
作者
Li, Yimeng [1 ,2 ,3 ]
Li, Guanghui [1 ,2 ,3 ]
Zhang, Peng [4 ]
An, Yu [1 ,2 ,3 ]
Hui, Hui [3 ]
Tian, Jie [1 ,2 ,3 ]
机构
[1] Beihang Univ, Sch Engn Med, Beijing 100191, Peoples R China
[2] Beihang Univ, Sch Biol Sci & Med Engn, Beijing 100191, Peoples R China
[3] Chinese Acad Sci, Inst Automat, CAS Key Lab Mol Imaging, Beijing Key Lab Mol Imaging, Beijing 100190, Peoples R China
[4] Chinese Acad Med Sci & Peking Union Med Coll, Peking Union Med Coll Hosp, Beijing 100190, Peoples R China
基金
中国国家自然科学基金;
关键词
Coils; Magnetization; Electromagnetics; Image reconstruction; Voltage measurement; Mathematical models; Biomedical imaging; Magnetic nanoparticle; magnetic particle imaging (MPI); modified Jiles-Atherton (MJA) model; system matrix (SM); NANOPARTICLE; RESOLUTION; SIGNAL;
D O I
10.1109/TIM.2024.3381694
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The system matrix (SM) is an important component of magnetic particle imaging (MPI) because it describes the mapping between the particle concentration and voltage signal. The acquisition of SM predominantly relies on measurement-based calibration. However, the measurement procedure is time-consuming and susceptible to noise interference, leading to a decrease in reconstruction quality. The need for measuring the SM is because existing MPI forward physical process models are not sufficiently accurate for model-based SM generation. To address this problem, we propose a model-based SM generation method based on the modified Jiles-Atherton (MJA) for accurate and fast modeling of the MPI forward physical process (MJA-SMGM). In the proposed method, the MJA accurately describes the dynamic magnetization responses of superparamagnetic iron-oxide (SPIO) nanoparticles. The MJA model considers the relaxation effect to improve accuracy and reduce complexity to accelerate solving. Additionally, time-harmonic electromagnetic field analysis for inhomogeneity and the transfer function of the receive signal chain are included for SM generation. The proposed MJA-SMGM method can achieve fast and accurate SM generation, thereby improving the quality of reconstructed images. Compared to the complex Fokker-Planck method, MJA-SMGM is approximately 70 times faster and reduces error by 30.2% according to the results of homemade MPI scanner experiments. Additionally, the proposed method improves image quality by 2.2 times in terms of the signal-to-noise ratio. These results indicate that MJA-SMGM has the potential to improve the applicability of SM methods in various MPI scanners.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 40 条
  • [1] Modified Jiles-Atherton Model for Dynamic Magnetization in X-Space Magnetic Particle Imaging
    Li, Yimeng
    Hui, Hui
    Zhang, Peng
    Zhong, Jing
    Yin, Lin
    Zhang, Haoran
    Zhang, Bo
    An, Yu
    Tian, Jie
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2023, 70 (07) : 2035 - 2045
  • [2] A Circuit-Based Formulation for Soft Magnetic Materials Using the Jiles-Atherton Model
    Kanakgiri, Krishna
    Bhardwaj, Dhruv Ishan
    Ram, Boggavarapu Sai
    Kulkarni, Shrikrishna V.
    IEEE TRANSACTIONS ON MAGNETICS, 2024, 60 (10)
  • [3] Computational Problems Connected with Jiles-Atherton Model of Magnetic Hysteresis
    Szewczyk, Roman
    RECENT ADVANCES IN AUTOMATION, ROBOTICS AND MEASURING TECHNIQUES, 2014, 267 : 275 - 283
  • [4] Parameter estimation of extended Jiles-Atherton hysteresis model based on ISFLA
    Zou, Mi
    IET ELECTRIC POWER APPLICATIONS, 2020, 14 (02) : 212 - 219
  • [5] Equilibrium Model With Anisotropy for Model-Based Reconstruction in Magnetic Particle Imaging
    Maass, Marco
    Kluth, Tobias
    Droigk, Christine
    Albers, Hannes
    Scheffler, Konrad
    Mertins, Alfred
    Knopp, Tobias
    IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2024, 10 : 1588 - 1601
  • [6] Modeling of two-phase magnetic materials based on Jiles-Atherton theory of hysteresis
    Raghunathan, A.
    Melikhov, Y.
    Snyder, J. E.
    Jiles, D. C.
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2012, 324 (01) : 20 - 22
  • [7] A new hysteresis model based on Weibull cumulative distribution function and Jiles-Atherton hysteresis model
    Xue, Guangming
    Bai, Hongbai
    Li, Tuo
    Ren, Zhiying
    Wu, Zhangbin
    NONLINEAR DYNAMICS, 2024, 112 (8) : 6403 - 6420
  • [8] Dynamic Jiles-Atherton Model for Determining the Magnetic Power Loss at High Frequency in Permanent Magnet Machines
    Du, Ruoyang
    Robertson, Paul
    IEEE TRANSACTIONS ON MAGNETICS, 2015, 51 (06)
  • [9] System Matrix Based Reconstruction for Pulsed Sequences in Magnetic Particle Imaging
    Mohn, Fabian
    Knopp, Tobias
    Boberg, Marija
    Thieben, Florian
    Szwargulski, Patryk
    Graeser, Matthias
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (07) : 1862 - 1873
  • [10] An Easily Used Phenomenological Magnetization Model and Its Empirical Expressions Based on Jiles-Atherton Parameters
    Xue, Guangming
    Bai, Hongbai
    Li, Tuo
    Lu, Chunhong
    MATERIALS, 2022, 15 (21)