Influence of seal clearance of runner on internal fluid field in Francis turbine

被引:0
作者
Wu Z. [1 ]
Liang W. [1 ]
Dong W. [2 ]
Gao C. [1 ]
Chen D. [2 ]
机构
[1] Institute of Water Resources and Hydro-electric Engineering, Xi'an University of Technology, Xi'an
[2] College of Water Resources and Architectural Engineering, Northwest A&F University, Yangling
来源
Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering | 2020年 / 36卷 / 02期
关键词
Francis turbine; Models; Performance; Seal clearance; Volume loss;
D O I
10.11975/j.issn.1002-6819.2020.02.004
中图分类号
学科分类号
摘要
The performance and stability of turbine are easily affected by the complex turbulence such as clearance vortex and leakage flow. For the purpose of analyzing the influence of seal clearance on the energy features and interior flow characteristics of Francis turbine, with referencing N-S equation and SST turbulence model, the three-dimensional steady flow in the full flow passage of the Francis turbine model under five schemes of clearance were calculated. Four flow rates were chosen as: 0.6 Qd, 0.8 Qd, Qd and 1.2 Qd. Five schemes of clearance size were selected of 0.4, 0.6, 0.8, 1.0 and 1.3 mm. By comparing the effects of different clearance schemes on the efficiency and volume loss of Francis turbine, the relationship between clearance and turbine performance was analyzed based on the characteristics of internal fluid field, and the calculation results showed that by increasing the size of clearance, the turbine efficiency could be reduced, and the leakage of the turbine indicated an upward trend. When the turbine operated at a small flow rate of 0.6 Qd, the clearance appeared the most obvious influence on the energy features of the turbine. With the increase of clearance, the leakage ratio increased from 0.18% to 0.54%, and the efficiency decreased by 4.1 percentage points. At the flow rate of 1.2 Qd, the clearance presented the least influence on the energy features of the turbine. The leakage ratio increased from 0.07% to 0.27%, and the efficiency decreased by 1.38 percentage points when the clearance was increased. If the turbine was operated at small flow rates of 0.6 Qd and 0.8 Qd, the clearance increased, and the internal fluid fields inside both the clearance and the draft tube deteriorated slightly. The average velocity in the clearance increased gradually, and the eddy current intensity in the inlet and outlet pressure chambers of the clearance increased little by little, the volume of vortex rope in the center of draft tube inlet was increased simultaneously. If the unit was operated at a large flow rate of 1.2 Qd, with the clearance increased from 0.4 mm to 1.3 mm, the characteristics of fluid field inside clearance and the pressure distribution on the suction surface of the runner blades, also the fluid field inside the draft tube were all improved. The area of negative pressure zone on suction surface of runner blades decreased, and the volume of the cavity vortex rope at the inlet center of the draft tube decreased, the streamline inside the draft tube also tended to be smooth. This study could provide an effective reference for the design of seal clearance of Francis turbine. © 2020, Editorial Department of the Transactions of the Chinese Society of Agricultural Engineering. All right reserved.
引用
收藏
页码:23 / 29
页数:6
相关论文
共 28 条
[21]  
Marsh P., Ranmuthugala D., Penesis I., Et al., The influence of turbulence model and two and three-dimensional domain selection on the simulated performance characteristics of vertical axis tidal turbines, Renewable Energy, 105, pp. 106-116, (2017)
[22]  
Campobasso M.S., Yan M., Bonfiglioli A., Et al., Low-speed preconditioning for strongly coupled integration of Reynolds- averaged Navier-Stokes equations and two-equation turbulence models, Aerospace Science and Technology, 77, 6, pp. 286-298, (2018)
[23]  
Silva P.A.S.F., De Oliveira T.F., Brasil A.C.P., Et al., Numerical study of wake characteristics in a horizontal-axis hydrokinetic turbine, Anais Da Academia Brasileira de Ciencias, 88, 4, pp. 2441-2456, (2016)
[24]  
Chitrakar S., Dahlhaug O.G., Neopane H.P., Numerical Investigation of the Effect of Leakage Flow through Erosion-Induced Clearance Gaps of Guide Vanes on the Performance of Francis turbines, Engineering Applications of Computational Fluid Mechanics, 12, 1, pp. 662-678, (2018)
[25]  
Zhang J., Huang X., Yuan S., Et al., Grid-independence in low specific speed centrifugal pump based on PIV, Journal of Drainage and Irrigation Machinery Engineering, 34, 7, (2016)
[26]  
Min Z., Liang C., Dong Z., Et al., Calculation and analysis of leakage of Francis pump-turbine, Journal of Drainage and Irrigation Machinery Engineering, 32, 8, pp. 41-46, (2014)
[27]  
Guo T., Zhang L., Numerical study of swirling flow fields in Francis turbin eunder small opening condition, Transactions of the Chinese Society for Agricultural Machinery, 45, 9, pp. 117-123, (2014)
[28]  
Zhong L., Lai X., Liao G., Et al., Analysis on the relationship between swirling flow at outlet of a Francis turbine runner and vortex rope inside draft tube, Journal of Hydroelectric Engineering, 37, 9, pp. 42-48, (2018)