EXPERIMENTAL INVESTIGATION ON SEISMIC BEHAVIOR OF T-SHAPED REINFORCED CONCRETE SHEAR WALLS UNDER VARIED BIAXIAL LOADING PATHS

被引:0
|
作者
Wang B. [1 ,2 ]
Wu M.-Z. [2 ]
Shi Q.-X. [1 ,2 ]
Cai W.-Z. [1 ,3 ]
Wang P. [1 ,2 ]
机构
[1] State Key Laboratory of Green Building in Western China, Xi’an University of Architecture & Technology, Shaanxi, Xi’an
[2] School of Civil Engineering, Xi’an University of Architecture & Technology, Shaanxi, Xi’an
[3] School of Urban Planning and Municipal Engineering, Xi’an Polytechnic University, Shaanxi, Xi’an
来源
Gongcheng Lixue/Engineering Mechanics | 2023年 / 40卷 / 07期
关键词
biaxial loading; coupling effect; loading path; quasi-static test; reinforced concrete shear wall; seismic behavior; T-shaped section;
D O I
10.6052/j.issn.1000-4750.2021.11.0928
中图分类号
学科分类号
摘要
To study the damage mechanism and seismic behavior of shear wall with flange under a complex multidimensional earthquake, the uniaxial and biaxial quasi-static tests of five T-shaped reinforced concrete shear walls were carried out. The effect of biaxial loading on the failure mode, on the hysteretic behavior, on the bearing capacity, on the ductility and on the energy dissipation capacity of T-shaped walls were investigated, and the force mechanism and multidimensional seismic behavior of T-shaped walls under different biaxial loading paths were also analyzed. The research results show that the failure part of T-shaped RC walls under both uniaxial and biaxial loadings are concentrated at the bottom of the free end of wall segment. Biaxial loading aggravates the crack development and concrete spalling, and it has a greater impact on flange damage. There is an obvious correlation of the mechanical behavior of T-shaped wall between its two orthogonal directions. The internal force redistribution and local additional stress generated by biaxial loading would change the local stress mechanism and overall performance of T-shaped wall, that is, when the loading in one direction, the force in the orthogonal direction would change under a constant displacement. Compared with uniaxial loading, the bearing capacity under biaxial loading is reduced by 6.90% on average, the ultimate deformation capacity is reduced by 11.28% on average, the cumulative energy consumption in single direction is decreased, and the biaxial coupling effect increases with the loading paths alternating from cruciform to eight-shaped to rectangular. Due to the randomness of ground motion and the multidimensional coupling of structural response will significantly change the seismic capacity of RC wall with flange under a real earthquake, it is suggested to rationaly consider the reduction of bearing capacity and appropriately reduce the inter-story drift ratio limit in the aseismic design of shear wall structures. © 2023 Tsinghua University. All rights reserved.
引用
收藏
页码:145 / 157
页数:12
相关论文
共 25 条
  • [1] WENG Y K, PAMPANIN S., The seismic performance of RC buildings in the 22 February 2011 Christchurch earthquake, Structural Concrete, 12, 4, pp. 223-233, (2011)
  • [2] NAEIM F, LEW M, CARPENTER L D, Et al., Performance of tall buildings in Santiago, Chile during the 27 February 2010 offshore Maule, Chile earthquake [J], Structural Design of Tall & Special Buildings, 20, 1, pp. 1-16, (2011)
  • [3] PARRA T P, MOLHLE J., Recommendations for seismic design of reinforced concrete walls buildings based on studies of the 2010 Chile earthquake, (2014)
  • [4] SUN Chujin, CHENG Qingle, ZENG Xiang, Et al., Comparison of seismic damage and economic loss of campus buildings under different earthquakes, Engineering Mechanics, 36, pp. 111-117, (2019)
  • [5] QIU Fawei, LI Wenfeng, PAN Peng, Et al., Quasi-static test research of reinforced concrete column under biaxial loading, Journal of Building Structures, 22, 5, pp. 26-31, (2001)
  • [6] SHI Qingxuan, WANG Peng, LI Kun, Et al., Influence of loading regimes on seismic behavior of new type steel reinforced concrete columns, Engineering Mechanics, 31, 3, pp. 152-159, (2014)
  • [7] ZHANG Haoyu, QU Bowen, MAO Chenxi, Experimental investigation on seismic performance of reinforced concrete columns under horizontally bi-directional cyclic loading, China Civil Engineering Journal, 52, 8, pp. 49-61, (2019)
  • [8] GU Xianglin, CAI Mao, LIN Feng, Study on behavior of RC columns subjected to earthquake, Engineering Mechanics, 27, 11, pp. 160-165, (2010)
  • [9] AL-ZUHAIRI A H, AL-AHMED A, HANOON A, Et al., Structural behavior of reinforced hybrid concrete columns under biaxial loading [J], Latin American Journal of Solids and Structures, 18, 6, pp. 1-18, (2021)
  • [10] HSU THOMAS C., Biaxially loaded L-shaped reinforced concrete columns, Journal of Structural Engineering, 111, 12, pp. 2576-2595, (1985)