Shortening Acquisition Time and Improving Image Quality for Pelvic MRI Using Deep Learning Reconstruction for Diffusion-Weighted Imaging at 1.5 T

被引:5
作者
Herrmann, Judith [1 ]
Benkert, Thomas [1 ]
Brendlin, Andreas [1 ]
Gassenmaier, Sebastian [1 ]
Hoelldobler, Thomas [1 ]
Maennlin, Simon [1 ]
Almansour, Haidara [1 ]
Lingg, Andreas [1 ]
Weiland, Elisabeth [1 ]
Afat, Saif [1 ]
机构
[1] Eberhard Karls Univ Tuebingen, Dept Diagnost & Intervent Radiol, Hoppe Seyler Str 3, D-72076 Tubingen, Germany
关键词
Diffusion-weighted imaging; Pelvic imaging; MRI; Deep learning reconstruction; SUPERRESOLUTION; BENIGN;
D O I
10.1016/j.acra.2023.06.035
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To determine the impact on acquisition time reduction and image quality of a deep learning (DL) reconstruction for accelerated diffusion-weighted imaging (DWI) of the pelvis at 1.5 T compared to standard DWI. Materials and Methods: A total of 55 patients (mean age, 61 +/- 13 years; range, 27-89; 20 men, 35 women) were consecutively included in this retrospective, monocentric study between February and November 2022. Inclusion criteria were (1) standard DWI (DWIS) in clinically indicated magnetic resonance imaging (MRI) at 1.5 T and (2) DL-reconstructed DWI (DWIDL). All patients were examined using the institution's standard MRI protocol according to their diagnosis including DWI with two different b-values (0 and 800 s/mm(2)) and calculation of apparent diffusion coefficient (ADC) maps. Image quality was qualitatively assessed by four radiologists using a visual 5-point Likert scale (5 = best) for the following criteria: overall image quality, noise level, extent of artifacts, sharpness, and diagnostic confidence. The qualitative scores for DWIS and DWIDL were compared with the Wilcoxon signed-rank test. Results: The overall image quality was evaluated to be significantly superior in DWIDL compared to DWIS for b = 0 s/mm(2), b = 800 s/mm(2), and ADC maps by all readers (P < .05). The extent of noise was evaluated to be significantly less in DWIDL compared to DWIS for b = 0 s/mm(2), b = 800 s/mm(2), and ADC maps by all readers (P < .001). No significant differences were found regarding artifacts, lesion detectability, sharpness of organs, and diagnostic confidence (P > .05). Acquisition time for DWIS was 2:06 minutes, and simulated acquisition time for DWIDL was 1:12 minutes. Conclusion: DL image reconstruction improves image quality, and simulation results suggest that a reduction in acquisition time for diffusion-weighted MRI of the pelvis at 1.5 T is possible.
引用
收藏
页码:921 / 928
页数:8
相关论文
共 50 条
[41]   Deep learning reconstruction of free-breathing, diffusion-weighted imaging of the liver: A comparison with conventional free-breathing acquisition [J].
Yoon, Jiyoung ;
Lee, Yoonhee ;
Yoon, Sungjin ;
Sung, JaeKon ;
Benkert, Thomas ;
Lee, Jungbok ;
Park, So Hyun .
PLOS ONE, 2025, 20 (05)
[42]   Diffusion-Weighted Imaging of the Abdomen at 3.0 Tesla: Image Quality and Apparent Diffusion Coefficient Reproducibility Compared With 1.5 Tesla [J].
Rosenkrantz, Andrew B. ;
Oei, Marcel ;
Babb, James S. ;
Niver, Benjamin E. ;
Taouli, Bachir .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (01) :128-135
[43]   Improving the Quality of Diffusion-weighted Imaging of the Left Hepatic Lobe Using Weighted Averaging of Signals from Multiple Excitations [J].
Ichikawa, Shintaro ;
Motosugi, Utaroh ;
Tamada, Daiki ;
Wakayama, Tetsuya ;
Sato, Kazuyuki ;
Funayama, Satoshi ;
Onishi, Hiroshi .
MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2019, 18 (03) :225-232
[44]   Zoomed echo-planar imaging using parallel transmission: impact on image quality of diffusion-weighted imaging of the prostate at 3T [J].
Andrew B. Rosenkrantz ;
Hersh Chandarana ;
Josef Pfeuffer ;
Michael J. Triolo ;
Mohammed Bilal Shaikh ;
David J. Mossa ;
Christian Geppert .
Abdominal Imaging, 2015, 40 :120-126
[45]   Zoomed echo-planar imaging using parallel transmission: impact on image quality of diffusion-weighted imaging of the prostate at 3T [J].
Rosenkrantz, Andrew B. ;
Chandarana, Hersh ;
Pfeuffer, Josef ;
Triolo, Michael J. ;
Shaikh, Mohammed Bilal ;
Mossa, David J. ;
Geppert, Christian .
ABDOMINAL IMAGING, 2015, 40 (01) :120-126
[46]   Deep learning-accelerated T2-weighted imaging versus conventional T2-weighted imaging in the female pelvic cavity: image quality and diagnostic performance [J].
Kim, Hokun ;
Choi, Moon Hyung ;
Lee, Young Joon ;
Han, Dongyeob ;
Mostapha, Mahmoud ;
Nickel, Dominik .
ACTA RADIOLOGICA, 2024, 65 (05) :499-505
[47]   Evaluation of locally recurrent pelvic malignancy: Performance of T2- and diffusion-weighted MRI with image fusion [J].
Nishie, Akihiro ;
Stolpen, Alan H. ;
Obuchi, Masao ;
Kuehn, David M. ;
Dagit, Aaron ;
Andresen, Kelli .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (03) :705-713
[48]   Speeding Up and Improving Image Quality in Glioblastoma MRI Protocol by Deep Learning Image Reconstruction [J].
Gohla, Georg ;
Hauser, Till-Karsten ;
Bombach, Paula ;
Feucht, Daniel ;
Estler, Arne ;
Bornemann, Antje ;
Zerweck, Leonie ;
Weinbrenner, Eliane ;
Ernemann, Ulrike ;
Ruff, Christer .
CANCERS, 2024, 16 (10)
[49]   The applied research of simultaneous image acquisition of T2-weighted imaging (T2WI) and diffusion-weighted imaging (DWI) in the assessment of patients with prostate cancer [J].
Liu, Yi ;
Wang, Wei ;
Qin, Xiu-Bo ;
Wang, Hui-Hui ;
Gao, Ge ;
Zhang, Xiao-Dong ;
Wang, Xiao-Ying .
ASIAN JOURNAL OF ANDROLOGY, 2019, 21 (02) :177-182
[50]   Compressed sensing and deep learning reconstruction for women's pelvic MRI denoising: Utility for improving image quality and examination time in routine clinical practice [J].
Ueda, Takahiro ;
Ohno, Yoshiharu ;
Yamamoto, Kaori ;
Iwase, Akiyoshi ;
Fukuba, Takashi ;
Hanamatsu, Satomu ;
Obama, Yuki ;
Ikeda, Hirotaka ;
Ikedo, Masato ;
Yui, Masao ;
Murayama, Kazuhiro ;
Toyama, Hiroshi .
EUROPEAN JOURNAL OF RADIOLOGY, 2021, 134