Intraoperative live measurement of femoral head size for acetabular cup sizing: simple, accurate, and green!

被引:1
作者
Assi, Chahine [1 ,2 ]
Boulos, Karl [1 ,2 ]
Haykal, Emil [1 ]
Caton, Jacques [3 ]
Prudhon, Jean Louis [4 ]
Yammine, Kaissar [1 ,2 ]
机构
[1] Lebanese Amer Univ, Sch Med, Rizk Hosp, Dept Orthoped Surg,Med Ctr, Beirut, Lebanon
[2] Ctr Evidence Based Anat, Sport & Orthoped Res, Beirut, Lebanon
[3] Inst Chirurg Orthoped, Lyon, France
[4] Chirurg Orthoped, Clin Cedres, Echirolles, France
关键词
Total hip arthroplasty; Dual mobility cup; Templating; Measurement; Femoral head size; DIGITAL RADIOGRAPHS;
D O I
10.1007/s00264-024-06211-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Templating is the first step in achieving a successful total hip arthroplasty. We hypothesize that native head size is highly correlated with implanted cup size. Therefore, the purpose of this study is to look for a correlation between sizes of the intra-operative measurement of the femoral head and the implanted cup. Methods This is a monocentric observational study conducted from December 2018 till January 2023. All patients admitted for a primary total hip arthroplasty were included and retrospectively reviewed. Intra-operative femoral head measurement, radiographic femoral head diameter, templated (planned) cup size, and definitive implanted cup size were recorded. Results The sample included 154 patients (85 female and 69 males) with a mean age of 66.2 +/- 10.4 years. There were 157 THA cases; 82 on the right side and 75 on the left side. The native head size and acetate template on digital radiographs were the most significantly positively correlated with cup size (P < 0.0001) while the radiological head size was significantly negatively correlated with cup size (P = 0.009). The implanted cup was on average 2 +/- 2 mm bigger than the native head size measured intra-operatively. Conclusion The native femoral head diameter measured intra-operatively is a simple and reliable tool to help the surgeons choose the proper size of the acetabular cup, preventing complications during surgery hence optimizing results post operatively. This technique would contribute to a more ecofriendly orthopaedic reconstructive surgery.
引用
收藏
页码:2025 / 2031
页数:7
相关论文
共 21 条
[1]   Reducing the environmental impact of surgery on a global scale: systematic review and co-prioritization with healthcare workers in 132 countries [J].
Adisa, Adewale ;
Bahrami-Hessari, Michael ;
Bhangu, Aneel ;
George, Christina ;
Ghosh, Dhruv ;
Glasbey, James ;
Haque, Parvez ;
Ingabire, J. C. Allen ;
Kamarajah, Sivesh Kathir ;
Kudrna, Laura ;
Ledda, Virginia ;
Li, Elizabeth ;
Lillywhite, Robert ;
Mittal, Rohin ;
Nepogodiev, Dmitri ;
Ntirenganya, Faustin ;
Picciochi, Maria ;
Filipa, Joana ;
Simoes, Ferreira ;
Bahrami-Hessari, M. ;
Bhangu, A. ;
Booth, L. ;
Elliot, R. ;
Glasbey, J. ;
Kennerton, A. S. ;
Pettigrove, K. L. ;
Pinney, L. ;
Richard, H. ;
Tottman, R. ;
Wheatstone, P. ;
Wolfenden, John W. D. ;
Simoes, J. ;
Smith, A. ;
Sayed, A. Emad ;
Goswami, Aakansha Giri ;
Malik, Aamer ;
Mclean, Aaron Lawson ;
Hassan, Abbas ;
Nazimi, Abd Jabar ;
Aladna, Abdallah ;
Abdelgawad, Abdalrahman ;
Saed, Abdel ;
Abdelmageed, Abdelfatah ;
Ghannam, Abdelilah ;
Mahmoud, Abdelrahman ;
Alvi, Abdul ;
Ismail, Abdulaziz ;
Adesunkanmi, Abdulhafiz ;
Ebrahim, Abdulla ;
Al-Mallah, Abdullah .
BJS-BRITISH JOURNAL OF SURGERY, 2023, 110 (07) :804-817
[2]   The 3-dot circle: A reliable method for safe and efficient digital templating of the acetabular component [J].
Arnaout, Firas ;
Dewan, Varun ;
Paliobeis, Christos .
JOURNAL OF ORTHOPAEDICS, 2018, 15 (03) :787-791
[3]   Measuring the Femoral Head Size - An Additional Real-Time Intraoperative Monitoring Tool for the Accuracy of the Preoperative Process and Implant Selection [J].
Ben Iulu, Oren ;
Rubin, Guy ;
Krasnyansky, Semion ;
Elbaz, Avi ;
Segal, Ganit ;
Rozen, Nimrod .
JOURNAL OF ARTHROPLASTY, 2015, 30 (12) :2201-2203
[4]   An AOA critical issue the outcome of the outcomes movement [J].
Bourne, RB ;
Maloney, WJ ;
Wright, JG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (03) :633-640
[5]   Scaling Digital Radiographs for Templating in Total Hip Arthroplasty Using Conventional Acetate Templates Independent of Calibration Markers [J].
Brew, Christopher J. ;
Simpson, Philip M. ;
Whitehouse, Sarah L. ;
Donnelly, William ;
Crawford, Ross W. ;
Hubble, Matthew J. W. .
JOURNAL OF ARTHROPLASTY, 2012, 27 (04) :643-647
[6]   DETERMINATION OF ACCURACY OF PREOPERATIVE TEMPLATING OF NONCEMENTED FEMORAL PROSTHESES [J].
CARTER, LW ;
STOVALL, DO ;
YOUNG, TR .
JOURNAL OF ARTHROPLASTY, 1995, 10 (04) :507-513
[7]   Preoperative sizing of hip hemiarthroplasties to accurately estimate head size from non-standardised pelvic radiographs: Can it be done? [J].
Crosswell, Sebastien ;
Akehurst, Harold ;
Ramiah, Reagon ;
Navadgi, Basalingappa .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (11) :2030-2033
[8]   Preoperative planning for primary total hip arthroplasty [J].
Della Valle, AG ;
Padgett, DE ;
Salvati, EA .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2005, 13 (07) :455-462
[9]   Artificial intelligence-based three-dimensional templating for total joint arthroplasty planning: a scoping review [J].
Garcia, Ausberto Velasquez ;
Bukowiec, Lainey G. ;
Yang, Linjun ;
Nishikawa, Hiroki ;
Fitzsimmons, James S. ;
Larson, A. Noelle ;
Taunton, Michael J. ;
Sanchez-Sotelo, Joaquin ;
O'Driscoll, Shawn W. ;
Wyles, Cody C. .
INTERNATIONAL ORTHOPAEDICS, 2024, 48 (04) :997-1010
[10]   The utility and precision of analogue and digital preoperative planning for total hip arthroplasty [J].
Gonzalez Della Valle, Alejandro ;
Comba, Fernando ;
Taveras, Nicole ;
Salvati, Eduardo A. .
INTERNATIONAL ORTHOPAEDICS, 2008, 32 (03) :289-294