The Development of a Thick-Lens Post-Myopic Laser Vision Correction Intraocular Lens Calculation Formula

被引:5
作者
Debellemaniere, Guillaume [1 ]
Mechleb, Nicole [1 ]
Bernier, Timothte [2 ]
Ancel, Jean-marc [2 ]
Gauvin, Mathieu [3 ,4 ]
Wallerstein, Avi [3 ,4 ]
Saad, Alain [1 ]
Gatinel, Damien [1 ,5 ]
机构
[1] Rothschild Fdn Hosp, Dept Ophthalmol, Paris, France
[2] Clin Ophtalmol Lamartine, Paris, France
[3] McGill Univ, Dept Ophthalmol & Visual Sci, Montreal, PQ, Canada
[4] LASIK MD, Montreal, PQ, Canada
[5] Hop Fdn Adolphe Rothschild, Paris, France
关键词
CORNEAL POWER MEASUREMENTS; TRUE-K FORMULA; REFRACTIVE SURGERY; CATARACT-SURGERY; EYES; PREDICTION; ABLATION; ACCURACY;
D O I
10.1016/j.ajo.2023.09.023
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: To describe the development of the postmyopic laser vision correction (LVC) version of the PEARL-DGS intraocular lens (IOL) calculation formula and to evaluate its outcomes on an independent test set. center dot DESIGN: Retrospective, single -center case series. center dot METHODS: A modified lens position prediction algorithm was designed along with methods to predict the posterior corneal curvature radius and correct the corneal power measurement error. A different set of previously operated eyes that underwent LVC was used to evaluate the prediction precision of the post-LVC formula. center dot RESULTS: Post-LVC PEARL-DGS formula significantly reduced mean absolute error of prediction in comparison to Haigis-L, Shammas, and American Society of Cataract and Refractive Surgery (ASCRS) average formulas ( P < .001). It exhibited similar postoperative refractive precision as the Barrett True -K No History formula ( P = .61). center dot CONCLUSION: The post-LVC formula development process described in this article performed as well as the state -of -the -art post-LVC formula on the present test set. Further studies are required to assess its efficacy in other independent sets. (Am J Ophthalmol 2024;262: 4047. (c) 2023 The Authors. Published by Elsevier Inc. This is an open access article under the CC BY license ( http://creativecommons.org/licenses/by/4.0/ ))
引用
收藏
页码:40 / 47
页数:8
相关论文
共 27 条
[1]   Accuracy of the Barrett True-K formula for intraocular lens power prediction after laser in situ keratomileusis or photorefractive keratectomy for myopia [J].
Abulafia, Adi ;
Hill, Warren E. ;
Koch, Douglas D. ;
Wang, Li ;
Barrett, Graham D. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (03) :363-369
[2]   Intraocular lens power calculation in eyes with previous corneal refractive surgery [J].
Anders, Philipp ;
Anders, Lisa-Marie ;
Barbara, Adel ;
Szentmary, Nora ;
Langenbucher, Achim ;
Gatzioufas, Zisis .
THERAPEUTIC ADVANCES IN OPHTHALMOLOGY, 2022, 14
[3]   Intraocular lens power calculation after corneal refractive surgery: Double-K method [J].
Aramberri, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (11) :2063-2068
[4]   Corneal tissue ablation depth and the Munnerlyn formula [J].
Chang, AW ;
Tsang, AC ;
Contreras, JE ;
Huynh, PD ;
Calvano, CJ ;
Crnic-Rein, TC ;
Thall, EH .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (06) :1204-1210
[5]   Assessment of the accuracy of new and updated intraocular lens power calculation formulas in 10 930 eyes from the UK National Health Service [J].
Darcy, Kieren ;
Gunn, David ;
Tavassoli, Shokufeh ;
Sparrow, John ;
Kane, Jack X. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (01) :2-7
[6]   The PEARL-DGS Formula: The Development of an Open-source Machine Learning-based Thick IOL Calculation Formula [J].
Debellemaniere, Guillaume ;
Dubois, Mathieu ;
Gauvin, Mathieu ;
Wallerstein, Avi ;
Brenner, Luis F. ;
Rampat, Radhika ;
Saad, Alain ;
Gatinel, Damien .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2021, 232 :58-69
[7]   Refractive Accuracy of Barrett True-K vs Intraoperative Aberrometry for IOL Power Calculation in Post-Corneal Refractive Surgery Eyes [J].
Gouvea, Larissa ;
Sioufi, Kareem ;
Brown, Colin E. ;
Waring, George ;
Chamon, Wallace ;
Rocha, Karolinne Maia .
CLINICAL OPHTHALMOLOGY, 2021, 15 :4305-4315
[8]   Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula [J].
Haigis, Wolfgang .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (10) :1658-1663
[9]   Review and recommendations for univariate statistical analysis of spherical equivalent prediction error for IOL power calculations [J].
Holladay, Jack T. ;
Wilcox, Rand R. ;
Koch, Douglas D. ;
Wang, Li .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (01) :65-77
[10]  
IOL Con, About us