A graphene oxide-modified biosensor for non-invasive glucose monitoring in college athletes

被引:1
|
作者
Chen, Li [1 ]
Zhang, Yong [2 ]
Hu, Tongyi [3 ]
机构
[1] Chongqing Normal Univ, Coll Phys Educ & Hlth Sci, Chongqing 401331, Peoples R China
[2] Sichuan Int Studies Univ, Chongqing 400031, Peoples R China
[3] Chongqing Med & Pharmaceut Coll, Fdn Dept, Chongqing 401331, Peoples R China
关键词
PdO nanoparticles; Reduced Graphene Oxide; Glucose monitoring; Athletes; Differential Pulse Voltammetry; BLOOD-GLUCOSE; PALLADIUM NANOPARTICLES; ELECTROCHEMICAL GLUCOSE; PERFORMANCE; POLYMER; SENSOR; ACID;
D O I
10.1016/j.aej.2024.03.051
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The study aims to address the need for accurate and real -time monitoring of glucose levels in college athletes during physical activities. This work reports on the development of an electrochemical sensor that uses glucose oxidase (GOx) immobilized on PdO nanoparticles to reduce graphene oxide (rGO) nanocomposite printed on a cellulose substrate (GO x /PdO-rGO/C-PE). The successful reduction of GO to rGO, the production of the PdO-rGO nanocomposite, and the electropolymerization of GOx on the PdO-rGO nanocomposite were all validated by the material characterization. The biosensor ' s electrochemical response investigation showed that its detection limit was 0.046 mu M and its sensitivity was 0.03239 mu A/ mu M. Excellent stability, reproducibility, and glucose selectivity were shown by the GOx/PdO-rGO/C-PE, which makes it a viable option for consistent and dependable glucose sensing in real-world applications. The real sample analysis assessed how well the combination of GOx/PdOrGO/C-PE could identify glucose in human serum. Furthermore, under a variety of real-world conditions, such as during various physical activities and at different times of the day, the sensor demonstrated outstanding performance in real -time glucose monitoring. These findings imply that the GOx/PdO-rGO/C-PE offers accurate and dependable readings in the field of non-invasive glucose monitoring, which will be especially helpful for college and professional athletes.
引用
收藏
页码:321 / 332
页数:12
相关论文
共 50 条
  • [41] Electrodeposition of copper oxide/polypyrrole/reduced graphene oxide as a nonenzymatic glucose biosensor
    Nia, Pooria Moozarm
    Meng, Woi Pei
    Lorestani, Farnaz
    Mahmoudian, M. R.
    Alias, Y.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 209 : 100 - 108
  • [42] A Novel Miniature Spiral Sensor for Non-invasive Blood Glucose Monitoring
    Shao, Jinjin
    Yang, Fan
    Xia, Fen
    Zhang, Qingfeng
    Chen, Yifan
    2016 10TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2016,
  • [43] Study on Graphene Oxide-Modified Polyacrylonitrile Hollow Fiber Membrane
    Yang, Shu-Jing
    Han, Xue-Xue
    Zhang, Xin-Feng
    Wang, Song
    Cong, Hai-Lin
    Wang, Xue-Jie
    Li, Long-Bin
    Cui, Xi-Chao
    Wang, Hang-Qi
    Shen, You-Qing
    Yu, Bing
    INTEGRATED FERROELECTRICS, 2020, 207 (01) : 62 - 74
  • [44] A Label-free Electrochemical Biosensor for Acrylamide Based on DNA Immobilized on Graphene Oxide-Modified Glassy Carbon Electrode
    Li, Dan
    Xu, Yunmei
    Zhang, Ling
    Tong, Haixia
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (12): : 7217 - 7227
  • [45] Non-invasive microwave blood glucose monitoring based on the diffusion limited aggregation earlobe model
    Yang, Chenxi
    Xiao, Xia
    Hu, Min
    Wang, Zengxiang
    INTERNATIONAL JOURNAL OF RF AND MICROWAVE COMPUTER-AIDED ENGINEERING, 2022, 32 (12)
  • [46] Recent Progress and Perspectives on Non-Invasive Glucose Sensors
    Davison, Nicholas B.
    Gaffney, Christopher J.
    Kerns, Jemma G.
    Zhuang, Qiandong D.
    DIABETOLOGY, 2022, 3 (01): : 56 - 71
  • [47] Electrochemical H2O2 biosensor based on horseradish peroxidase encapsulated protein nanoparticles with reduced graphene oxide-modified gold electrode
    Shin, Jeong-Hyeop
    Lee, Myeong-Jun
    Choi, Jin-Ha
    Song, Ji-ae
    Kim, Tae-Hwan
    Oh, Byung-Keun
    NANO CONVERGENCE, 2020, 7 (01)
  • [48] Non-invasive continuous glucose monitoring in Type I diabetic patients with optical glucose sensors
    L. Heinemann
    G. Schmelzeisen-Redeker
    Diabetologia, 1998, 41 : 848 - 854
  • [49] Non-Invasive Real-Time Monitoring of Glucose Level Using Novel Microwave Biosensor Based on Triple-Pole CSRR
    Omer, Ala Eldin
    Shaker, George
    Safavi-Naeini, Safieddin
    Alquie, Georges
    Deshours, Frederique
    Kokabi, Hamid
    Shubair, Raed M.
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2020, 14 (06) : 1407 - 1420
  • [50] Graphene Oxide-Modified Polyacrylonitrile Nanofibrous Membranes for Efficient Air Filtration
    Zhang, Chaoran
    Yao, Lu
    Yang, Zhi
    Kong, Eric Siu-Wai
    Zhu, Xiaofeng
    Zhang, Yafei
    ACS APPLIED NANO MATERIALS, 2019, 2 (06): : 3916 - 3924