A graphene oxide-modified biosensor for non-invasive glucose monitoring in college athletes

被引:1
|
作者
Chen, Li [1 ]
Zhang, Yong [2 ]
Hu, Tongyi [3 ]
机构
[1] Chongqing Normal Univ, Coll Phys Educ & Hlth Sci, Chongqing 401331, Peoples R China
[2] Sichuan Int Studies Univ, Chongqing 400031, Peoples R China
[3] Chongqing Med & Pharmaceut Coll, Fdn Dept, Chongqing 401331, Peoples R China
关键词
PdO nanoparticles; Reduced Graphene Oxide; Glucose monitoring; Athletes; Differential Pulse Voltammetry; BLOOD-GLUCOSE; PALLADIUM NANOPARTICLES; ELECTROCHEMICAL GLUCOSE; PERFORMANCE; POLYMER; SENSOR; ACID;
D O I
10.1016/j.aej.2024.03.051
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The study aims to address the need for accurate and real -time monitoring of glucose levels in college athletes during physical activities. This work reports on the development of an electrochemical sensor that uses glucose oxidase (GOx) immobilized on PdO nanoparticles to reduce graphene oxide (rGO) nanocomposite printed on a cellulose substrate (GO x /PdO-rGO/C-PE). The successful reduction of GO to rGO, the production of the PdO-rGO nanocomposite, and the electropolymerization of GOx on the PdO-rGO nanocomposite were all validated by the material characterization. The biosensor ' s electrochemical response investigation showed that its detection limit was 0.046 mu M and its sensitivity was 0.03239 mu A/ mu M. Excellent stability, reproducibility, and glucose selectivity were shown by the GOx/PdO-rGO/C-PE, which makes it a viable option for consistent and dependable glucose sensing in real-world applications. The real sample analysis assessed how well the combination of GOx/PdOrGO/C-PE could identify glucose in human serum. Furthermore, under a variety of real-world conditions, such as during various physical activities and at different times of the day, the sensor demonstrated outstanding performance in real -time glucose monitoring. These findings imply that the GOx/PdO-rGO/C-PE offers accurate and dependable readings in the field of non-invasive glucose monitoring, which will be especially helpful for college and professional athletes.
引用
收藏
页码:321 / 332
页数:12
相关论文
共 50 条
  • [21] Graphene oxide-modified electrodes for sensitive determination of diethylstilbestrol
    Yu, Chunmei
    Ji, Wanyu
    Wang, Yidan
    Bao, Ning
    Gu, Haiying
    NANOTECHNOLOGY, 2013, 24 (11)
  • [22] Recent developments in non-invasive blood glucose monitoring technology
    LIU Rong
    MENG Danrui
    XU Kexin
    Instrumentation, 2016, 3 (04) : 3 - 14
  • [23] Glucose biosensor using fluorescence quenching with chitosan-modified graphene oxide
    Li, Wenjun
    Jiang, Tingting
    Pu, Yang
    Jiao, Xudong
    Tan, Wenqiang
    Qin, Song
    MICRO & NANO LETTERS, 2019, 14 (03) : 344 - 348
  • [24] A novel electrochemiluminescence glucose biosensor based on platinum nanoflowers/graphene oxide/glucose oxidase modified glassy carbon electrode
    Tian, Xiaotian
    Lian, Sai
    Zhao, Limin
    Chen, Xiaomei
    Huang, Zhiyong
    Chen, Xi
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2014, 18 (09) : 2375 - 2382
  • [25] Carbon nanotubes/polyethylenimine/glucose oxidase as a non-invasive electrochemical biosensor performs high sensitivity for detecting glucose in saliva
    Tai, Nyan-Hwa
    Lin, Meng-Hsien
    Gupta, Shivam
    Chang, Ching
    Lee, Chi-Young
    MICROCHEMICAL JOURNAL, 2022, 180
  • [26] Wearable-band type visible-near infrared optical biosensor for non-invasive blood glucose monitoring
    Rachim, Vega Pradana
    Chung, Wan-Young
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 286 : 173 - 180
  • [27] A comprehensive review on electromagnetic wave based non-invasive glucose monitoring in microwave frequencies
    Kandwal, Abhishek
    Sharma, Yogeshwar Dutt
    Jasrotia, Rohit
    Kit, Chan Choon
    Lakshmaiya, Natrayan
    Sillanpaa, Mika
    Liu, Louis W. Y.
    Igbe, Tobore
    Kumari, Asha
    Sharma, Rahul
    Kumar, Suresh
    Sungoum, Chongkol
    HELIYON, 2024, 10 (18)
  • [28] On Non-Invasive Glucose Measurements
    Aroutiounian, V. M.
    JOURNAL OF CONTEMPORARY PHYSICS-ARMENIAN ACADEMY OF SCIENCES, 2022, 57 (04) : 405 - 416
  • [29] Non-invasive and wearable glucose biosensor based on gel electrolyte for detection of human sweat
    Gao, Nan
    Cai, Zhiwei
    Chang, Gang
    He, Yunbin
    JOURNAL OF MATERIALS SCIENCE, 2023, 58 (02) : 890 - 901
  • [30] A Glucose Sensing Contact Lens: A Non-Invasive Technique for Continuous Physiological Glucose Monitoring
    Ramachandram Badugu
    Joseph R. Lakowicz
    Chris D. Geddes
    Journal of Fluorescence, 2003, 13 : 371 - 374