Dynamic versus standard bougies for tracheal intubation with direct or indirect laryngoscopy in simulated or real scenarios: a systematic review and meta-analysis

被引:1
作者
Sastre, Jose A. [1 ]
Gomez-Rios, Manuel A. [2 ]
Lopez, Teresa [1 ]
Gutierrez-Couto, Uxia [3 ]
Casans-Frances, Ruben [4 ]
机构
[1] Salamanca Univ Hosp, Dept Anesthesiol, Paseo Transic S-N, Salamanca 37007, Spain
[2] Complejo Hosp Univ Coruna, Dept Anesthesiol & Perioperat Med, La Coruna, Spain
[3] Complejo Hosp Univ Ferrol, Dept Librarry Sci & Documentat, Ferrol, Spain
[4] Hosp Univ Infanta Elena, Dept Anesthesiol, Madrid, Spain
关键词
Airway management; difficult airway; tracheal intubation; bougie; stylet; laryngoscopy; OROTRACHEAL INTUBATION; AIRWAY MANAGEMENT; DIFFICULT AIRWAY; STYLET; MANNEQUIN; SUCCESS;
D O I
10.1080/17434440.2024.2344667
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
IntroductionThis systematic review and meta-analysis aimed to compare the efficacy of dynamic versus standard bougies to achieve tracheal intubation. MethodsWe searched MEDLINE, Embase, CENTRAL, Web of Science, Scopus and Google Scholar on 10 October 2023. We included clinical trials comparing both devices. The primary outcome was the first-attempt intubation success rate. The secondary outcome was the time required for tracheal intubation. ResultsEighteen studies were included. Dynamic bougies do not increase first-attempt success rate (RR 1.11; p = 0.06) or shorten tracheal intubation time (MD -0.30 sec; p = 0.84) in clinical trials in humans. In difficult airways, first-attempt success intubation rate was greater for dynamic bougies (RR 1.17; p = 0.002); Additionally, they reduced the time required for intubation (MD -4.80 sec; p = 0.001). First-attempt intubation success rate was higher (RR 1.15; p = 0.01) and time to achieve intubation was shorter when using Macintosh blades combined with dynamic bougies (MD -5.38 sec; p < 0.00001). Heterogeneity was high. ConclusionDynamic bougies do not increase the overall first-pass success rate or shorten tracheal intubation time. However, dynamic bougies seem to improve first-attempt tracheal intubation rate in patients with difficult airways and in those intubated with a Macintosh blade. Further research is needed for definitive conclusions. Registration of PROSPEROCRD42023472122
引用
收藏
页码:427 / 438
页数:12
相关论文
共 37 条
[1]  
Al-Qasmi Aida, 2015, Anesth Pain Med, V5, pe32299, DOI 10.5812/aapm.32299
[2]   Emergency airway management in Australian and New Zealand emergency departments: A multicentre descriptive study of 3710 emergency intubations [J].
Alkhouri, Hatem ;
Vassiliadis, John ;
Murray, Matthew ;
Mackenzie, John ;
Tzannes, Alex ;
McCarthy, Sally ;
Fogg, Toby .
EMERGENCY MEDICINE AUSTRALASIA, 2017, 29 (05) :499-508
[3]   Success of Intubation Rescue Techniques after Failed Direct Laryngoscopy in Adults A Retrospective Comparative Analysis from the Multicenter Perioperative Outcomes Group [J].
Aziz, Michael F. ;
Brambrink, Ansgar M. ;
Healy, David W. ;
Willett, Amy Wen ;
Shanks, Amy ;
Tremper, Tyler ;
Jameson, Leslie ;
Ragheb, Jacqueline ;
Biggs, Daniel A. ;
Paganelli, William C. ;
Rao, Janavi ;
Epps, Jerry L. ;
Colquhoun, Douglas A. ;
Bakke, Patrick ;
Kheterpal, Sachin .
ANESTHESIOLOGY, 2016, 125 (04) :656-666
[4]   Flexible tip bougie-the new introducer for intubation during cardiopulmonary resuscitation A randomized crossover manikin study [J].
Baczek, Michal ;
Zaganczyk-Baczek, Michalina .
MEDICINE, 2020, 99 (01)
[5]   Comparison between GlideRite® rigid stylet and Parker Flex-It™ stylet to facilitate GlideScope intubation in simulated difficult intubation: a randomized controlled study [J].
Bak, Ji Won ;
Noh, Yeonji ;
Kim, Juyoun ;
Hwang, Byeongmun ;
Kang, Seongsik ;
Son, Heejeong ;
Kim, Minsoo .
ANESTHESIA AND PAIN MEDICINE, 2022, 17 (01) :104-111
[6]   Evaluation of the D-FLECT® deflectable-tip bougie in a manikin with a simulated difficult airway [J].
Booth, A. W. G. ;
Wyssusek, K. H. ;
Lee, P. K. ;
Pelecanos, A. M. ;
Sturgess, D. ;
van Zundert, A. A. J. .
BRITISH JOURNAL OF ANAESTHESIA, 2018, 121 (05) :1180-1182
[7]   A randomised crossover comparison of two endotracheal tube introducers: the FROVA and the Flexible Tip Bougie for GlideScope intubation of a difficult airway manikin by infrequent intubators [J].
Cormack, John ;
Langley, Bridget ;
Bhanabhai, Louisa-Rose ;
Kluger, Roman .
INTERNATIONAL JOURNAL OF EMERGENCY MEDICINE, 2020, 13 (01)
[8]   Effect of Use of a Bougie vs Endotracheal Tube With Stylet on Successful Intubation on the First Attempt Among Critically Ill Patients Undergoing Tracheal Intubation A Randomized Clinical Trial [J].
Driver, Brian E. ;
Semler, Matthew W. ;
Self, Wesley H. ;
Ginde, Adit A. ;
Trent, Stacy A. ;
Gandotra, Sheetal ;
Smith, Lane M. ;
Page, David B. ;
Vonderhaar, Derek J. ;
West, Jason R. ;
Joffe, Aaron M. ;
Mitchell, Steven H. ;
Doerschug, Kevin C. ;
Hughes, Christopher G. ;
High, Kevin ;
Landsperger, Janna S. ;
Jackson, Karen E. ;
Howell, Michelle P. ;
Robison, Sarah W. ;
Gaillard, John P. ;
Whitson, Micah R. ;
Barnes, Christopher M. ;
Latimer, Andrew J. ;
Koppurapu, Vikas S. ;
Alvis, Bret D. ;
Russell, Derek W. ;
Gibbs, Kevin W. ;
Wang, Li ;
Lindsell, Christopher J. ;
Janz, David R. ;
Rice, Todd W. ;
Prekker, Matthew E. ;
Casey, Jonathan D. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2021, 326 (24) :2488-2497
[9]   Effect of Use of a Bougie vs Endotracheal Tube and Stylet on First-Attempt Intubation Success Among Patients With Difficult Airways Undergoing Emergency Intubation A Randomized Clinical Trial [J].
Driver, Brian E. ;
Prekker, Matthew E. ;
Klein, Lauren R. ;
Reardon, Robert F. ;
Miner, James R. ;
Fagerstrom, Erik T. ;
Cleghorn, Mitchell R. ;
McGill, John W. ;
Cole, Jon B. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2018, 319 (21) :2179-2189
[10]  
Frass M., 2019, Disaster Emerg. Med. J, V4, P50, DOI [10.5603/DEMJ.2019.0010, DOI 10.5603/DEMJ.2019.0010]