The three-dimensional stability and accuracy of 3D printing surgical templates: An In Vitro study

被引:10
作者
Lan, Dongping [1 ,2 ,3 ,4 ]
Luo, Yilin [1 ,2 ,3 ,4 ]
Qu, Yili [1 ,3 ,4 ,5 ]
Man, Yi [1 ,2 ,3 ,4 ,6 ]
机构
[1] Sichuan Univ, West China Hosp Stomatol, State Key Lab Oral Dis, Chengdu 610041, Sichuan, Peoples R China
[2] Sichuan Univ, West China Hosp Stomatol, Natl Ctr Stomatol, Chengdu 610041, Sichuan, Peoples R China
[3] Sichuan Univ, West China Hosp Stomatol, Natl Clin Res Ctr Oral Dis, Chengdu 610041, Sichuan, Peoples R China
[4] Sichuan Univ, West China Hosp Stomatol, Dept Oral Implantol, Chengdu 610041, Sichuan, Peoples R China
[5] Sichuan Univ, West China Hosp Stomatol, Dept Prosthodont, Chengdu 610041, Sichuan, Peoples R China
[6] 3rd Sect,Renmin Nan Rd, Chengdu 610041, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
Guided surgery; Surgical template; 3D printing; accuracy; AIDED IMPLANT-SURGERY; DISADVANTAGES; ADVANTAGES; PLACEMENT; ALLOYS;
D O I
10.1016/j.jdent.2024.104936
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To evaluate the three-dimensional (3D) stability and accuracy of additively manufactured surgical templates fabricated using two different 3D printers and materials. Materials and Methods: Forty surgical templates were designed and printed using two different 3D printers: the resin group ( n = 20) used a digital light processing (DLP) 3D printer with photopolymer resin, and the metal group ( n = 20) employed a selective laser melting (SLM) 3D printer with titanium alloy. All surgical templates were scanned immediately after production and re -digitalized after one month of storage. Similarly, the implant simulations were performed twice. Three-dimensional congruency between the original design and the manufactured surgical templates was quantified using the root mean square (RMS), and the definitive and planned implant positions were determined and compared. Results: At the postproduction stage, the metal templates exhibited higher accuracy than the resin templates ( p < 0.001), and these differences persisted after one month of storage ( p < 0.001). The resin templates demonstrated a significant decrease in three-dimensional stability after one month of storage ( p < 0.001), whereas the metal templates were not affected ( p > 0.05). No significant differences in implant accuracy were found between the two groups. However, the resin templates showed a significant increase in apical and angular deviations after one month of storage ( p < 0.001), whereas the metal templates were not affected ( p > 0.05). Conclusion: Printed metal templates showed higher fabrication accuracy than printed resin templates. The threedimensional stability and implant accuracy of printed metal templates remained unaffected by one month of storage. Clinical significance: With superior three-dimensional stability and acceptable implant accuracy, printed metal templates can be considered a viable alternative technique for guided surgery.
引用
收藏
页数:8
相关论文
共 42 条
[1]   Removable partial denture alloys processed by laser-sintering technique [J].
Alageel, Omar ;
Abdallah, Mohamed-Nur ;
Alsheghri, Ammar ;
Song, Jun ;
Caron, Eric ;
Tamimi, Faleh .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2018, 106 (03) :1174-1185
[2]   Factors Influencing the Dimensional Accuracy of 3D-Printed Full-Coverage Dental Restorations Using Stereolithography Technology [J].
Alharbi, Nawal ;
Osman, Reham B. ;
Wismeijer, Daniel .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2016, 29 (05) :503-510
[3]   Stability of Contour Augmentation and Esthetic Outcomes of Implant-Supported Single Crowns in the Esthetic Zone: 3-Year Results of a Prospective Study With Early Implant Placement Postextraction [J].
Buser, Daniel ;
Wittneben, Julia ;
Bornstein, Michael M. ;
Gruetter, Linda ;
Chappuis, Vivianne ;
Belser, Urs C. .
JOURNAL OF PERIODONTOLOGY, 2011, 82 (03) :342-349
[4]   CAD-CAM titanium preparation template for the socket-shield technique [J].
Chen, Li ;
Yang, Zhen ;
Liu, Xiaoqiang ;
Lin, Wei-Shao ;
Tan, Jianguo .
JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (06) :786-790
[5]   Accuracy, reproducibility, and dimensional stability of additively manufactured surgical templates [J].
Chen, Li ;
Lin, Wei-Shao ;
Polido, Waldemar D. ;
Eckert, George J. ;
Morton, Dean .
JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (03) :309-314
[6]   Influence of implant macrodesign and insertion connection technology on the accuracy of static computer-assisted implant surgery [J].
El Kholy, Karim ;
Ebenezer, Supriya ;
Wittneben, Julia-Gabriela ;
Lazarin, Rafael ;
Rousson, Dominique ;
Buser, Daniel .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (05) :1073-1079
[7]   Influence of surgical guide support and implant site location on accuracy of static Computer-Assisted Implant Surgery [J].
El Kholy, Karim ;
Lazarin, Rafael ;
Janner, Simone F. M. ;
Faerber, Karin ;
Buser, Ramona ;
Buser, Daniel .
CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (11) :1067-1075
[8]   The influence of guided sleeve height, drilling distance, and drilling key length on the accuracy of static Computer-Assisted Implant Surgery [J].
El Kholy, Karim ;
Janner, Simone F. M. ;
Schimmel, Martin ;
Buser, Daniel .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (01) :101-107
[9]   Additively Manufactured Surgical Implant Guides: A Review [J].
Elliott, Tom ;
Hamilton, Adam ;
Griseto, Neil ;
Gallucci, German O. .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 :38-46
[10]   Three-dimensional facial esthetics-driven computer-assisted osteotomy and implant placement for immediate restoration of a failing dentition with a protruded maxilla [J].
Fu, Xiaojiao ;
Yang, Jingwen ;
Luo, Jia ;
Zhang, Yu .
JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (03) :392-397