Identification of Hand Tremor Levels in Shooting Activities Under Different Shooting Positions Using a Low-Cost and Portable System

被引:0
|
作者
Saputra, Jeki [1 ]
Santoso, Didik Rahadi [1 ]
Dharmawan, Hari Arief [1 ]
Hasanah, Rini Nur [1 ]
机构
[1] Brawijaya Univ, Jl Vet, Malang 65145, Indonesia
关键词
Accuracy; Hand tremor; Hand vibration; Shooting position; RIFLE; EXPERTISE;
D O I
10.14429/dsj.74.19111
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The accuracy level is important in shooting activities and depends on many factors, such as hand tremors as body vibration and shooting position. Achieving high accuracy in different shooters is challenging, especially in the case of different shooting positions. However, there is a lack of information about the influence of shooting positions and experiences on a shooter's body vibration and accuracy levels. Thus, this study aims to develop a portable and low-cost hand tremor measurement device (as a function of body vibration) to identify the influence of hand movement on shooting accuracy. For this purpose, low-cost accelerometer sensors and a microcontroller were used as the measurement kit. Three different shooting positions (squatting, standing, and prone) were analyzed. The shooters were classified into novice and expert groups. Each group had five participants with standard fire guns and accelerometer kits. These participants were asked to shoot the target to get their best accuracy. Besides, the hand tremor level data from the self-developed kit were recorded to investigate the hand tremors. The results show that the novice participants have more hand tremors in all shooting positions. There are significant differences between the squatting, standing, and prone positions in hand tremors for novice and expert participants. In the expert group, the prone and squatting positions have the least vibration level, indicated by the least acceleration (0.01 - 0.04 m/s2 for the expert group and 0.02 - 0.11 m/s2 for the novice group). The best accuracy for all positions is also obtained from expert shooters. It can be concluded that different shooting positions are related to the body vibrations. The expert shooters have a lower body vibration than the novice participants. The hand tremor levels may influence the accuracy level since different shooting positions and experiences have different vibration and accuracy levels.
引用
收藏
页码:256 / 262
页数:7
相关论文
共 47 条
  • [1] Evolutionary low-cost visual shooting practice system
    20161902358439
    (1) Mechanical Eng. Department, Jordan University of Science and Technology, Irbid, Jordan; (2) Electromechanical Engineering, Technology Department/ Institute of Applied Technology, Abu-Dhabi, United Arab Emirates; (3) Department of Mechatronics Engineering, Philadelphia University, Jerash, Jordan, 1600, Emirates Global Aluminium (EGA) (Institute of Electrical and Electronics Engineers Inc., United States):
  • [2] Evolutionary Low-Cost Visual Shooting Practice System
    Hatamleh, Khaled S.
    Khasawneh, Qais A.
    Sawaqed, Laith
    Hassan, Mohammad M.
    Yafawi, Sarah
    Al-Shabi, Mohammad
    2015 10th International Symposium on Mechatronics and its Applications (ISMA), 2015,
  • [3] Low-Cost Weed Identification System Using Drones
    Liang, Wei-Che
    Yang, You-Jei
    Chao, Chih-Min
    2019 SEVENTH INTERNATIONAL SYMPOSIUM ON COMPUTING AND NETWORKING WORKSHOPS (CANDARW 2019), 2019, : 260 - 263
  • [4] Graffiti Identification System Using Low-Cost Sensors
    Garcia Garcia, Miguel
    Gonzalez Arrieta, Angelica
    Rodriguez Gonzalez, Sara
    Marquez-Sanchez, Sergio
    Da Silva Ramos, Carlos Fernando
    INTERNATIONAL JOURNAL OF INTERACTIVE MULTIMEDIA AND ARTIFICIAL INTELLIGENCE, 2024, 8 (06): : 51 - 60
  • [5] Development of a Low-Cost Portable Device for Identification of Parathyroid Glands Using Autofluorescence
    Serra, Carlos
    Silveira, Luis
    Canudo, Antonio
    INDIAN JOURNAL OF SURGERY, 2020, 82 (06) : 1126 - 1130
  • [6] Low-Cost and Portable Impedance Plethysmography System for the Simultaneous Detection of Respiratory and Heart Activities
    Piuzzi, Emanuele
    Pisa, Stefano
    Pittella, Erika
    Podesta, Luca
    Sangiovanni, Silvia
    IEEE SENSORS JOURNAL, 2019, 19 (07) : 2735 - 2746
  • [7] Development of a Low-Cost Portable Device for Identification of Parathyroid Glands Using Autofluorescence
    Carlos Serra
    Luís Silveira
    António Canudo
    Indian Journal of Surgery, 2020, 82 : 1126 - 1130
  • [8] Low-cost backpack-portable robot system for mine and UXO detection and identification
    Nelson, CV
    Arabian, AK
    DETECTION AND REMEDIATION TECHNOLOGIES FOR MINES AND MINELIKE TARGETS VII, PTS 1 AND 2, 2002, 4742 : 574 - 582
  • [9] Identification of adulteration in uncooked Jasmine rice by a portable low-cost artificial olfactory system
    Timsorn, Kriengkri
    Lorjaroenphon, Yaowapa
    Wongchoosuk, Chatchawal
    MEASUREMENT, 2017, 108 : 67 - 76
  • [10] A low-cost, portable biopotential monitoring system to study electrical activities of the human brain and body
    Bandara, Vibodha
    Nanayakkara, Asiri
    EUROPEAN JOURNAL OF PHYSICS, 2020, 41 (06)