Efficacy and safety of radiofrequency ablation versus cryoballoon ablation for persistent atrial fibrillation: a systematic review and meta-analysis of randomized controlled trials

被引:1
作者
Amin, Ahmed Mazen [1 ]
Nawlo, Ahmad [2 ]
Ibrahim, Ahmed A. [3 ]
Hassan, Ahmed [4 ,8 ]
Saber, Alhassan [5 ]
Abuelazm, Mohamed [6 ]
Abdelazeem, Basel [7 ]
机构
[1] Mansoura Univ, Fac Med, Mansoura, Egypt
[2] Harvard Med Sch, Brigham & Womens Hosp, Div Infect Dis, Boston, MA 02115 USA
[3] Menoufia Univ, Fac Med, Saad Zaghloul St Shebin, Menoufia 32511, Egypt
[4] October 6 Univ, Fac Med, Giza, Egypt
[5] Minia Univ, Fac Med, Al Minya, Egypt
[6] Tanta Univ, Fac Med, Tanta, Egypt
[7] West Virginia Univ, Dept Cardiol, Morgantown, WV 26506 USA
[8] Minist Hlth & Populat, Dept Cardiol, Suez Med Complex, Suez, Egypt
关键词
Ablation; Atrial fibrillation; Pulmonary vein isolation; Arrhythmia; Review; PULMONARY VEIN ISOLATION; CATHETER ABLATION; QUALITY; GRADE;
D O I
10.1186/s43044-024-00518-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Persistent Atrial Fibrillation (PeAF) is a challenging case for rhythm control modalities. Catheter ablation is the mainstay in PeAF management; however, data regarding the comparative safety and efficacy of cryoballoon ablation (CBA) versus radiofrequency ablation (RFA) for PeAF is still limited. We aim to compare the safety and efficacy of CBA versus RFA for PeAF ablation. Methods We conducted a systematic review and meta-analysis synthesizing randomized controlled trials (RCTs), which were retrieved by systematically searching PubMed, EMBASE, Web of Science, SCOPUS, and Cochrane through October 2023. RevMan version 5.4 software was used to pool dichotomous data using risk ratio (RR) and continuous data using mean difference (MD) with a 95% confidence interval (CI). PROSPERO ID: CRD42023480314. Results Three RCTs with 400 patients were included. There was no significant difference between RFA and CBA regarding AF recurrence (RR: 0.77, 95% CI [0.50, 1.20], P = 0.25), atrial tachycardia or atrial flutter recurrence (RR: 0.54, 95% CI [0.11, 2.76], P = 0.46), and any arrhythmia recurrence (RR: 0.96, 95% CI [0.70, 1.31], P = 0.80). CBA was significantly associated with decreased total procedure duration (MD: - 45.34, 95% CI [- 62.68, - 28.00], P < 0.00001), with no significant difference in fluoroscopy duration (MD: 3.59, 95% CI [- 5.13, 12.31], P = 0.42). Safety parameters were similar in both groups, including the incidence of any complications, phrenic nerve palsy (RR: 2.91 with 95% CI [0.31, 27.54], P = 0.35), access site complications (RR: 0.33 with 95% CI [0.05, 2.03], P = 0.23), and pericardial effusion. Conclusions In PeAF catheter ablation, CBA is comparable to RFA in terms of safety and efficacy. Also, CBA is associated with a shorter total procedure duration.
引用
收藏
页数:13
相关论文
共 27 条
[1]   Efficacy and safety of high-power short-duration ablation for atrial fibrillation: a systematic review and meta-analysis of randomized controlled trials [J].
Amin, Ahmed Mazen ;
Ghaly, Ramy ;
Ibrahim, Ahmed A. ;
Ali, Mohamed Ahmed ;
Almaadawy, Omar ;
Elzahaby, Amr ;
Abuelazm, Mohamed ;
Abdelazeem, Basel ;
Munir, Muhammad Bilal .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (06) :1445-1461
[2]   Cryoballoon or Radiofrequency Ablation for Atrial Fibrillation Assessed by Continuous Monitoring A Randomized Clinical Trial [J].
Andrade, Jason G. ;
Champagne, Jean ;
Dubuc, Marc ;
Deyell, Marc W. ;
Verma, Atul ;
Macle, Laurent ;
Leong-Sit, Peter ;
Novak, Paul ;
Badra-Verdu, Mariano ;
Sapp, John ;
Mangat, Iqwal ;
Khoo, Clarence ;
Steinberg, Christian ;
Bennett, Matthew T. ;
Tang, Anthony S. L. ;
Khairy, Paul ;
Parkash, Ratika ;
Guerra, Peter ;
Dyrda, Katia ;
Rivard, Lena ;
Racine, Normand ;
Sterns, Lawrence ;
Leather, Rick ;
Seifer, Colette ;
Jolly, Umjeet ;
Raymond, Jean-Marc ;
Roux, Jean-Francois ;
Nault, Isabelle ;
Sarrazin, Jean-Francois ;
Ramanathan, Krishnan ;
Cheung, Christopher ;
Fordyce, Christopher ;
McKinney, Jimmy ;
Luong, Christina ;
Rizkallah, Jacques ;
Angaran, Paul ;
Ha, Andrew ;
Glover, Benedict ;
Skanes, Allan ;
Gula, Lorne .
CIRCULATION, 2019, 140 (22) :1779-1788
[3]  
[Anonymous], RevMan | Cochrane Training
[4]   Comparative Effectiveness and Safety of Cryoablation Versus Radiofrequency Ablation Treatments for Persistent Atrial Fibrillation [J].
Baimbetov, Adil K. ;
Bizhanov, Kenzhebek A. ;
Jukenova, Aiman M. ;
Aubakirova, Aigul T. ;
Ualiyeva, Aliya Ye. ;
SagatovDr, Inkar Ye. .
AMERICAN JOURNAL OF CARDIOLOGY, 2022, 184 :22-30
[5]   Pulmonary vein isolation as index procedure for persistent atrial fibrillation: One-year clinical outcome after ablation using the second-generation cryoballoon [J].
Ciconte, Giuseppe ;
Ottaviano, Luca ;
Deasmundis, Carlo ;
Baltogiannis, Giannis ;
Conte, Giulio ;
Sieira, Juan ;
Di Giovanni, Giacomo ;
Saitoh, Yukio ;
Irfan, Ghazala ;
Mugnai, Giacomo ;
Storti, Cesare ;
Montenero, Annibale Sandro ;
Chierchia, Gian-Battista ;
Brugada, Pedro .
HEART RHYTHM, 2015, 12 (01) :60-66
[6]   Improved Procedural Efficacy of Pulmonary Vein Isolation Using the Novel Second-Generation Cryoballoon [J].
Fuernkranz, Alexander ;
Bordignon, Stefano ;
Schmidt, Boris ;
Gunawardene, Melanie ;
Schulte-Hahn, Britta ;
Urban, Verena ;
Bode, Frank ;
Nowak, Bernd ;
Chun, Julian K. R. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (05) :492-497
[7]   Multi-catheter cryotherapy compared with radiofrequency ablation in long-standing persistent atrial fibrillation: a randomized clinical trial [J].
Gallagher, Mark M. ;
Yi, Gang ;
Gonna, Hanney ;
Leung, Lisa W. M. ;
Harding, Idris ;
Evranos, Banu ;
Bastiaenen, Rachel ;
Sharma, Rajan ;
Wright, Sue ;
Norman, Mark ;
Zuberi, Zia ;
Camm, A. John .
EUROPACE, 2021, 23 (03) :370-379
[8]   GRADE:: what is "quality of evidence" and why is it important to clinicians? [J].
Guyatt, Gordon H. ;
Oxman, Andrew D. ;
Vist, Gunn E. ;
Kunz, Regina ;
Falck-Ytter, Yngve ;
Schunemann, Holger .
BMJ-BRITISH MEDICAL JOURNAL, 2008, 336 (7651) :995-999B
[9]   GRADE:: an emerging consensus on rating quality of evidence and strength of recommendations [J].
Guyatt, Gordon H. ;
Oxman, Andrew D. ;
Vist, Gunn E. ;
Kunz, Regina ;
Falck-Ytter, Yngve ;
Alonso-Coello, Pablo ;
Schuenemann, Holger J. .
BRITISH MEDICAL JOURNAL, 2008, 336 (7650) :924-926
[10]   Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins [J].
Haïssaguerre, M ;
Jaïs, P ;
Shah, DC ;
Takahashi, A ;
Hocini, M ;
Quiniou, G ;
Garrigue, S ;
Le Mouroux, A ;
Le Métayer, P ;
Clémenty, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (10) :659-666