Diagnostic values of SurePath liquid-based cytology versus conventional smear in thyroid aspiration samples: A 13-year experience at a single institution

被引:1
作者
Lee, Wen-Ying [1 ,2 ]
Wang, Hsiu-Chu [1 ]
Huang, Lee-E [1 ]
Tseng, Min-Hui [1 ]
Chiang, Shu-Hui [1 ]
Lee, Ching-Chien [1 ]
机构
[1] Chi Mei Med Ctr, Dept Pathol, Div Cytopathol, Tainan, Taiwan
[2] Chi Mei Med Ctr, Dept Pathol, Div Cytopathol, 901 Chung Hwa Rd, Tainan 71004, Taiwan
关键词
Bethesda system; conventional smear; diagnostic values; fine-needle aspiration cytology; liquid-based cytology; SurePath; TBSRTC; thyroid; FINE-NEEDLE-ASPIRATION; BETHESDA SYSTEM; BIOPSY; CYTOPATHOLOGY; MALIGNANCY; MANAGEMENT; ACCURACY; NODULES; LESIONS;
D O I
10.1002/dc.25319
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Fine needle aspiration cytology (FNAC) is the most useful tool in the diagnosis of thyroid nodules. Liquid-based cytology (LBC) is replacing the conventional smear (CS) for evaluation of thyroid FNAC. In our institution, thyroid FNAC preparation was changed from CS to LBC SurePath in July 2016. This study aimed to compare the diagnostic value of SurePath with that of CS in thyroid lesions. Methods: A total of 35,406 samples of thyroid FNAC (11,438 CS and 23,968 SurePath), collected from January 2010 to December 2022, were included in this study. We also examined the malignant rate using the surgical pathology diagnosis as the gold standard. Results: The distribution of TBSRTC cytological categories was equivalent between CS and SurePath. The rate of nondiagnostic/unsatisfactory category was higher in CS compared to SurePath (43.4% vs. 22.3%; p < .05). After routine use of SurePath, the surgical resection rate was reduced from 12.0% to 8.6% (p < .05) and the malignant rate increased from 32.2% to 41.5% (p < .05). The sensitivities of CS and SurePath were 71.0% and 82.0%, respectively, and the specificities were 99.0% and 97.3%, respectively, whereas the positive predictive values were 97.8% and 96.8%, respectively, and the negative predictive values were 85.0% and 84.6%, respectively. Diagnostic accuracy of CS and SurePath were 88.5% and 89.7% respectively. Conclusion: SurePath can increase the sample adequacy, increase the sensitivity and reduce the workload and avoid unnecessary surgeries with similar accuracy to CS.
引用
收藏
页码:369 / 376
页数:8
相关论文
共 39 条
[1]  
Amrikachi M, 2001, ARCH PATHOL LAB MED, V125, P484
[2]   The Bethesda System for Reporting Thyroid Cytopathology: A Meta-Analysis [J].
Bongiovanni, Massimo ;
Spitale, Alessandra ;
Faquin, William C. ;
Mazzucchelli, Luca ;
Baloch, Zubair W. .
ACTA CYTOLOGICA, 2012, 56 (04) :333-339
[3]   Thyroid fine-needle aspiration cytology in Taiwan: a nationwide survey and literature update [J].
Chen, Chien-Chin ;
Hang, Jen-Fan ;
Liu, Chih-Yi ;
Wang, Yeh-Han ;
Lai, Chiung-Ru .
JOURNAL OF PATHOLOGY AND TRANSLATIONAL MEDICINE, 2020, 54 (05) :361-366
[4]  
Cibas Edmund S, 2017, J Am Soc Cytopathol, V6, P217, DOI 10.1016/j.jasc.2017.09.002
[5]   The Bethesda System for Reporting Thyroid Cytopathology [J].
Cibas, Edmund S. ;
Ali, Syed Z. .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2009, 132 (05) :658-665
[6]   Diagnostic accuracy of fine needle aspiration cytology of thyroid nodules [J].
Erkinuresin, Taskin ;
Demirci, Hakan .
DIAGNOSIS, 2020, 7 (01) :61-66
[7]   Low Malignancy Rates in Fine-Needle Aspiration Cytologies in a Primary Care Setting in Germany [J].
Eszlinger, Markus ;
Ullmann, Maha ;
Ruschenburg, Ilka ;
Boehme, Katharina ;
Goerke, Fabian ;
Franzius, Christiane ;
Adam, Sabine ;
Molwitz, Thomas ;
Landvogt, Christian ;
Amro, Bassam ;
Hach, Anja ;
Feldmann, Berit ;
Graf, Dieter ;
Wefer, Antje ;
Niemann, Rainer ;
Bullmann, Catharina ;
Klaushenke, Guenther ;
Santen, Reinhard ;
Toenshoff, Gregor ;
Ivancevic, Velimir ;
Koegler, Andreas ;
Bell, Eberhard ;
Lorenz, Bernd ;
Kluge, Gerald ;
Hartenstein, Christoph ;
Paschke, Ralf .
THYROID, 2017, 27 (11) :1385-1392
[8]   Liquid-Based Cytology in Fine-Needle Aspiration Biopsies of the Thyroid Gland [J].
Fadda, Guido ;
Rossi, Esther Diana .
ACTA CYTOLOGICA, 2011, 55 (05) :389-400
[9]   Liquid-Based FNAC of the Thyroid A 4-year Survey With SurePath [J].
Geers, Caroline ;
Bourgain, Claire .
CANCER CYTOPATHOLOGY, 2011, 119 (01) :58-67
[10]   Accuracy of Thyroid Fine-Needle Aspiration Cytology: A Cyto-Histologic Correlation Study in an Integrated Canadian Health Care Region with Centralized Pathology Service [J].
Ghaznavi, Sana A. ;
Clayton, Hailey ;
Eszlinger, Markus ;
Khalil, Moosa ;
Symonds, Christopher J. ;
Paschke, Ralf .
ACTA CYTOLOGICA, 2022, 66 (03) :171-178