Off-design performance of gas turbine power units with alternative load-control strategies

被引:0
|
作者
Pan Z. [1 ]
Lin Z. [1 ]
Fan K. [2 ]
Yang C. [2 ]
Ma X. [2 ]
机构
[1] Guangzhou Zhujiang LNG Power Generation Co., Ltd., Guangzhou
[2] School of Electric Power, South China University of Technology, Guangzhou
关键词
Comparative simulation; Gas turbine; Operating strategy; Part load performance;
D O I
10.32604/EE.2020.013585
中图分类号
学科分类号
摘要
Gas turbine power units, as an effective way to cope with the severe challenge of renewable energy accommodation in power grids, arouse the interest of power enterprises in the deep peak-load regulation performance. Two common alternative load-control strategies including constant turbine inlet temperature (TIT) and constant turbine exhaust temperature (TET) regulations were taken into consideration. To comparatively investigate the part-load performance under these strategies, both mathematical and physical models were set up successively to serve as a validation and complementary to each other. For the mathematical model of compressor with inlet guide vane (IGV), combustor and turbine, stage-stacking method based on blade average geometric parameter, energy con-servation and turbine stage model were adopted respectively. For the physical model, design and off-design analysis were carried out based on GT PRO and THERMOFLEX respectively. The simulation result of mathematical model vali-dated the reliability of the physical model. Based on this, the influence of ambient temperature and different load-regulating strategies on the off-design performance of gas turbine power units was studied in THERMOFLEX. The results in the case of a PG 9351FA gas turbine show that the ambient temperature has a great impact on system performance, i.e., every 5°C increase in the ambient temperature pro-duces a reduction of 3.7% in the relative full-load output and 1.1% in the relative efficiency respectively; when the gas turbine operates under constant TIT strategy, TET starts to rise till it reaches the maximum allowable value with the load rate decreasing, and IGV keeps at the minimum angle with both TIT and TET decreasing when the load rate is lower than 65%; when the gas turbine operates under constant TET strategy, TIT drops slightly at load rate of above 60% while both TIT and TET evidently decrease below 60% load rate operating along the constant corrected speed line at the minimum allowable IGV opening; gas turbine efficiency is greatly affected by load rate and the performance degradation is more obvious especially in lower load rate regions; constant TET strategy is superior in the operating efficiency to constant TIT strategy under part-load conditions. © 2021, Tech Science Press. All rights reserved.
引用
收藏
页码:119 / 141
页数:22
相关论文
共 50 条
  • [41] Aerodynamic performance of a transonic turbine cascade at off-design conditions
    Jouini, DBM
    Sjolander, SA
    Moustapha, SH
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2001, 123 (03): : 510 - 518
  • [42] OFF-DESIGN PERFORMANCE PREDICTION OF STEAM TURBINE-GENERATORS
    LARSON, VH
    GORLA, RSR
    MECHANICAL ENGINEERING, 1983, 105 (12) : 89 - 90
  • [43] THE OFF-DESIGN PERFORMANCE OF A LOW-PRESSURE TURBINE CASCADE
    HODSON, HP
    DOMINY, RG
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1987, 109 (02): : 201 - 209
  • [44] Environmental thermoeconomic performance analysis of gas turbine combined cycle under off-design conditions
    Wang, Zhen
    Duan, Liqiang
    Zhang, Zuxian
    ENERGY SCIENCE & ENGINEERING, 2023, 11 (01) : 127 - 142
  • [45] Performance Analysis in Off-Design Condition of Gas Turbine Air-Bottoming Combined System
    Carcasci, Carlo
    Costanzi, Federico
    Pacifici, Beniamino
    ATI 2013 - 68TH CONFERENCE OF THE ITALIAN THERMAL MACHINES ENGINEERING ASSOCIATION, 2014, 45 : 1037 - 1046
  • [46] Design and off-design optimisation of highly loaded industrial gas turbine stages
    Amos, IG
    Jablonowski, T
    Rossi, E
    Vogt, D
    Boncinelli, P
    APPLIED THERMAL ENGINEERING, 2004, 24 (11-12) : 1735 - 1744
  • [47] Off-design performance analysis of a humid air turbine based on a micro turbine
    Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing 100080, China
    Kung Cheng Je Wu Li Hsueh Pao, 2006, 4 (545-548):
  • [48] Design and Off-Design Analysis of an ORC Coupled with a Micro-Gas Turbine
    Benato, Alberto
    Stoppato, Anna
    Mirandola, Alberto
    Del Medico, Marco
    4TH INTERNATIONAL SEMINAR ON ORC POWER SYSTEMS, 2017, 129 : 551 - 558
  • [49] Improved Method for Gas-Turbine Off-Design Performance Adaptation Based on Field Data
    Li, Shiyao
    Li, Zhenlin
    Li, Shuying
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2020, 142 (04):
  • [50] Performance analysis of partially recuperative gas turbine combined cycle under off-design conditions
    Liu, Taohong
    Zhang, Guoqiang
    Li, Yongyi
    Yang, Yongping
    ENERGY CONVERSION AND MANAGEMENT, 2018, 162 : 55 - 65