In vitro experiment on relationship between erythrocyte deformability and hemolysis during blood circulation in a hemodialysis circuit

被引:0
作者
Kohri S. [1 ]
Irino K. [2 ]
Tanaka K. [1 ]
Hatanaka Y. [1 ]
Tajikawa T. [3 ]
机构
[1] Department of Medical Engineering, Aino University
[2] Graduate School of Science and Engineering, Kansai University
[3] Department of Mechanical Engineering, Faculty of Engineering Sciencex, Faculty of Engineering Science, Kansai University
来源
Transactions of Japanese Society for Medical and Biological Engineering | 2020年 / 58卷 / 06期
关键词
Deformability; Erythrocyte; Hemodialysis; Hemolysis; In-vitro model experiment;
D O I
10.11239/jsmbe.58.230
中图分类号
学科分类号
摘要
In recent years, the number of hemodialysis patients is increasing due to population aging and lifestyle-related diseases, and hemodialysis lowers patients’ quality of life. The technique of hemodialysis was developed based on hemolysis, and it is thought that hemolysis in hemodialysis is induced during discharge by the peristaltic pump. However, studies have not investigated in detail whether hemolysis is instantaneously induced either by the pump or the accumulation of mechanical damage to erythrocytes. In this study, the deformability and degree of hemolysis of erythrocytes in extracorporeal circulation during hemodialysis were measured quantitatively, based on the mechanics of an in vitro model experiment using commercially available blood. In this experiment, the influence of drug administration to patients could be ignored. In the experiment, blood was circulated in a hemodialysis circuit model in which the parameters of flow rate and circulation time were set with reference to hemodialysis conditions in clinical settings. Blood for measurement was sampled from the circuit. The deformability of the sampled erythrocytes was evaluated based on the time constant of shape recovery, which was measured using two methods;the micro-channel and uni-axial stretching methods. Hemolysis was quantified based on absorbance measured using a spectrometer. The results showed that the deformability of erythrocytes remained nearly unchanged over time of hemodialysis when measured by both methods, whereas hemolysis increased in all conditions. These findings indicate that hemolysis is induced instantaneously by the peristaltic pump in the hemodialysis system. © 2020, Japan Soc. of Med. Electronics and Biol. Engineering. All rights reserved.
引用
收藏
页码:230 / 237
页数:7
相关论文
共 12 条
[1]  
Iwata J, Mori S, Ichikawa T, Uchida T, Hayashi H, Ishikura N, Nakano T, A study on hemolysis in hemodialysis patient, JJN, 31, 11, pp. 1163-1170, (1989)
[2]  
Kikuchi Y, Horimoto M, Koyama T, Koyama Y, Tozawa S, Estimation of pore passage time of red blood cells in normal subjects and patients with renal failure, Experientia, 36, pp. 325-327, (1980)
[3]  
Fukushima A, Hirayama N, Yamaya K, Suzuki T, Funyu T, Erythrocyte deformability in chronic hemodialysis patients, J Jpn Soc Dialysis Ther, 17, 4, pp. 291-296, (1984)
[4]  
Shimizu T, Yamaguchi H, Tsuchida H, Motoyasu S, Hakoshima A, Akimoto N, Hino H, Hirayama T, Kitamura M, Ishimaru S, Koike S, Furukawa K, Takahashi M, Fujino M, Azuma N, Suzuki M, Anemia and Red Cell Deformability in patient with chronic renal failure, Jpn J Artif Organs, 15, 3, pp. 1330-1333, (1986)
[5]  
Tsukada K, Sekizuka E, Oshio C, Minamitani H, Direct measurement of erythrocyte deformability in diabetes mellitus with a transparent microchannel capillary model and high-speed video camera system, Microvasc Res, 61, 3, pp. 231-239, (2001)
[6]  
Brown CD, Ghali HS, Zhao Z, Thomas LL, Friedman EA, Association of reduced red blood cell deformability and diabetic nephropathy, Kidney Int, 67, pp. 295-300, (2005)
[7]  
Irino K, Tajikawa T, Kohri S, Hatanaka Y, In vitro evaluation on influence of dialysis treatment on erythrocyte deformability and hemolytic property, Proc. of Conference of Kansai Branch, 94, (2019)
[8]  
Wada F, Ono T, Ikeda C, Yakubutsu Touyo ga Hemoglobin no Kinou ni Oyobosu Eikyou, Folia Pharmacol Japon, 77, 5, pp. 447-458, (1981)
[9]  
Inui T, Tajikawa T, Ikemoto T, Takeuchi T, Quantitative evaluation of human erythrocyte deformability by using a sheath flow micro-channel (Relationship between apparent shape recovery time and dynamic viscosity of single cell suspension), B & R, 31, 2, (2017)
[10]  
Kohri S, Kato Y, Tajikawa T, Yamamoto Y, Bando K, Measurement of erythrocyte deformability by uniaxial stretchingmeasurement of apparent Young’s modulus and time constant of shape recovering, Trans Jpn Soc Med Biol Eng, 53, 1, pp. 1-7, (2015)