Evaluating the strength of evidence of elemental profiling of polymers with LA-ICP-MS

被引:3
作者
de Bruin-Hoegee, Mirjam [1 ,2 ]
Corzo, Ruthmara [3 ]
Zoon, Peter D. [4 ]
Vergeer, Peter [4 ]
Schoorl, Jorien [4 ]
van der Schans, Marcel J. [2 ]
Noort, Daan [2 ,6 ]
van Asten, Arian C. [1 ,5 ]
机构
[1] Univ Amsterdam, Vant Hoff Inst Mol Sci, Fac Sci, POB 94157, NL-1090GD Amsterdam, Netherlands
[2] TNO Def Safety & Secur, Dep CBRN Protect, Lange Kleiweg 137, NL-2288GJ Rijswijk, Netherlands
[3] Natl Inst Stand & Technol, Mat Measurement Sci Div, Gaithersburg, MD 20899 USA
[4] Netherlands Forens Inst, POB 24044, NL-2490 AA The Hague, Netherlands
[5] Univ Amsterdam, Amsterdam Ctr Forens Sci & Med, CLHC, POB 94157, NL-1090GD Amsterdam, Netherlands
[6] Org Prohibit Chem Weap, Johan de Wittlaan 32, NL-2517 JR The Hague, Netherlands
关键词
Chemical attribution signatures; Polymers; Laser ablation-inductively coupled plasma; Likelihood ratio; Elemental profiling; Forensic chemistry; mass spectrometry (LA-ICP-MS); PLASMA-MASS SPECTROMETRY; GLASS FRAGMENTS; FORENSIC GLASS; TAPE BACKINGS; PERFORMANCE; VALIDATION;
D O I
10.1016/j.forc.2024.100570
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
LA-ICP-MS is a powerful technique for obtaining a forensic elemental profile of polymer evidence materials. However, the lack of homogeneous polymer reference standards hampers database creation and reliably matching a sample to a specific source. Therefore, the current study aims to evaluate the strength of evidence of forensic polymer comparisons by applying a matrix-matched reference standard with known concentrations for elements of interest. Four datasets of tapes, electrical wires, tubing, and jerrycans were compiled using LA-ICPMS. It was found that quantification with the new PVC standard or by simply using the response of one element as internal standard significantly reduced the between-run variation. For each class of polymeric materials, characteristic elements could be identified with PCA and LDA. To facilitate classification, elemental concentrations were found to be typical for specific colors and types of polymeric materials. For forensic comparison, a score-based Bayesian likelihood ratio model and the t-test overlap method performed better than the featurebased model and 4-sigma criterion, in terms of rates of misleading evidence. Normalization to 13C and quantification with the PVC standard with and without prior normalization to 13C slightly reduced rates of misleading evidence. The t-test method showed an overall average false inclusion rate of only 0.45% and a false exclusion rate of 2.4%. Maximum calibrated likelihood ratios of 0.014 to 1778 were found for the tape dataset. In conclusion, this study demonstrates that with the use of proper standards, quantitative elemental profiling with LA-ICP-MS is a promising tool for forensic classification and comparison of polymers.
引用
收藏
页数:11
相关论文
共 46 条
[1]   Evaluation of trace evidence in the form of multivariate data [J].
Aitken, CGG ;
Lucy, D .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES C-APPLIED STATISTICS, 2004, 53 :109-122
[2]   Perspectives on additives for polymers. Part 2. Aspects of photostabilization and role of fillers and pigments [J].
Allen, Norman S. ;
Edge, Michele .
JOURNAL OF VINYL & ADDITIVE TECHNOLOGY, 2021, 27 (02) :211-239
[3]   Applications of LA-ICP-MS to Forensic Science [J].
Almirall, Jose R. ;
Trejos, Tatiana .
ELEMENTS, 2016, 12 (05) :335-340
[4]  
[Anonymous], 2012, Certificate of Analysis: Standard Reference Material 3151
[5]  
ASTM International, 2016, ASTM E2927-16e1
[6]   Forensic analysis of float glass using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS): validation of a method [J].
Berends-Montero, Shirly ;
Wiarda, Wim ;
de Joode, Peter ;
van der Peijl, Gerard .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (11) :1185-1193
[7]   Multicomponent characterization and differentiation of flash bangers - Part II: Elemental profiling of plastic caps [J].
Bezemer, Karlijn ;
Woortmeijer, Rikus ;
Koeberg, Mattijs ;
Wiarda, Wim ;
Schoenmakers, Peter ;
van Asten, Arian .
FORENSIC SCIENCE INTERNATIONAL, 2018, 290 :336-348
[8]   Evaluating score- and feature-based likelihood ratio models for multivariate continuous data: applied to forensic MDMA comparison [J].
Bolck, Annabel ;
Ni, Haifang ;
Lopatka, Martin .
LAW PROBABILITY & RISK, 2015, 14 (03) :243-266
[9]   The use of LA-ICP-MS databases to calculate analysis of glass evidence [J].
Corzo, Ruthmara ;
Hoffman, Tricia ;
Weis, Peter ;
Franco-Pedroso, Javier ;
Ramos, Daniel ;
Almirall, Jose .
TALANTA, 2018, 186 :655-661
[10]   A novel standard for forensic elemental profiling of polymers by LA-ICP-TOF-MS [J].
de Bruin-Hoegee, Mirjam ;
Schoorl, Jorien ;
Zoon, Peter ;
Schans, Marcel J. van der ;
Noort, Daan ;
Asten, Arian C. van .
FORENSIC CHEMISTRY, 2023, 35