Efficacy of LigaSure Versus Harmonic Devices in Laparoscopic Sleeve Gastrectomy: A Systematic Review and Meta-Analysis

被引:1
作者
Alharran, Abdullah M. [1 ]
Alenezi, Yaqoub Y. [1 ]
Hammoud, Sabri M. [2 ]
Alshammari, Bandar [3 ]
Alrashidi, Mohammed [3 ]
Alyaqout, Fajer B. [1 ]
Almarri, Abdulhadi [1 ]
Alharran, Yousef M. [4 ]
Alazemi, Mohammed H. [4 ]
Allafi, Fahad [5 ]
Al Sadder, Khaled Ahmad [6 ]
机构
[1] Arabian Gulf Univ, Coll Med, Med & Surg, Manama, Bahrain
[2] Jaber Alahmad Hosp, Gen Surg, Kuwait, Kuwait
[3] Univ Jordan, Fac Med, Med & Surg, Amman, Jordan
[4] Alexandria Univ, Fac Med, Med & Surg, Alexandria, Romania
[5] Jahra Hosp, Gen Surg, Jahra, Kuwait
[6] Minist Hlth, Gen Surg, Kuwait, Kuwait
关键词
sleeve gastrectomy; laparoscopic sleeve gastrectomy; systematic review and meta-analysis; gastrectomy; harmonic; ligasure; BARIATRIC SURGERY; WEIGHT-LOSS; SCALPEL;
D O I
10.7759/cureus.57478
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Our goal is to conduct a thorough systematic review and meta-analysis of comparative studies to evaluate the efficacy of LigaSure (Valleylab, Boulder, CO) compared with Harmonic (Ethicon Endo-Surgery, Inc., Cincinnati, OH) devices in patients undergoing laparoscopic sleeve gastrectomy (LSG). Our search strategy, from inception until March 1, 2024, involved multiple databases, including the Cochrane Controlled Register of Trials (CENTRAL), Web of Science (WOS), PubMed, Scopus, and Google Scholar. We evaluated randomized clinical trials using the Cochrane Risk of Bias tool for randomized trials (RoB-2) tool and nonrandomized studies using the Risk of Bias In Non-randomized Studies for Interventions (ROBINS -I) tool. The primary outcomes assessed were operative time, mean length of hospital stay, and the rates of intraoperative complications such as bleeding, organ injury, leakage, and hematoma formation. Additionally, we collected data on postoperative complications, including bleeding, abscess formation, leakage, fever (>38 degrees C), and reoperation rates. Data were analyzed using random-effects models and reported as mean difference (MD) or risk ratio (RR) with a 95% confidence interval (CI) using Review Manager software (RevMan, version 5.4 for Windows, The Cochrane Collaboration, 2020). Four studies, comprising two randomized clinical trials (RCTs) and two retrospective cohort studies, involving a total of 692 patients, were included in the analysis. Both the operative time and length of hospital stay did not significantly differ between the LigaSure and Harmonic groups (p>0.05). The pooled analysis also revealed no significant difference between the LigaSure and Harmonic groups in terms of intraoperative and postoperative complications (p>0.05). In conclusion, our systematic review and meta-analysis found no significant statistical or clinical differences between LigaSure and Harmonic devices in terms of operative outcomes and complication rates in patients undergoing LSG.
引用
收藏
页数:10
相关论文
共 25 条
[1]   Harmonic Scalpel Tonsillectomy Versus Coblation Tonsillectomy: A Systematic Review and Meta-Analysis of Randomized Controlled Trials [J].
Albazee, Ebraheem ;
Hussain, Salman ;
Abduljabbar, Aysha ;
AlHajri, Maisem Tariq ;
Alsakka, Mahmoud Abdelaziz ;
Abu-Zaid, Ahmed .
INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY, 2023, 75 (04) :3621-3627
[2]   Efficacy of Harmonic Scalpel Versus Bipolar Diathermy in Hemorrhoidectomy: A Systematic Review and Meta-Analysis of Nine Randomized Controlled Trials [J].
Albazee, Ebraheem ;
Alenezi, Abdulaziz ;
Alenezi, Maryam ;
Alabdulhadi, Reham ;
Alhubail, Rawan J. ;
Al Sadder, Khaled Ahmad ;
AlDabbous, Fatma ;
Almutairi, Abdulrahman N. ;
Almutairi, Saad N. ;
Almutairi, Abdullah N. ;
Alenezi, Mujahed S. .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (02)
[3]   Common weight loss procedures and their complications [J].
Altieri, Maria S. ;
Wright, Brian ;
Peredo, Andrew ;
Pryor, Aurora D. .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2018, 36 (03) :475-479
[4]   Electrothermal bipolar vessel sealing device vs. ultrasonic coagulating shears in laparoscopic colectomies: a comparative study [J].
Campagnacci, Roberto ;
de Sanctis, Angelo ;
Baldarelli, Maddalena ;
Rimini, Massimiliano ;
Lezoche, Giovanni ;
Guerrieri, Mario .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2007, 21 (09) :1526-1531
[5]   Updated guidance for trusted systematic reviews: a new edition of the Cochrane Handbook for Systematic Reviews of Interventions [J].
Cumpston, Miranda ;
Li, Tianjing ;
Page, Matthew J. ;
Chandler, Jacqueline ;
Welch, Vivian A. ;
Higgins, Julian P. T. ;
Thomas, James .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2019, (10)
[6]   Laparoscopic reoperative sleeve gastrectomy for poor weight loss after biliopancreatic diversion with duodenal switch [J].
Gagner, M ;
Rogula, T .
OBESITY SURGERY, 2003, 13 (04) :649-654
[7]   Staple-line leak after sleve gastrectomy in obese patients: A hot topic in bariatric surgery [J].
Galloro, Giuseppe ;
Ruggiero, Simona ;
Russo, Teresa ;
Telesca, Donato Alessandro ;
Musella, Mario ;
Milone, Marco ;
Manta, Raffaele .
WORLD JOURNAL OF GASTROINTESTINAL ENDOSCOPY, 2015, 7 (09) :843-846
[8]   A novel dedicated endoscopic stent for staple-line leaks after laparoscopic sleeve gastrectomy: a case series [J].
Galloro, Giuseppe ;
Magno, Luca ;
Musella, Mario ;
Manta, Raffaele ;
Zullo, Angelo ;
Forestieri, Pietro .
SURGERY FOR OBESITY AND RELATED DISEASES, 2014, 10 (04) :607-611
[9]   Comparison of three different hemostatic devices in laparoscopic myomectomy. [J].
Huang, Hui-Yu ;
Liu, Yu-Cheng ;
Li, Yi-Chieh ;
Kuo, Hsin-Hong ;
Wang, Chin-Jung .
JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2018, 81 (02) :178-182
[10]   LigaSure™ 5-mm Blunt Tip Laparoscopic Instrument [J].
Karande V.C. .
The Journal of Obstetrics and Gynecology of India, 2015, 65 (5) :350-352