摘要
Background: Acetone, isoprene, and other volatile organic compounds (VOCs) in exhaled breath have been shown to be biomarkers for many medical conditions. Researchers use different techniques for VOC detection, including solid phase microextraction (SPME), to preconcentrate volatile analytes prior to instrumental analysis by gas chromatography-mass spectrometry (GC-MS). These techniques include a previously developed method to detect VOCs in breath directly using SPME, but it is uncommon for studies to quantify exhaled volatiles because it can be time consuming due to the need of many external/internal standards, and there is no standardized or widely accepted method. The objective of this study was to develop an accessible method to quantify acetone and isoprene in breath by SPME GC-MS. Results: A system was developed to mimic human exhalation and expose VOCs to a SPME fiber in the gas phase at known concentrations. VOCs were bubbled/diluted with dry air at a fixed flow rate, duration, and volume that was comparable to a previously developed breath sampling method. Identification of acetone and isoprene through GC-MS was verified using standards and observing overlaps in chromatographic retention/mass spectral fragmentation. Calibration curves were developed for these two analytes, which showed a high degree of linear correlation. Acetone and isoprene displayed limits of detection/quantification equal to 12 ppb/37 ppb and 73 ppb/222 ppb respectively. Quantification results in healthy breath samples (n = 15) showed acetone concentrations spanned between 71 ppb and 294 ppb, and isoprene varied between 170 ppb and 990 ppb. Both concentration ranges for acetone and isoprene in this study overlap with those reported in existing literature. Significance: Results indicate the development of a system to quantify acetone and isoprene in breath that can be adapted to diverse sampling methods and instrumental analyses beyond SPME GC -MS.
引用
收藏
页数:10
相关论文
共 60 条
[1]   Isoprene in the Exhaled Breath is a Novel Biomarker for Advanced Fibrosis in Patients with Chronic Liver Disease: A Pilot Study [J].
Alkhouri, Naim ;
Singh, Tavankit ;
Alsabbagh, Eyad ;
Guirguis, John ;
Chami, Tarek ;
Hanouneh, Ibrahim ;
Grove, David ;
Lopez, Rocio ;
Dweik, Raed .
CLINICAL AND TRANSLATIONAL GASTROENTEROLOGY, 2015, 6
[2]   Simultaneous analysis of 28 urinary VOC metabolites using ultra high performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (UPLC-ESI/MSMS) [J].
Alwis, K. Udeni ;
Blount, Benjamin C. ;
Britt, April S. ;
Patel, Dhrusti ;
Ashley, David L. .
ANALYTICA CHIMICA ACTA, 2012, 750 :152-160
[3]   The human volatilome: volatile organic compounds (VOCs) in exhaled breath, skin emanations, urine, feces and saliva [J].
Amann, Anton ;
Costello, Ben de Lacy ;
Miekisch, Wolfram ;
Schubert, Jochen ;
Buszewski, Boguslaw ;
Pleil, Joachim ;
Ratcliffe, Norman ;
Risby, Terence .
JOURNAL OF BREATH RESEARCH, 2014, 8 (03)
[4]   Measuring Breath Acetone for Monitoring Fat Loss: Review [J].
Anderson, Joseph C. .
OBESITY, 2015, 23 (12) :2327-2334
[5]   Canine Detection of the Volatilome: A Review of Implications for Pathogen and Disease Detection [J].
Angle, Craig ;
Waggoner, Lowell Paul ;
Ferrando, Arny ;
Haney, Pamela ;
Passler, Thomas .
FRONTIERS IN VETERINARY SCIENCE, 2016, 3
[6]   Noninvasive detection of lung cancer by analysis of exhaled breath [J].
Bajtarevic, Amel ;
Ager, Clemens ;
Pienz, Martin ;
Klieber, Martin ;
Schwarz, Konrad ;
Ligor, Magdalena ;
Ligor, Tomasz ;
Filipiak, Wojciech ;
Denz, Hubert ;
Fiegl, Michael ;
Hilbe, Wolfgang ;
Weiss, Wolfgang ;
Lukas, Peter ;
Jamnig, Herbert ;
Hackl, Martin ;
Haidenberger, Alfred ;
Buszewski, Boguslaw ;
Miekisch, Wolfram ;
Schubert, Jochen ;
Amann, Anton .
BMC CANCER, 2009, 9 :348
[7]   Breath Biopsy and Discovery of Exclusive Volatile Organic Compounds for Diagnosis of Infectious Diseases [J].
Belizario, Jose E. ;
Faintuch, Joel ;
Malpartida, Miguel Garay .
FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2021, 10
[8]   Determination of volatile organic compounds in exhaled breath of heart failure patients by needle trap micro-extraction coupled with gas chromatography-tandem mass spectrometry [J].
Biagini, D. ;
Lomonaco, T. ;
Ghimenti, S. ;
Bellagambi, F. G. ;
Onor, M. ;
Scali, M. C. ;
Barletta, V. ;
Marzilli, M. ;
Salvo, P. ;
Trivella, M. G. ;
Fuoco, R. ;
Di Francesco, F. .
JOURNAL OF BREATH RESEARCH, 2017, 11 (04)
[9]   Design and construction of a portable e-nose system for human exhaled breath VOC analysis [J].
Binson, V. A. ;
Akbar, Rizwana ;
Thankachan, Nisha ;
Thomas, Sania .
MATERIALS TODAY-PROCEEDINGS, 2022, 58 :422-427
[10]   Breath acetone as a marker of energy balance: an exploratory study in healthy humans [J].
Bovey, Fabian ;
Cros, Jeremy ;
Tuzson, Bela ;
Seyssel, Kevin ;
Schneiter, Philippe ;
Emmenegger, Lukas ;
Tappy, Luc .
NUTRITION & DIABETES, 2018, 8