Study of plasma parameters of coaxial plasma source using triple Langmuir probe and Faraday cup diagnostics
被引:1
|
作者:
论文数: 引用数:
h-index:
机构:
Kanchi, Sunil
[1
,2
]
Shukla, Rohit
论文数: 0引用数: 0
h-index: 0
机构:
Bhabha Atom Res Ctr, Pulsed Power & Electromagnet Div, Visakhapatnam 531011, India
Homi Bhabha Natl Inst, Mumbai 400085, IndiaBhabha Atom Res Ctr, Pulsed Power & Electromagnet Div, Visakhapatnam 531011, India
Shukla, Rohit
[1
,2
]
Sharma, Archana
论文数: 0引用数: 0
h-index: 0
机构:
Bhabha Atom Res Ctr, Pulsed Power & Electromagnet Div, Visakhapatnam 531011, India
Homi Bhabha Natl Inst, Mumbai 400085, India
Bhabha Atom Res Ctr, Beam Technol Dev Grp, Mumbai 400085, IndiaBhabha Atom Res Ctr, Pulsed Power & Electromagnet Div, Visakhapatnam 531011, India
Sharma, Archana
[1
,2
,3
]
机构:
[1] Bhabha Atom Res Ctr, Pulsed Power & Electromagnet Div, Visakhapatnam 531011, India
[2] Homi Bhabha Natl Inst, Mumbai 400085, India
[3] Bhabha Atom Res Ctr, Beam Technol Dev Grp, Mumbai 400085, India
Coaxial plasma guns are a type of plasma source that produces plasma which propagates radially and axially controlled by the shape of the ground electrode, which has attracted much interest in several applications. In this work, a 120 degrees opening angle of CPG nozzle is used as a plasma gun configuration that operates at the energy of 150 J. The ionization of polyethylene insulator between the electrodes of the gun produces a cloud of hydrogen and carbon plasma. The triple Langmuir probe and Faraday cup are used to measure plasma density and plasma temperature. These methods are used to measure the on-axis and off-axis plasma divergence of the coaxial plasma gun. The peak values of ion densities measured at a distance of 25 mm on-axis from the plasma gun are (1.6 0.5) 10 m and (2.8 0.6) 10 m for hydrogen and carbon plasma respectively and the peak temperature is 3.02 0.5 eV. The mean propagation velocity of plasma is calculated using the transit times of plasma at different distances from the plasma gun and is found to be 4.54 0.25 cm/ s and 1.81 0.18 cm/ s for hydrogen and carbon plasma respectively. The Debye radius is obtained from the measured experimental data that satisfies the thin sheath approximation. The shot-to-shot stability of plasma parameters facilitates the use of plasma guns in laboratory experiments. These types of plasma sources can be used in many applications like plasma opening switches, plasma devices, and as plasma sources.
机构:
Bhabha Atom Res Ctr, Div Laser & Plasma Technol, Mumbai 400085, Maharashtra, IndiaBhabha Atom Res Ctr, Div Laser & Plasma Technol, Mumbai 400085, Maharashtra, India
Singh, S. B.
Chand, N.
论文数: 0引用数: 0
h-index: 0
机构:
Bhabha Atom Res Ctr, Div Laser & Plasma Technol, Mumbai 400085, Maharashtra, IndiaBhabha Atom Res Ctr, Div Laser & Plasma Technol, Mumbai 400085, Maharashtra, India
Chand, N.
Patil, D. S.
论文数: 0引用数: 0
h-index: 0
机构:
Bhabha Atom Res Ctr, Div Laser & Plasma Technol, Mumbai 400085, Maharashtra, IndiaBhabha Atom Res Ctr, Div Laser & Plasma Technol, Mumbai 400085, Maharashtra, India
机构:
Department of Modern Physics,University of Science and Technology of China,Hefei 230026,ChinaDepartment of Modern Physics,University of Science and Technology of China,Hefei 230026,China