Evaluation of Turbulence Index and Flow Pattern for Atherosclerotic Carotid Stenosis: A High-Frame-Rate Vector Flow Imaging Study

被引:1
|
作者
Dong, Yinghui [1 ,2 ,3 ]
Gao, Wenjing [1 ,2 ,3 ]
Hong, Shaofu [1 ,2 ,3 ]
Song, Di [1 ,2 ,3 ]
Liu, Mengmeng [1 ,2 ,3 ]
Du, Yigang [4 ]
Xu, Jinfeng [1 ,2 ,3 ]
Dong, Fajin [1 ,2 ,3 ]
机构
[1] Shenzhen Peoples Hosp, Dept Ultrasound, Shenzhen, Guangdong, Peoples R China
[2] Jinan Univ, Clin Med Coll 2, Shenzhen, Guangdong, Peoples R China
[3] Southern Univ Sci & Technol, Affiliated Hosp 1, Shenzhen, Guangdong, Peoples R China
[4] Shenzhen Mindray Biomed Elect Co Ltd, Shenzhen, Guangdong, Peoples R China
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2024年 / 50卷 / 04期
关键词
Carotid stenosis; Ultrasound; Vector flow imaging; Turbulence; Hemodynamics; ISCHEMIC-STROKE; SHEAR-STRESS; PLAQUE; ARTERY; BIFURCATION; MANAGEMENT; INTENSITY;
D O I
10.1016/j.ultrasmedbio.2023.12.019
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective: The emerging high -frame -rate vector flow imaging provides a new way of hemodynamic evaluation for complex blood flow. This study was aimed at exploring quantitatively the characteristics of complex flow with turbulence (Tur) index and analyzing flow patterns in atherosclerotic internal carotid artery stenosis (ICAS) using high -frame -rate vector flow imaging. Methods: This study prospectively included 60 patients with ICAS. Tur values in different segments of stenosis and cardiac phases were compared. Spearman correlation analysis was performed between clinical plaque characteristics with turbulence grading by ln(Tur). Three complex flow patterns were qualitatively drawn on vector flow mode, and the rates of detection of flow patterns in different stenosis groups and ulceration groups were compared. Results: Highly disordered blood flow was observed in the stenotic (Tur [M, QR] = 12.5%, 21.5%) and distal segment (15.4%, 27.2%), particularly during systole (21.0%, 30.7%, 33.3%, 38.7%, p < 0.05). Spearman correlation analysis revealed that stenosis rate was correlated with turbulence grading in the stenotic (rho = 0.65, p < 0.05) and distal segment (rho = 0.79, p < 0.05), and ulcer formation was correlated with turbulence grading in the stenotic segment (rho = 0.58, p < 0.05). The overall rate of detection of three flow patterns was higher in the severe stenosis group (22/22) versus the mild to moderate stenosis group (21/38) (p < 0.001) and in the ulcer group (21/23) versus the non -ulcer group (23/37) (p < 0.001). Conclusion: High -frame -rate vector flow imaging was helpful in assessing the severity and characteristics of flow turbulence. Lumen geometric factors could affect flow turbulence and blood flow patterns around the plaque. This would provide important hemodynamic information for the detection of high -risk plaque.
引用
收藏
页码:549 / 556
页数:8
相关论文
共 50 条
  • [21] Nanorod-based flow estimation using a high-frame-rate photoacoustic imaging system
    National Taiwan University, Department of Electrical Engineering, Graduate Institute of Biomedical Electronics and Bioinformation, Number 1, Roosevelt Road, Taipei 106, Taiwan
    不详
    J Biomed Opt, 2007, 6
  • [22] HIGH-FRAME-RATE ULTRASOUND COLOR-ENCODED SPECKLE IMAGING OF COMPLEX FLOW DYNAMICS
    Yiu, Billy Y. S.
    Yu, Alfred C. H.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (06): : 1015 - 1025
  • [23] Nanorod-based flow estimation using a high-frame-rate photoacoustic imaging system
    Liao, Chao-Kang
    Huang, Sheng-Wen
    Wei, Chen-Wei
    Li, Pai-Chi
    JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (06)
  • [24] P84: High-Frame Rate Vector Flow Imaging: Relationship Between Carotid Bifurcation Geometry and Flow Patterns
    A. Alfredo Goddi
    L. Luca Aiani
    Y. Yigang Du
    X. Xujin He
    Y. Yingying Shen
    L. Lei Zhu
    Artery Research, 2017, 20 (1) : 76 - 77
  • [25] High-frame-rate color flow imaging with enhanced spatial resolution in virtual real-time
    Guidi, Francesco
    Giangrossi, Claudio
    Dallai, Alessandro
    Ramalli, Alessandro
    Tortoli, Piero
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [26] Real-Time System for High Frame Rate Vector Flow Imaging
    Rossi, S.
    Acerbi, F.
    Dallai, A.
    Guidi, F.
    Meacci, V
    Ramalli, A.
    Tortoli, P.
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [27] High frame rate synthetic aperture vector flow imaging for transthoracic echocardiography
    Villagomez-Hoyos, Carlos A.
    Stuart, Matthias B.
    Bechsgaard, Thor
    Nielsen, Michael Bachmann
    Jensen, Jorgen Arendt
    MEDICAL IMAGING 2016: ULTRASONIC IMAGING AND TOMOGRAPHY, 2016, 9790
  • [28] Carotid artery wall dynamics captured with multi-plane high-frame-rate imaging
    Kruizinga, Pieter
    Mastik, Frits
    Bosch, Johannes G.
    van der Steen, Antonius F. W.
    de Jong, Nico
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [29] CONTRAST-ENHANCED HIGH-FRAME-RATE ULTRASOUND IMAGING OF FLOW PATTERNS IN CARDIAC CHAMBERS AND DEEP VESSELS
    Vos, Hendrik J.
    Voorneveld, Jason D.
    Jebbink, Erik Groot
    Leow, Chee Hau
    Nie, Luzhen
    van den Bosch, Annemien E.
    Tang, Meng-Xing
    Freear, Steven
    Bosch, Johan G.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (11): : 2875 - 2890
  • [30] High Frame Rate Synthetic Aperture 3D Vector Flow Imaging
    Villagomez-Hoyos, Carlos A.
    Holbek, Simon
    Stuart, Matthias Bo
    Jensen, Jorgen Arendt
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,