A New Approach to Implant Stability Using a Flexible Synthetic Silicate-Additive Beta-Tricalcium Phosphate-Poly(D,L-lactide-co-caprolactone) Bone Graft: An In Vitro Study

被引:0
作者
Orhan, Zeynep Dilan [1 ]
Cigerim, Levent [1 ]
机构
[1] Van Yuzuncu Yil Univ, Fac Dent, Dept Oral & Maxillofacial Surg, TR-65090 Van, Turkiye
关键词
bone model; dental implant; implant stability; bone graft; flexible bone graft; INSERTION TORQUE; SCAFFOLDS; SURVIVAL; QUALITY; DENSITY; EROSION;
D O I
10.3390/polym16081101
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The aim of this study was to evaluate the use of a flexible synthetic polymer bone graft to provide implant stability during implant placement in a dense cortical bone model. In the control group (Group 1), sockets were prepared on polyurethane blocks according to the standard implant socket drilling protocol; both oversizing and deepening were applied in Group 2; and only oversizing was applied in Group 3. In Groups 2 and 3, flexible synthetic polymer bone grafts were placed in the sockets prior to implant placement. The implants were placed at the bone level in all groups. The highest torque value obtained was recorded as the insertion torque. In this study, 75 implant sites were included across three groups. The torque values of the implants in the control group were significantly higher than those of the implants with the oversized and deepened sockets and the oversized-only sockets (p < 0.05; p < 0.01). The torque values of the implants with the oversized and deepened sockets were significantly higher than those of the implants with the oversized-only sockets (p < 0.01). In this study, a flexible synthetic polymer bone graft was shown to be effective in achieving implant stability in the management of implants where there has been a loss of primary stability.
引用
收藏
页数:10
相关论文
共 49 条
[1]   The effect of implant placement torque on crestal bone remodeling after I year of loading [J].
Aldahlawi, Salwa ;
Demeter, Angela ;
Irinakis, Tassos .
CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2018, 10 :203-209
[2]   A biomechanical assessment of the relation between the oral implant stability at insertion and subjective bone quality assessment [J].
Alsaadi, Ghada ;
Quirynen, Marc ;
Michiels, Katleen ;
Jacobs, Reinhilde ;
van Steenberghe, Daniel .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2007, 34 (04) :359-366
[3]   Correlation between Insertion Torque and Implant Stability Quotient in Tapered Implants with Knife-Edge Thread Design [J].
Baldi, Domenico ;
Lombardi, Teresa ;
Colombo, Jacopo ;
Cervino, Gabriele ;
Perinetti, Giuseppe ;
Di Lenarda, Roberto ;
Stacchi, Claudio .
BIOMED RESEARCH INTERNATIONAL, 2018, 2018
[4]   The Effect of Insertion Torque on the Clinical Outcome of Single Implants: A Randomized Clinical Trial [J].
Barone, Antonio ;
Alfonsi, Fortunato ;
Derchi, Giacomo ;
Tonelli, Paolo ;
Toti, Paolo ;
Marchionni, Saverio ;
Covani, Ugo .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (03) :588-600
[5]   Implant Compression Necrosis: Current Understanding and Case Report [J].
Bashutski, Jill D. ;
D'Silva, Nisha J. ;
Wang, Hom-Lay .
JOURNAL OF PERIODONTOLOGY, 2009, 80 (04) :700-704
[6]   Pre-Clinical Models in Implant Dentistry: Past, Present, Future [J].
Blanc-Sylvestre, Nicolas ;
Bouchard, Philippe ;
Chaussain, Catherine ;
Bardet, Claire .
BIOMEDICINES, 2021, 9 (11)
[7]  
Coathup MJ, 2011, J BONE JOINT SURG AM, V93A, P2219, DOI [10.2106/JBJS.J.01623, 10.2106/JBJS.I.01623]
[8]   Differences in crestal bone-to-implant contact following an under-drilling compared to an over-drilling protocol. A study in the rabbit tibia [J].
Cohen, Omer ;
Ormianer, Zeev ;
Tal, Haim ;
Rothamel, Daniel ;
Weinreb, Miron ;
Moses, Ofer .
Clinical Oral Investigations, 2016, 20 (09) :2475-2480
[9]   Primary Stability Assessment of Conical Implants in Under-Prepared Sites: An In Vitro Study in Low-Density Polyurethane Foams [J].
Comuzzi, Luca ;
Tumedei, Margherita ;
Covani, Ugo ;
Romasco, Tea ;
Petrini, Morena ;
Montesani, Lorenzo ;
Piattelli, Adriano ;
Di Pietro, Natalia .
APPLIED SCIENCES-BASEL, 2023, 13 (10)
[10]   Primary Stability of Dental Implants in Low-Density (10 and 20 pcf) Polyurethane Foam Blocks: Conical vs Cylindrical Implants [J].
Comuzzi, Luca ;
Tumedei, Margherita ;
Pontes, Ana Emilia ;
Piattelli, Adriano ;
Iezzi, Giovanna .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (08)