Assessment of Sensorized Insoles in Balance and Gait in Individuals With Parkinson's Disease

被引:1
作者
Pergolini, Andrea [1 ]
Bowman, Thomas [2 ]
Lencioni, Tiziana [2 ]
Marzegan, Alberto [2 ]
Meloni, Mario [2 ]
Carrozza, Maria Chiara [1 ,3 ,4 ]
Trigili, Emilio [1 ]
Vitiello, Nicola [1 ,3 ,5 ]
Cattaneo, Davide [2 ,6 ]
Crea, Simona [1 ,3 ,5 ]
机构
[1] Scuola Super Sant Anna, BioRobot Inst, I-56127 Pisa, Italy
[2] IRCCS Fdn Don Carlo Gnocchi Onlus, I-20148 Milan, Italy
[3] Scuola Super Sant Anna, Dept Excellence Robot & AI, I-56127 Pisa, Italy
[4] Natl Res Council Italy CNR, I-00185 Rome, Italy
[5] IRCCS Fdn Don Carlo Gnocchi, I-50143 Florence, Italy
[6] Univ Milan, Dept Pathophysiol & Transplantat, I-20122 Milan, Italy
关键词
Parkinson's Disease; instrumented insoles; plantar pressure; wearable sensors; WEARABLE SENSORS; RELIABILITY; RESISTANCE; VALIDITY; PROTOCOL;
D O I
10.1109/TNSRE.2024.3381537
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Individuals with Parkinson's disease (PD) are characterized by gait and balance disorders limiting their independence and quality of life. Home-based rehabilitation programs, combined with drug therapy, demonstrated to be beneficial in the daily-life activities of PD subjects. Sensorized shoes can extract balance- and gait-related data in home-based scenarios and allow clinicians to monitor subjects' activities. In this study, we verified the capability of a pair of sensorized shoes (including pressure-sensitive insoles and one inertial measurement unit) in assessing ground-level walking and body weight shift exercises. The shoes can potentially be combined with a sensory biofeedback module that provides vibrotactile cues to individuals. Sensorized shoes have been assessed in terms of the capability of detecting relevant gait events (heel strike, flat foot, toe off), estimating spatiotemporal parameters of gait (stance, swing, and double support duration, stride length), estimating gait variables (vertical ground-reaction force, vGRF; coordinate of the center of pressure along the longitudinal axes of the feet, yCoP; and the dorsiflexion angle of the feet, Pitch angle). The assessment compared the outcomes with those extracted from the gold standard equipment, namely force platforms and a motion capture system. Results of this comparison with 9 PD subjects showed an overall median absolute error lower than 0.03 s in detecting the foot-contact, foot-off, and heel-off gait events while performing ground-level walking and lower than 0.15 s in body weight shift exercises. The computation of spatiotemporal parameters of gait showed median errors of 1.62 % of the stance phase duration and 0.002 m of the step length. Regarding the estimation of vGRF, yCoP, and Pitch angle, the median across-subjects Pearson correlation coefficient was 0.90, 0.94, and 0.91, respectively. These results confirm the suitability of the sensorized shoes for quantifying biomechanical features during body weight shift and gait exercises of PD and pave the way to exploit the biofeedback modules of the bidirectional interface in future studies.
引用
收藏
页码:1445 / 1454
页数:10
相关论文
共 43 条
[1]   Parkinson's disease and parkinsonism in a longitudinal study - Two-fold higher incidence in men [J].
Baldereschi, M ;
Di Carlo, A ;
Rocca, WA ;
Vanni, P ;
Maggi, S ;
Perissinotto, E ;
Grigoletto, F ;
Amaducci, L ;
Inzitari, D .
NEUROLOGY, 2000, 55 (09) :1358-1363
[2]   Gait analysis using a shoe-integrated wireless sensor system [J].
Bamberg, Stacy J. Morris ;
Benbasat, Ari Y. ;
Scarborough, Donna Moxley ;
Krebs, David E. ;
Paradiso, Joseph A. .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2008, 12 (04) :413-423
[3]  
Behari M., 2019, Ann. Mov. Disord, V2, P15, DOI [10.4103/AOMD.AOMD1818, DOI 10.4103/AOMD.AOMD1818, DOI 10.4103/AOMD.AOMD_18_18]
[4]   Wearable Devices for Biofeedback Rehabilitation: A Systematic Review and Meta-Analysis to Design Application Rules and Estimate the Effectiveness on Balance and Gait Outcomes in Neurological Diseases [J].
Bowman, Thomas ;
Gervasoni, Elisa ;
Arienti, Chiara ;
Lazzarini, Stefano Giuseppe ;
Negrini, Stefano ;
Crea, Simona ;
Cattaneo, Davide ;
Carrozza, Maria Chiara .
SENSORS, 2021, 21 (10)
[5]   Perception of Time-Discrete Haptic Feedback on the Waist is Invariant With Gait Events [J].
Cesini, I ;
Martini, E. ;
Filosa, M. ;
Spigler, G. ;
Sabatini, A. M. ;
Vitiello, N. ;
Oddo, C. M. ;
Crea, S. .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2020, 28 (07) :1595-1604
[6]   Plantar Pressure-Based Insole Gait Monitoring Techniques for Diseases Monitoring and Analysis: A Review [J].
Chen, Jun-Liang ;
Dai, Yan-Ning ;
Grimaldi, Nicolas S. ;
Lin, Jing-Jing ;
Hu, Bo-Yi ;
Wu, Yin-Feng ;
Gao, Shuo .
ADVANCED MATERIALS TECHNOLOGIES, 2022, 7 (01)
[7]   Recovery from Multiple APAs Delays Gait Initiation in Parkinson's Disease [J].
Cohen, Rajal G. ;
Nutt, John G. ;
Horak, Fay B. .
FRONTIERS IN HUMAN NEUROSCIENCE, 2017, 11
[8]   A Wireless Flexible Sensorized Insole for Gait Analysis [J].
Crea, Simona ;
Donati, Marco ;
De Rossi, Stefano Marco Maria ;
Oddo, Calogero Maria ;
Vitiello, Nicola .
SENSORS, 2014, 14 (01) :1073-1093
[9]  
De Rossi S. M. M., 2013, Patent, Patent No. [2013/027145, 2013027145]
[10]  
Dipaola M, 2017, E-HEALTH BIOENG CONF, P579, DOI 10.1109/EHB.2017.7995490