Continuous blood pressure prediction system using Conv-LSTM network on hybrid latent features of photoplethysmogram (PPG) and electrocardiogram (ECG) signals

被引:4
作者
Kamanditya, Bharindra [1 ]
Fuadah, Yunendah Nur [1 ,4 ]
Mahardika T., Nurul Qashri [1 ]
Lim, Ki Moo [1 ,2 ,3 ]
机构
[1] Kumoh Natl Inst Technol, Dept IT Convergence Engn, Gumi 39177, South Korea
[2] Kumoh Natl Inst Technol, Dept Med IT Convergence Engn, Gumi 39253, South Korea
[3] Meta Heart Inc, Gumi 39253, South Korea
[4] Telkom Univ, Dept Elect Engn, Bandung 40257, Indonesia
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
基金
新加坡国家研究基金会;
关键词
Blood pressure; Photoplethysmography; Electrocardiography; Deep learning; LSTM; PULSE TRANSIT-TIME;
D O I
10.1038/s41598-024-66514-y
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Continuous blood pressure (BP) monitoring is essential for managing cardiovascular disease. However, existing devices often require expert handling, highlighting the need for alternative methods to simplify the process. Researchers have developed various methods using physiological signals to address this issue. Yet, many of these methods either fall short in accuracy according to the BHS, AAMI, and IEEE standards for BP measurement devices or suffer from low computational efficiency due to the complexity of their models. To solve this problem, we developed a BP prediction system that merges extracted features of PPG and ECG from two pulses of both signals using convolutional and LSTM layers, followed by incorporating the R-to-R interval durations as additional features for predicting systolic (SBP) and diastolic (DBP) blood pressure. Our findings indicate that the prediction accuracies for SBP and DBP were 5.306 +/- 7.248 mmHg with a 0.877 correlation coefficient and 3.296 +/- 4.764 mmHg with a 0.918 correlation coefficient, respectively. We found that our proposed model achieved a robust performance on the MIMIC III dataset with a minimum architectural design and high-level accuracy compared to existing methods. Thus, our method not only meets the passing category for BHS, AAMI, and IEEE guidelines but also stands out as the most rapidly accurate deep-learning-based BP measurement device currently available.
引用
收藏
页数:11
相关论文
共 4 条
  • [1] Repetitive neural network (RNN) based blood pressure estimation using PPG and ECG signals
    Senturk, Umit
    Yucedag, Ibrahim
    Polat, Kemal
    2018 2ND INTERNATIONAL SYMPOSIUM ON MULTIDISCIPLINARY STUDIES AND INNOVATIVE TECHNOLOGIES (ISMSIT), 2018, : 188 - 191
  • [2] NABNet: A Nested Attention-guided BiConvLSTM network for a robust prediction of Blood Pressure components from reconstructed Arterial Blood Pressure waveforms using PPG and ECG signals
    Mahmud, Sakib
    Ibtehaz, Nabil
    Khandakar, Amith
    Rahman, M. Sohel
    Gonzales, Antonio JR.
    Rahman, Tawsifur
    Hossain, Md Shafayet
    Hossain, Md. Sakib Abrar
    Faisal, Md. Ahasan Atick
    Abir, Farhan Fuad
    Musharavati, Farayi
    Chowdhury, Muhammad E. H.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 79
  • [3] Cuff-Less Blood Pressure Prediction from ECG and PPG Signals Using Fourier Transformation and Amplitude Randomization Preprocessing for Context Aggregation Network Training
    Treebupachatsakul, Treesukon
    Boosamalee, Apivitch
    Shinnakerdchoke, Siratchakrit
    Pechprasarn, Suejit
    Thongpance, Nuntachai
    BIOSENSORS-BASEL, 2022, 12 (03):
  • [4] Continuous blood pressure monitoring using photoplethysmography and electrocardiogram signals by random forest feature selection and GWO-GBRT prediction model
    Liu, Shimin
    Huang, Zhiwen
    Zhu, Jianmin
    Liu, Baolin
    Zhou, Panyu
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2024, 88