How medical device instructions for use engage users

被引:2
作者
Cherne N. [1 ]
Moses R. [2 ]
Piperato S.M. [1 ]
Cheung C. [1 ]
机构
[1] Core Human Factors, Inc., Bala Cynwyd, PA
[2] Core Human Factors, Ltd., Netanya
关键词
Testing - Surveys - Risk assessment;
D O I
10.2345/0899-8205-54.4.258
中图分类号
X9 [安全科学];
学科分类号
0837 ;
摘要
Instructions for use (IFUs) often are used as risk control measures for medical devices with the potential to expose users or others to use-related hazards and hazardous situations that are not entirely mitigated by device design. In the authors’ extensive experience observing representative users interact with medical devices in simulated-use studies, individuals’ engagement with medical device IFUs varies widely. This variance raises questions regarding how various user groups use IFUs and the factors that make an IFU stronger or weaker for its intended users, uses, and use environments. An online survey was conducted to examine (1) first-time use of medical device IFUs, (2) how first-time use strategies vary across typical user groups for medical devices (e.g., patients, lay caregivers, and healthcare professionals), and (3) which design elements promote initial engagement with IFUs. The results showed that IFUs are used in a variety of ways, including as preparation before use, as guides during use, and as troubleshooting resources during use, as well as that IFUs are not used at all. Overall, the user groups tested responded similarly across all of the survey questions. Bullet point organization, figures, and logical flow were reported to be the most engaging design elements. Small font size and poor organization and flow were reported to be the least engaging design elements. IFU designers can use various usability testing methods to assess their assumptions regarding how a product’s users will use the IFU and to make the IFU more engaging. © Copyright AAMI 2020.
引用
收藏
页码:258 / 268
页数:10
相关论文
共 9 条
[1]  
Guideline on the Readability of the Labelling and Package Leaflet of Medicinal Products for Human Use, (2009)
[2]  
Medical devices—Part 1: Application of usability engineering to medical devices
[3]  
Medical devices—Part 2: Guidance on the application of usability engineering to medical devices, (2016)
[4]  
Applying Human Factors and Usability Engineering to Medical Devices: Guidance for Industry and Food and Drug Administration Staff
[5]  
Mayberry JF., The design and application of effective written instructional material: a review of published work, Postgrad Med J, 83, 983, pp. 596-598, (2007)
[6]  
Guidance on Medical Device Patient Labeling: Final Guidance for Industry and FDA Reviewers
[7]  
Backinger CL., Kingsley PA., Write it Right: Recommendations for Developing User Instruction Manuals for Medical Devices Used in Home Health Care, (1993)
[8]  
Instructions for Use—Patient Labeling for Human Prescription Drug and Biological Products and Drug-Device and Biologic-Device Combination Products—Content and Format: Guidance for Industry
[9]  
Egeth M, Fink N, Soosaar J, Et al., If you can read this, you’re too close: human factors in human factors standards for font sizes, Human Factors and Ergonomics Society: International Symposium on Human Factors and Ergonomics in Health Care: Leading the Way, (2014)