Phase-separation adaptive autoreclosing strategy for ground faults on double-circuit transmission lines with shunt reactors

被引:0
|
作者
Jiang, Jiangbo [1 ]
Xie, Chao [1 ]
Li, Fengting [1 ]
Yin, Chunya [1 ]
Zhang, Gaohang [1 ]
机构
[1] College of Electrical Engineering, Xinjiang University, Urumqi,830017, China
关键词
27;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:12 / 24
相关论文
共 50 条
  • [1] Adaptive autoreclosing scheme for line-to-line grounded faults on double-circuit transmission lines with shunt reactors
    Zhou W.
    Li F.
    Xie C.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2022, 50 (01): : 33 - 41
  • [2] Adaptive Autoreclosing Scheme for Line-to-Line Nongrounded Faults on Double-Circuit Transmission Lines Based on Phase-to-Phase Reactive Power
    Zhou, Weiji
    Li, Fengting
    Xie, Chao
    Wang, Bin
    Gong, Lijiao
    Yang, Shanglin
    IEEE ACCESS, 2020, 8 : 144092 - 144104
  • [3] An Adaptive Reclosing Scheme for Cross-Line Faults on Double-Circuit Wind Power Outgoing Lines with Shunt Reactors
    Hu, Sen
    Xie, Chao
    Yin, Chunya
    ENERGIES, 2024, 17 (06)
  • [4] Identification of permanent faults for three-phase autoreclosing using inductance parameter on transmission lines with shunt reactors
    Qiao, Zhanjun
    Fan, Wenbo
    International Journal of Smart Home, 2013, 7 (05): : 197 - 206
  • [5] Permanent faults identification based on mode component for three-phase autoreclosing on transmission lines with shunt reactors
    Suonan, Jiale
    Liang, Zhenfeng
    Song, Guobing
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (25): : 81 - 86
  • [6] A New Algorithm for Faults on Double-Circuit Lines in Phase Coordinates
    Wang, Anning
    Chen, Qing
    2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 3517 - 3522
  • [7] Adaptive distance protection of double-circuit lines for faults involving earth
    Izykowski, Jan
    Bozek, Marcin
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (9A): : 22 - 26
  • [8] An improved phase component method for calculating faults on the double-circuit transmission lines on same tower
    Wang, Anning
    Chen, Qing
    Zhou, Zhanping
    Tang, Shaowei
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2009, 33 (13): : 58 - 62
  • [9] Adaptive distance protection scheme for high resistance phase to phase faults on double-circuit transmission line
    Ciprian, Borascu Ionut
    Iliescu, Sergiu Stelian
    2015 20TH INTERNATIONAL CONFERENCE ON CONTROL SYSTEMS AND COMPUTER SCIENCE, 2015, : 972 - 977
  • [10] Fault Resistance Investigations for Faults in Double-Circuit Double-Fed Transmission Lines
    Abdel-Fattah, Mohamed F.
    El-Alaily, Asem A.
    El-Razaz, Zaghlol S.
    2016 17TH INTERNATIONAL SCIENTIFIC CONFERENCE ON ELECTRIC POWER ENGINEERING (EPE), 2016, : 142 - 147