A Design of Online Fault Diagnosis System Based on ESR for Electrolytic Capacitors

被引:0
作者
An Z. [1 ]
Zhang G. [1 ]
Li K. [2 ]
Wu X. [1 ]
Cheng S. [2 ]
Qiao H. [3 ]
机构
[1] School of Automation, Central South University, Changsha
[2] School of Traffic & Transportation Engineering, Central South University, Changsha
[3] Unique Railway Transport Technology Co., Ltd, Changchun
来源
Xibei Gongye Daxue Xuebao/Journal of Northwestern Polytechnical University | 2019年 / 37卷 / 03期
关键词
Electrolytic capacitor; Equivalent series resistance(ESR); Fault diagnosis; Online;
D O I
10.1051/jnwpu/20193730594
中图分类号
学科分类号
摘要
ESR(Equivalent Series Resistance) is one of the important indicators for evaluating health status of electrolytic capacitors. Due to the structural specificity of the electrolytic capacitors, ESR is difficult to measure directly. In order to monitor the health status of the electrolytic capacitor in real time, an equivalent model for the electrolytic capacitor is established. The ESR frequency characteristics and temperature characteristics are analyzed and tested. The method of online fault diagnosis by evaluating the health status of the electrolytic capacitor with online calculation of ESR is proposed. Comparing the calculated value of ESR real-time with the initial value, when the former increases to a certain threshold value with respect to the latter under the same working condition, the electrolytic capacitor can be considered as failed, and the observer can perform replacement processing according to this mechanism in time. Finally, the effectiveness of the method was verified by using the dSPACE semi-physical experimental platform. © 2019 Journal of Northwestern Polytechnical University.
引用
收藏
页码:594 / 600
页数:6
相关论文
共 23 条
[1]  
Ren L., Fault Feature Extraction Techniques for Power Devices in Power Electronic Converters: a Review, Proceedings of the CSEE, 35, 12, pp. 3089-3101, (2015)
[2]  
Pang H.M., Bryan P.M.H., A Life Prediction Scheme for Electrolytic Capacitors in Power Converters without Current Sensor, Applied Power Electronics Conference and Exposition, pp. 973-979, (2010)
[3]  
Kai Y., Tang W., Xiaopeng B.I., Et al., An Online Monitoring Scheme of DC-Link Capacitor's ESR and C for a Boost PFC Converter, IEEE Trans on Power Electronics, 31, 8, pp. 5944-5951, (2016)
[4]  
Pu X.S., Nguyen T.H., Lee D.C., Et al., Fault Diagnosis of DC-Link Capacitors in Three-Phase AC/DC PWM Converters by Online Estimation of Equivalent Series Resistance, IEEE Trans on Industrial Electronics, 60, 9, pp. 4118-4127, (2013)
[5]  
Amaral A.M.R., Cardoso A.J.M., Using Newton-Raphson Method to Estimate the Condition of Aluminum Electrolytic Capacitors, IEEE International Symposium on Industrial Electronics, pp. 827-832, (2007)
[6]  
Tsang K.M., Chan W.L., Simple Method for Measuring the Equivalent Series Inductance and Resistance of Electrolytic Capacitors, IET Power Electronics, 3, 4, (2010)
[7]  
Amaral A.M.R., Cardoso A.J.M., A Simple Offline Technique for Evaluating the Condition of Aluminum Electrolytic Capacitors, IEEE Trans on Industrial Electronics, 56, 8, pp. 3230-3237, (2009)
[8]  
Amaral A.M.R., Cardoso A.J.M., An Automatic Technique to Obtain the Equivalent Circuit of Aluminum Electrolytic Capacitors, Conference of the IEEE Industrial Electronics Society, (2008)
[9]  
Abdennadher K., Venet P., Rojat G., Et al., A Real-Time Predictive-Maintenance System of Aluminum Electrolytic Capacitors Used in Uninterrupted Power Supplies, IEEE Trans on Industry Applications, 46, 4, pp. 1644-1652, (2010)
[10]  
Gasperi M.L., Life Prediction Modeling of Bus Capacitors in AC Variable-Frequency Drives, IEEE Trans on Industry Applications, 41, 6, pp. 1430-1435, (2005)