Glucose Targets Using Continuous Glucose Monitoring Metrics in Older Adults With Diabetes: Are We There Yet?

被引:5
作者
Toschi, Elena [1 ]
O'Neal, David [2 ,3 ,4 ]
Munshi, Medha [1 ]
Jenkins, Alicia [2 ,3 ,4 ,5 ,6 ]
机构
[1] Harvard Med Sch, Joslin Diabet Ctr, One Joslin Pl, Boston, MA 02215 USA
[2] Univ Melbourne, St Vincents Hosp, Dept Med, Melbourne, Vic, Australia
[3] St Vincents Hosp, Dept Diabet & Endocrinol, Melbourne, Vic, Australia
[4] Univ Melbourne, Australian Ctr Accelerating Diabet Innovat, Melbourne, Vic, Australia
[5] Baker Heart & Diabet Inst, Melbourne, Vic, Australia
[6] Monash Univ, Fac Med, Melbourne, Vic, Australia
关键词
diabetes mellitus; older adults; continuous glucose monitoring (CGM); hypoglycemia; technology; GLYCEMIC CONTROL; SEVERE HYPOGLYCEMIA; ELDERLY-PATIENTS; TYPE-1; RISK; HYPERGLYCEMIA; FRAILTY; IMPACT; HBA1C;
D O I
10.1177/19322968241247568
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The older population is increasing worldwide and up to 30% of older adults have diabetes. Older adults with diabetes are at risk of glucose-related acute and chronic complications. Recently, mostly in type 1 diabetes (T1D), continuous glucose monitoring (CGM) devices have proven beneficial in improving time in range (TIR glucose, 70-180 mg/dL or glucose 3.9-10 mmol/L), glycated hemoglobin (HbA1c), and in lowering hypoglycemia (time below range [TBR] glucose <70 mg/dL or glucose <3.9 mmol/L). The international consensus group formulated CGM glycemic targets relating to older adults with diabetes based on very limited data. Their recommendations, based on expert opinion, were aimed at mitigating hypoglycemia in all older adults. However, older adults with diabetes are a heterogeneous group, ranging from healthy to very complex frail individuals based on chronological, biological, and functional aging. Recent clinical trial and real-world data, mostly from healthy older adults with T1D, demonstrated that older adults often achieve CGM targets, including TIR recommended for non-vulnerable groups, but less often meet the recommended TBR <1%. Existing data also support that hypoglycemia avoidance may be more strongly related to minimization of glucose variability (coefficient of variation [CV]) rather than lower TIR. Very limited data are available for glucose goals in older adults adjusted for the complexity of their health status. Herein, we review the bidirectional associations between glucose and health status in older adults with diabetes; use of diabetes technologies, and their impact on glucose control; discuss current guidelines; and propose a new set of CGM targets for older adults with insulin-treated diabetes that are individualized for health and living status.
引用
收藏
页码:800 / 807
页数:8
相关论文
共 50 条
[41]   Continuous glucose monitoring in type 1 diabetes [J].
Mauras, Nelly ;
Fox, Larry ;
Englert, Kimberly ;
Beck, Roy W. .
ENDOCRINE, 2013, 43 (01) :41-50
[42]   Continuous Glucose Monitoring Metrics: Interpretation and Integrations [J].
Goldman, Jennifer .
AMERICAN JOURNAL OF MANAGED CARE, 2022, 28 (04) :S69-S75
[43]   Relationships of hypoglycemia awareness, hypoglycemia beliefs, and continuous glucose monitoring glycemic profiles with anxiety and depression symptoms in adults with type 1 diabetes using continuous glucose monitoring systems [J].
Lin, Yu Kuei ;
Hepworth, Emily ;
de Zoysa, Nicole ;
Mccurley, Jessica ;
Vajravelu, Mary Ellen ;
Ye, Wen ;
Piatt, Gretchen A. ;
Amiel, Stephanie A. ;
Fisher, Simon J. ;
Pop-Busui, Rodica ;
Aikens, James E. .
DIABETES RESEARCH AND CLINICAL PRACTICE, 2024, 209
[44]   Essential Continuous Glucose Monitoring Metrics: The Principal Dimensions of Glycemic Control in Diabetes [J].
Montaser, Eslam ;
Fabris, Chiara ;
Kovatchev, Boris .
DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (11) :797-804
[45]   Evaluation of Reference Metrics for Continuous Glucose Monitoring in Persons Without Diabetes and Prediabetes [J].
Sofizadeh, Sheyda ;
Pehrsson, Anders ;
Olafsdottir, Arndis F. ;
Lind, Marcus .
JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (02) :373-382
[46]   Evaluating the Impact of Continuous Glucose Monitoring on Erectile Dysfunction in Type 1 Diabetes: A Focus on Reducing Glucose Variability and Inflammation [J].
Tecce, Nicola ;
Menafra, Davide ;
Progano, Mattia ;
Tecce, Mario Felice ;
Pivonello, Rosario ;
Colao, Annamaria .
HEALTHCARE, 2024, 12 (18)
[47]   Detection of asymptomatic drug-induced hypoglycemia using continuous glucose monitoring in older people - Systematic review [J].
Mattishent, K. ;
Loke, Y. K. .
JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2018, 32 (08) :805-812
[48]   The effects of aging and frailty on inpatient glycemic control by continuous glucose monitoring in patients with type 2 diabetes [J].
Idrees, T. ;
Zabala, Z. E. ;
Moreno, E. M. ;
Gerges, A. ;
Urrutia, M. A. ;
Ruiz, J. G. ;
Vaughan, C. ;
Vellanki, P. ;
Pasquel, F. J. ;
Peng, L. ;
Umpierrez, G. E. .
DIABETES RESEARCH AND CLINICAL PRACTICE, 2023, 198
[49]   Continuous glucose monitoring with data sharing in older adults: A qualitative study [J].
Allen, Nancy A. ;
Grigorian, Ernest G. ;
Mansfield, Kelly ;
Berg, Cynthia A. ;
Litchman, Michelle L. .
JOURNAL OF CLINICAL NURSING, 2023, 32 (19-20) :7483-7494
[50]   Continuous glucose monitoring in persons with type 2 diabetes not using insulin [J].
Cowart, Kevin ;
Updike, Wendy H. ;
Franks, Rachel .
EXPERT REVIEW OF MEDICAL DEVICES, 2021, 18 (11) :1049-1055