How do imaging protocols affect the assessment of root-end fillings?

被引:3
作者
Esteves Torres, Fernanda Ferrari [1 ]
Jacobs, Reinhilde [2 ,3 ,4 ]
EzEldeen, Mostafa [2 ,3 ]
de Faria-Vasconcelos, Karla [2 ,3 ]
Guerreiro-Tanomaru, Juliane Maria [1 ]
dos Santos, Bernardo Camargo [5 ]
Tanomaru-Filho, Mario [1 ]
机构
[1] Sao Paulo State Univ UNESP, Sch Dent, Dept Restorat Dent, Rua Humaita 1680, BR-14801903 Araraquara, SP, Brazil
[2] Katholieke Univ Leuven, Fac Med, Dept Imaging & Pathol, OMFS IMPATH Res Grp, Leuven, Belgium
[3] Univ Hosp Leuven, Oral & Maxillofacial Surg, Leuven, Belgium
[4] Karolinska Inst, Dept Dent Med, Stockholm, Sweden
[5] Fed Univ Rio de Janeiro UFRJ, Dept Nucl Energy, Rio De Janeiro, RJ, Brazil
关键词
Dental materials; Endodontics; Methods; X-ray microtomography; BEAM COMPUTED-TOMOGRAPHY; MICRO-CT ANALYSIS; CALCIUM SILICATE; VOXEL SIZE; BONE; PARAMETERS; CEMENTS; MTA; ADAPTATION; INTERFACE;
D O I
10.5395/rde.2022.47.e2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study investigated the impact of micro-computed tomography (micro-CT)-based voxel size on the analysis of material/dentin interface voids and thickness of different endodontic cements. Materials and Methods: Following root-end resection and apical preparation, maxillary premolars were filled with mineral trioxide aggregate (MTA), Biodentine, and intermediate restorative material (IRM) (n = 24). The samples were scanned using micro- CT (SkyScan 1272; Bruker) and the cement/dentin interface and thickness of materials were evaluated at voxel sizes of 5, 10, and 20 mu m. Analysis of variance and the Tukey test were conducted, and the degree of agreement between different voxel sizes was evaluated using the Bland and Altman method (p < 0.05). Results: All materials showed an increase in thickness from 5 to 10 and 20 mu m (p < 0.05). When evaluating the interface voids, materials were similar at 5 mu m (p > 0.05), while at 10 and 20 mu m Biodentine showed the lowest percentage of voids (p < 0.05). A decrease in the interface voids was observed for MTA and IRM at 20 mu m, while Biodentine showed differences among all voxel sizes (p < 0.05). The Bland-Altman plots for comparisons among voxel sizes showed the largest deviations when comparing images between 5 and 20 mu m. Conclusions: Voxel size had an impact on the micro-CT evaluation of thickness and interface voids of endodontic materials. All cements exhibited an increase in thickness and a decrease in the void percentage as the voxel size increased, especially when evaluating images at 20 mu m.
引用
收藏
页数:11
相关论文
共 36 条
[1]   Effect of ultrasonic activation on dentinal tubule penetration of calcium silicate-based cements [J].
Aksel, Hacer ;
Arslan, Elifcan ;
Purali, Nuhan ;
Uyanik, Ozgur ;
Nagas, Emre .
MICROSCOPY RESEARCH AND TECHNIQUE, 2019, 82 (05) :624-629
[2]   Chemical modification of ProRoot MTA to improve handling characteristics and decrease setting time [J].
Ber, Benjamin S. ;
Hatton, John F. ;
Stewart, Gregory P. .
JOURNAL OF ENDODONTICS, 2007, 33 (10) :1231-1234
[3]   Marginal Gaps between 2 Calcium Silicate and Glass lonomer Cements and Apical Root Dentin [J].
Biocanin, Vladimir ;
Antonijevic, Djordje ;
Postic, Srdan ;
Ilic, Dragan ;
Vukovic, Zorica ;
Milic, Marija ;
Fan, Yifang ;
Li, Zhiyu ;
Brkovic, Bozidar ;
Duric, Marija .
JOURNAL OF ENDODONTICS, 2018, 44 (05) :816-821
[4]   A validated methodology for patient specific computational modeling of self-expandable transcatheter aortic valve implantation [J].
Bosmans, Bart ;
Famaey, Nele ;
Verhoelst, Eva ;
Bosmans, Johan ;
Vander Sloten, Jos .
JOURNAL OF BIOMECHANICS, 2016, 49 (13) :2824-2830
[5]   Guidelines for Assessment of Bone Microstructure in Rodents Using Micro-Computed Tomography [J].
Bouxsein, Mary L. ;
Boyd, Stephen K. ;
Christiansen, Blaine A. ;
Guldberg, Robert E. ;
Jepsen, Karl J. ;
Mueller, Ralph .
JOURNAL OF BONE AND MINERAL RESEARCH, 2010, 25 (07) :1468-1486
[6]   Investigation of the hydration and bioactivity of radiopacified tricalcium silicate cement, Biodentine and MTA Angelus [J].
Camilleri, Josette ;
Sorrentino, Francois ;
Damidot, Denis .
DENTAL MATERIALS, 2013, 29 (05) :580-593
[7]   Spiral scanning imaging and quantitative calculation of the 3-dimensional screw-shaped bone-implant interface on micro-computed tomography [J].
Choi, Jung-Yoo Chesaria ;
Choi, Cham Albert ;
Yeo, In-Sung Luke .
JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2018, 48 (04) :202-212
[8]   Effect of voxel size on 3D micro-CT analysis of cortical bone porosity [J].
Cooper, David ;
Turinsky, Andrei ;
Sensen, Christoph ;
Hallgrimsson, Benedikt .
CALCIFIED TISSUE INTERNATIONAL, 2007, 80 (03) :211-219
[9]   Is there correlation between polymerization shrinkage, gap formation, and void in bulk fill composites? A μCT study [J].
dos Santos Almeida Junior, Lauber Jose ;
de Souza Penha, Karla Janilee ;
Souza, Ana Ferreira ;
Oliveira Lula, Estevam Carlos ;
Magalhaes, Fernando Cintra ;
Lima, Darlon Martins ;
Firoozmand, Leily Macedo .
BRAZILIAN ORAL RESEARCH, 2017, 31 :1-10
[10]   Obturation quality of calcium silicate-based cements placed with different techniques in teeth with perforating internal root resorption: a micro-computed tomographic study [J].
Eren, Selen Kucukkaya ;
Aksel, Hacer ;
Ors, Sevinc Askerbeyli ;
Serper, Ahmet ;
Kocak, Yaprak ;
Ocak, Mert ;
Celik, Hakan Hamdi .
CLINICAL ORAL INVESTIGATIONS, 2019, 23 (02) :805-811