A double-ended third harmonic method for vegetation high impedance fault location in overhead distribution systems

被引:1
|
作者
Gallas, Mairon [1 ]
Farias, Patrick Escalante [2 ]
Wontroba, Aldair [3 ]
Morais, Adriano Peres [3 ]
Vieira, Joa Paulo Abreu [4 ]
Rossini, Jean Pereira [3 ]
Junior, Ghendy Cardoso [3 ]
机构
[1] Fed Univ Santa Maria UFSM, Ctr Excelencia Energia & Sistemas Potencia CEESP, Lab Analise & Protecao Sistemas Eletr LAPES, Programa Posgrad Energia Elect PPGEE, Santa Maria, RS, Brazil
[2] Fed Inst Rio Grande Do Sul IFRS, Farroupilha, RS, Brazil
[3] Univ Fed Santa Maria, PPGEE, CEESP, LAPES, Santa Maria, RS, Brazil
[4] Fed Univ Para UFPA, Belem, PA, Brazil
关键词
Fault location; Vegetation high -impedance fault; Third harmonic analysis; Overhead distribution systems; DISTANCE PROTECTION; ARCING FAULT; ALGORITHM;
D O I
10.1016/j.epsr.2024.110257
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Vegetation-related high-impedance faults (VHIFs) on overhead distribution systems can cause damage, maintenance issues, and even wildfires, impacting both utilities and ecosystems. Existing fault location techniques struggle to accurately locate VHIFs. In this paper, we propose a novel double-ended terminal location method based on the third harmonic component of the fault system. The proposed technique determines the distance of the VHIF by approximating the third harmonic voltage at the fault local, utilizing measurements from the remote terminal located at the far-end of the feeder. This method efficiently locates VHIFs with just two measurement terminals, cutting the need and cost of extensive sensor deployment. Moreover, the proposed method overcomes the limitations of traditional fault location techniques by using a third harmonic model of the faulted system, eliminating the need for complex mathematical models to approximate the fault behavior and voltage at the fault local. Simulation tests were conducted to validate the proposed method, demonstrating its effectiveness in accurately locating VHIFs. The technique achieved error rates below 1.6 %, making it a promising solution for real-world applications in power distribution systems. The ability to precisely locate VHIFs meets a proactive protection philosophy and contributes to improved power system protection and ensures uninterrupted power supply.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Third harmonic potential distribution based stator ground fault accurate location method for large generators
    Li, Wei
    Qiao, Jian
    Wang, Yikai
    Liu, Ren
    Lv, Tao
    Yin, Xianggen
    Liu, Feng
    ENERGY REPORTS, 2022, 8 : 21 - 28
  • [32] HIGH IMPEDANCE FAULT DETECTION USING THIRD HARMONIC CURRENT.
    Lee, I.
    Electric Power Research Institute, (Report) EPRI EL, 1982,
  • [33] Third harmonic potential distribution based stator ground fault accurate location method for large generators
    Li, Wei
    Qiao, Jian
    Wang, Yikai
    Liu, Ren
    Lv, Tao
    Yin, Xianggen
    Liu, Feng
    Energy Reports, 2022,
  • [34] Generalized Impedance-Based Fault Location for Distribution Systems
    Krishnathevar, Ramar
    Eng Eng Ngu
    IEEE TRANSACTIONS ON POWER DELIVERY, 2012, 27 (01) : 449 - 451
  • [35] DOUBLE-ENDED HYDROGEN THYRATRONS FOR CROWBAR PROTECTION OF HIGH-POWER TWT SYSTEMS
    NICHOLLS, NS
    MENOWN, H
    WHELDON, RJ
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1979, 26 (10) : 1456 - 1461
  • [36] A New Fault-Location Method with High Robustness for Distribution Systems
    You, Dahai
    Ye, Lei
    Yin, Xianggen
    Yao, Qiguo
    Wang, Ke
    Wu, Junchun
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2013, 19 (06) : 31 - 36
  • [37] A novel fault location scheme for multi-terminal transmission lines based on principle of double-ended traveling wave
    Fan, Xinqiao
    Zhu, Yongli
    Dianwang Jishu/Power System Technology, 2013, 37 (01): : 261 - 269
  • [38] High impedance fault detection on distribution systems
    Wester, CG
    1998 RURAL ELECTRIC POWER CONFERENCE, 1998, : C51 - C55
  • [39] High Impedance Fault Detection and Location in Combined Overhead Line and Underground Cable Distribution Networks Equipped with Data Loggers
    Khavari, Saeid
    Dashti, Rahman
    Shaker, Hamid Reza
    Santos, Athila
    ENERGIES, 2020, 13 (09)
  • [40] A data-driven impedance estimation and matching method for high impedance fault detection and location of distribution networks
    Zhang, Zhenyu
    Li, Yong
    Wang, Zhiyu
    Liu, Junle
    Chen, An
    Cao, Yijia
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2025, 165