A double-ended third harmonic method for vegetation high impedance fault location in overhead distribution systems

被引:1
|
作者
Gallas, Mairon [1 ]
Farias, Patrick Escalante [2 ]
Wontroba, Aldair [3 ]
Morais, Adriano Peres [3 ]
Vieira, Joa Paulo Abreu [4 ]
Rossini, Jean Pereira [3 ]
Junior, Ghendy Cardoso [3 ]
机构
[1] Fed Univ Santa Maria UFSM, Ctr Excelencia Energia & Sistemas Potencia CEESP, Lab Analise & Protecao Sistemas Eletr LAPES, Programa Posgrad Energia Elect PPGEE, Santa Maria, RS, Brazil
[2] Fed Inst Rio Grande Do Sul IFRS, Farroupilha, RS, Brazil
[3] Univ Fed Santa Maria, PPGEE, CEESP, LAPES, Santa Maria, RS, Brazil
[4] Fed Univ Para UFPA, Belem, PA, Brazil
关键词
Fault location; Vegetation high -impedance fault; Third harmonic analysis; Overhead distribution systems; DISTANCE PROTECTION; ARCING FAULT; ALGORITHM;
D O I
10.1016/j.epsr.2024.110257
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Vegetation-related high-impedance faults (VHIFs) on overhead distribution systems can cause damage, maintenance issues, and even wildfires, impacting both utilities and ecosystems. Existing fault location techniques struggle to accurately locate VHIFs. In this paper, we propose a novel double-ended terminal location method based on the third harmonic component of the fault system. The proposed technique determines the distance of the VHIF by approximating the third harmonic voltage at the fault local, utilizing measurements from the remote terminal located at the far-end of the feeder. This method efficiently locates VHIFs with just two measurement terminals, cutting the need and cost of extensive sensor deployment. Moreover, the proposed method overcomes the limitations of traditional fault location techniques by using a third harmonic model of the faulted system, eliminating the need for complex mathematical models to approximate the fault behavior and voltage at the fault local. Simulation tests were conducted to validate the proposed method, demonstrating its effectiveness in accurately locating VHIFs. The technique achieved error rates below 1.6 %, making it a promising solution for real-world applications in power distribution systems. The ability to precisely locate VHIFs meets a proactive protection philosophy and contributes to improved power system protection and ensures uninterrupted power supply.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Frequency domain double-ended method of fault location for transmission lines
    Faybisovich, V.
    Khoroshev, M. I.
    2008 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, 2008, : 941 - +
  • [2] An investigation into the robustness of a double-ended wideband impedance-based fault location technique
    Hayder K. Jahanger
    David W. P. Thomas
    Mark Sumner
    Scientific Reports, 13
  • [3] An investigation into the robustness of a double-ended wideband impedance-based fault location technique
    Jahanger, Hayder K.
    Thomas, David W. P.
    Sumner, Mark
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [4] A novel method of high impedance fault detection and fault resistance calculation based on damping rate double-ended measurement for distribution network
    Yu, Kun
    Yu, Quan
    Zeng, Xiangjun
    Zeng, Jupeng
    Ni, Yanru
    Zou, Hao
    Liu, Feng
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 136
  • [5] Impact of an inverter-based DG on a double-ended fault location method
    Jahanger, Hayder K.
    Thomas, David W. P.
    Sumner, Mark
    Rose, Christopher
    JOURNAL OF ENGINEERING-JOE, 2018, (15): : 1078 - 1083
  • [6] A New Double-Ended Fault-Location Scheme for Utilization in Integrated Power Systems
    Jia, Ke
    Thomas, David W. P.
    Sumner, Mark
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (02) : 594 - 603
  • [7] High impedance fault detection in mutually coupled double-ended transmission lines using high frequency disturbances
    Aboul-Zahab, Essam M.
    Eldin, El Sayed Tag
    Ibrahim, Doaa Khalil
    Saleh, Saber Mohamed
    2008 12TH INTERNATIONAL MIDDLE EAST POWER SYSTEM CONFERENCE, VOLS 1 AND 2, 2008, : 378 - 385
  • [8] Fault location for aircraft distribution systems using harmonic impedance estimation
    Zhou, Q.
    Sumner, M.
    Thomas, D.
    IET ELECTRICAL SYSTEMS IN TRANSPORTATION, 2012, 2 (03) : 119 - 129
  • [9] Novel Fault-Location Method for Overhead Electrical Distribution Systems
    Alwash, Shamam Fadhil
    Ramachandaramurthy, Vigna Kumaran
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2013, 8 : S13 - S19
  • [10] SIMPLIFIED ANALYSIS OF TRANSIENT DUE TO FAULT INITIATION ON DOUBLE-ENDED OVERHEAD AND UNDERGROUND TRANSMISSION-LINES
    MATSUURA, K
    KINOSHITA, H
    IEE PROCEEDINGS-C GENERATION TRANSMISSION AND DISTRIBUTION, 1983, 130 (02) : 75 - 82