Zirconia dental implants; the relationship between design and clinical outcome: A systematic review

被引:5
|
作者
Gul, Abdulaziz [1 ,2 ,6 ]
Papia, Evaggelia [1 ]
Naimi-Akbar, Aron [3 ,4 ]
Ruud, Amund [5 ]
von Steyern, Per Vult
机构
[1] Malmo Univ, Fac Odontol, Dept Mat Sci & Technol, Div 2, Malmo, Sweden
[2] Umm Al Qura Univ, Fac Dent Med, Dept Oral & Maxillofacial Surg, Mecca, Saudi Arabia
[3] Malmo Univ, Fac Odontol, Hlth Technol Assessment Odontol HTA O, Malmo, Sweden
[4] Malmo Univ, Fac Odontol, Dept Oral & Maxillofacial Surg & Oral Med, Div 2, Malmo, Sweden
[5] Nord Inst Dent Mat NIOM, Oslo, Norway
[6] Umm Al Qura Univ, Fac Dent Med, Dept Oral & Maxillofacial Surg, Mecca 24381, Saudi Arabia
关键词
Ceramics; Clinical outcome; Dental implant; Implant design; Implant diameter; Implant surface; SINGLE-TOOTH REPLACEMENT; ORAL IMPLANTS; PROSPECTIVE COHORT; IMMEDIATE OCCLUSAL; TISSUE-RESPONSE; TITANIUM; SUCCESS; SURVIVAL; OSSEOINTEGRATION; RESTORATION;
D O I
10.1016/j.jdent.2024.104903
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To evaluate the clinical outcome of different designs of zirconia dental implants. Data: This systematic review adhered to the PRISMA checklist and followed the PICO framework. The protocol is registered in PROSPERO (CRD42022337228). Sources: The search was conducted in March 2023 through four databases (PubMed, Web of Science, Cochrane Library, and Google Scholar) along with a search of references in the related reviews. Three authors reviewed on title, and abstract level and analysed the risk of bias, and all authors reviewed on a full-text level. Study selection: Clinical studies excluding case reports for patients treated with different designs of zirconia dental implants were included. From a total of 2728 titles, 71 full-text studies were screened, and 27 studies were included to assess the risk of bias (ROBINS-I tool) and data extraction. After quality assessment, four studies were included, and the remaining 23 excluded studies were narratively described. Result: The included prospective studies with moderate risk of bias reported success and survival rates of onepiece implants that ranged between 95 and 98.4 % with no difference between different lengths and diameters. The acid-etched roughened surface showed higher clinical outcomes compared to other surface roughness designs. Conclusion: Promising 5-year clinical outcomes were found for one-piece zirconia implants with no difference between different diameters and lengths. Concerning surface roughness, better outcomes were found when using the acid-etched implant surface. However, due to the limited available studies, further high-quality clinical studies comparing zirconia one-piece and two-piece implants with different diameters, lengths, and surface roughness are needed. Clinical Significance: Based on this systematic review, under suitable clinical situations, the one-piece zirconia implants with diameters of 4.0 mm, 4.5 mm, or 5.5 mm and lengths of 8 mm, 10 mm, 12 mm, or 14 mm have similar promising clinical outcomes. Additionally, the acid-etched roughened implant surface may be preferable.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Clinical Outcomes of Zirconia Dental Implants: A Systematic Review
    Pieralli, S.
    Kohal, R. J.
    Jung, R. E.
    Vach, K.
    Spies, B. C.
    JOURNAL OF DENTAL RESEARCH, 2017, 96 (01) : 38 - 46
  • [2] A systematic review of the clinical survival of zirconia implants
    Hashim, Dena
    Cionca, Norbert
    Courvoisier, Delphine S.
    Mombelli, Andrea
    CLINICAL ORAL INVESTIGATIONS, 2016, 20 (07) : 1403 - 1417
  • [3] Clinical Assessment of the Relationship of Dental Implant Materials (Titanium and Zirconia) and Peri-Implantitis: A Systematic Review
    Shrivastava, Deepti
    Quadri, Syed Altafuddin
    Alshadidi, Abdulkhaliq Ali F.
    Saini, Ravinder
    Dewan, Meghna
    Fernandes, Gustavo Vicentis Oliveira
    Srivastava, Kumar Chandan
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2024,
  • [4] Clinical Performance Comparing Titanium and Titanium-Zirconium or Zirconia Dental Implants: A Systematic Review of Randomized Controlled Trials
    Fernandes, Paulo Rafael Esteves
    Otero, Ada Isis Pelaez
    Fernandes, Juliana Campos Hasse
    Nassani, Leonardo Mohamad
    Castilho, Rogerio Moraes
    de Oliveira Fernandes, Gustavo Vicentis
    DENTISTRY JOURNAL, 2022, 10 (05)
  • [5] Zirconia Implants as an Alternative to Titanium: A Systematic Review and Meta-Analysis
    Elnayef, Basel
    Lazaro, Aida
    del Amo, Fernando Suarez-Lopez
    Galindo-Moreno, Pablo
    Wang, Hom-Lay
    Gargallo-Albiol, Jordi
    Hernandez-Alfaro, Federico
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (03) : E125 - E134
  • [6] Comparison of Clinical Performance of Zirconia Implants and Titanium Implants in Animal Models: A Systematic Review
    Manzano, Guillermo
    Ruben Herrero, L.
    Montero, Javier
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (02) : 311 - 320
  • [7] A systematic review and meta-analysis on the clinical outcome of zirconia implant-restoration complex
    Adanez, Mireia Haro
    Nishihara, Hironobu
    Att, Wael
    JOURNAL OF PROSTHODONTIC RESEARCH, 2018, 62 (04) : 397 - 406
  • [8] Clinical performance of one-piece zirconia dental implants: A systematic review
    ArRejaie, Aws S.
    Al-Hamdan, Rana S.
    Basunbul, Ghadeer, I
    Abduljabbar, Tariq
    Al-Aali, Khulud A.
    Labban, Nawaf
    JOURNAL OF INVESTIGATIVE AND CLINICAL DENTISTRY, 2019, 10 (02) : e12384
  • [9] Do zirconia dental implants present better clinical results than titanium dental implants? A systematic review and meta-analysis
    da Hora Sales, Pedro Henrique
    Pessoa Barros, Ana Waleska
    de Oliveira-Neto, Olavo Barbosa
    Camello de Lima, Fernando Jose
    Tavares Carvalho, Alessandra de Albuquerque
    Leao, Jair Carneiro
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2023, 124 (01)
  • [10] Clinical outcomes of zirconia implants: a systematic review and meta-analysis
    Mohseni, Parvin
    Soufi, Ahmad
    Chrcanovic, Bruno Ramos
    CLINICAL ORAL INVESTIGATIONS, 2023, 28 (01)