Study on Performance of 6LiF/ZnS(Ag) Scintillation Screen for Scintillator Neutron Detector in China Spallation Neutron Source

被引:0
|
作者
Jiang J. [1 ,2 ]
Huang C. [3 ,5 ]
Wei Y. [1 ]
Tang B. [3 ]
Yu Q. [4 ]
Zhou S. [3 ,6 ]
Cai X. [3 ,7 ]
Deng Q. [1 ,8 ]
机构
[1] Dongguan University of Technology, Dongguan
[2] South China Normal University, Guangzhou
[3] Spallation Neutron Source Science Center-, Dongguan
[4] Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou
[5] Lanzhou University, Lanzhou
[6] Zhengzhou University, Zhengzhou
[7] Southvuest University of Science and Technology, Mianyang
[8] Shenzhen University, Shenzhen
来源
Yuanzineng Kexue Jishu/Atomic Energy Science and Technology | 2023年 / 57卷 / 08期
关键词
([!sup]6[!/sup]LiF/ZnS(Ag) scintillator; China Spallation Neutron Source; light yield; relative thermal neutron detection efficiency; scintillator neutron detector;
D O I
10.7538/yzk.2022.youxian.0860
中图分类号
学科分类号
摘要
The 6LiF/ZnS(Ag) scintillation screen is key component of the scintillation neutron detector, and its performance will directly affect the application of the detector.In order to improve the performance of scintillator neutron detector and screen out a high-performance scintillator screen that meets the requirements of neutron detector for the engineering material diffraction and the energy resolution neutron imagining diffrac-tometer on the China Spallation Neutron Source (CSNS), the No. 20 neutron beam line of Chinese Spallation Neutron Source was used to systematically study the neutron detection efficiency and the light yield of different 6LiF/ZnS(Ag) scintillation screen samples with different thicknesses and different mass ratios from Britain's Applied Scintillation Technologies (AST) manufacture. According to the results of neutron detection efficiency for these samples, the effects of 6LiF/ZnS(Ag) mass fraction ratio, thickness and substrate material type on the thermal neutron detection efficiency of 6LiF/ZnS(Ag) scintillator screen were analyzed by controlling variables. It is found that when the 6LiF: ZnS(Ag) mass fraction ratio is 1: 2, the thickness is 300 jum, the substrate material type is plastic, and the thermal neutron detection efficiency of the 6LiF/ZnS(Ag) scintillator screen is the highest. Theoretically, increasing the 6Li score or increasing the thickness of the scintillation screen can improve the thermal neutron detection efficiency of the 6LiF/ZnS(Ag) scintillator. According to the charge spectra of the emitted light of these samples, the calibrated photomultiplier tube was used to estimate the output light yield of the samples. The output light yield was compared with the number of scintillation photons generated by the scintillator. It is found that most of the photons generated by the scintillator are self-absorbed by the scintillator. For PMT, the output light yield difference between the sample and the sample is not large. On the basis of giving priority to the thermal neutron detection efficiency of the detector and taking into account the performance of the output light yield, a high-performance scintillation screen was comprehensively selected. The results show that the AST-26139 scintillation sample with 6LiF/ZnS(Ag) mass fraction ratio of 1: 2, plastic substrate and thickness of 300 ^m has the highest thermal neutron detection efficiency. The light yield from the surface of this screen is about 4. 558 X 103. The AST-26139 was chosen as the best screen for the scintillation neutron detection. In engineering application, the oblique incidence" structure for the 6LiF/ZnS(Ag) scintillation screen was designed to further improve the thermal neutron detection efficiency to meet the physical requirements of the scintillator neutron detector. © 2023 Atomic Energy Press. All rights reserved."
引用
收藏
页码:1650 / 1657
页数:7
相关论文
共 12 条
  • [1] WEI Zhiyong, ZANG Lihui, FAN Wo, Et al., Study of biological materials by neutron scatter-ing, Nuclear Techniques, 29, 9, pp. 713-720, (2006)
  • [2] CHEN Dongfeng, GOU Cheng, YE Chuntang, Neutron scattering project on CARR, Nuclear Techniques, 28, 2, pp. 127-129, (2005)
  • [3] HESS N J, SCHENTER G K, HARTMAN M R, Et al., Neutron powder diffraction and molecular simulation study of the structural evolution of Ammonia Borane from 15 to 340 K, Phys Chem A, 113, 9, pp. 572-573, (2009)
  • [4] NIIMURA N, M1NEZAKI Y, NONAKA T, Et al., Neutron Laue diffractometry with an imaging plate provides an effective data collection regime for neutron protein crystallography, Nature Structure Biology, 4, 11, pp. 909-914, (1997)
  • [5] HAN Songbai, LIU Yuntao, CHEN Dongfeng, Et al., Large-scale scientific facility at China Advanced Research Reactor for neutron scatter-ing, Chinese Science Bulletin, 60, 22, pp. 2068-2078, (2015)
  • [6] SUN Guangai, LIU Dong, GONG Jian, Et al., The neutron scattering platform of China Mian-yang Research Reactor (CMRR) and recent applications[J], Science China, 51, 9, (2021)
  • [7] WANG Fangwei, LIANG Tianjiao, YIN Wen, Et al., Conceptual design of target station and neutron scattering spectrometers for the Chinese Spallation Neutron Source, Nuclear Techniques, 28, 8, pp. 593-597, (2005)
  • [8] RHODES N J, WARDLE A G, BORAM A J, Et al., Pixelated neutron scintillation detectors using fibre optic coded arrays, Nuclear Instruments and Methods in Physics Research A, 392, pp. 315-318, (1997)
  • [9] CROW M L, HODGES J P, COOPER R G., Shifting scintillator prototype large pixel wavelength-shifting fiber detector for the POWGEN3 powder diffractometer, Nuclear Instruments and Methods in Physics Research A, 529, pp. 287-292, (2004)
  • [10] TANG Junjie, WANG Tuo, ZHANG Qiang, Et al., Characteristics of <sup>6</sup>LiF/ZnS(Ag) scintillator used in position-sensitive neutron detectors, Chinese Journal of Luminescence, 34, 1, pp. 78-81, (2013)