Research on the axial compressive behavior of double skin composite wall with steel truss

被引:2
作者
Luo, Ke-Rong [1 ,2 ]
Shu, Gan -Ping [1 ]
Liu, Zhong-Hua [1 ]
机构
[1] Southeast Univ, Natl Prestress Engn Res Ctr, Minist Educ,Sch Civil Engn, Key Lab Concrete & Prestressed Concrete Struct, Nanjing 211189, Peoples R China
[2] 2 Southeast Univ Rd, Nanjing 211189, Jiangsu, Peoples R China
关键词
Composite wall; Steel truss; Numerical analysis; Axial compressive load -carrying capacity; SHEAR-STRENGTH; CONCRETE; PERFORMANCE; COLUMNS; PANELS;
D O I
10.1016/j.istruc.2024.106159
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a research on the axial compressive behavior of double skin composite wall(DSCW) with steel truss, which is a novel type of composite wall. The steel truss is constructed by two angles and kinked rebar is acting as the interface connector. Experimental study was introduced briefly and software ABAQUS was adopted for numerical simulation analysis. By comparing with the experimental results, the accuracy of the finite element model was verified and then structural behavior of the walls was comprehensively evaluated. A parametric study was carried out to investigate the influences of the strength of steel plate and infilled concrete, truss horizontal spacing to thickness ratio on the compression responses of the composite wall. The results show that the better ductility of the composite wall can be achieved by the lower concrete strength and higher steel plate strength. Besides, the strength of the concrete and the steel plate tends to have a linear correlation with the load-carrying capacity. The horizontal spacing to thickness ratio has the significant influence on the failure mode of the composite wall and local buckling of steel plate can be avoided when the ratio is less than a certain value. In addition, the calculation formula for the axial compressive load-carrying capacity of the composite wall was proposed to provide a reference basis for the application of this type of composite walls in practice.
引用
收藏
页数:11
相关论文
共 43 条
[1]  
[Anonymous], 2020, ABAQUS analysis user's manual (version 2020)
[2]  
[Anonymous], 2011, 22812010 GBT
[3]  
CECS, 2018, Technical Standard for Structures with Concrete-Filled Multicellular Steel Tube Walls
[4]  
Chen Ji, 2014, Stability of Steel Structures: Theory and Design
[5]   Axial compression stability of thin double-steel-plate and concrete composite shear wall [J].
Chen, Zhihua ;
Zi, Zhenyu ;
Zhou, Ting ;
Wu, Yapeng .
STRUCTURES, 2021, 34 :3866-3881
[6]   Strength and behavior of steel plate-concrete wall structures using ordinary and eco-oriented cement concrete under axial compression [J].
Choi, Byong-Jeong ;
Kang, Cheol-Kyu ;
Park, Ho-Young .
THIN-WALLED STRUCTURES, 2014, 84 :313-324
[7]   Compressive performance with variation of yield strength and width-thickness ratio for steel plate-concrete wall structures [J].
Choi, Byong-Jeong ;
Kim, Won-Ki ;
Kim, Woo-Bum ;
Kang, Cheol-Kyu .
STEEL AND COMPOSITE STRUCTURES, 2013, 14 (05) :473-491
[8]   Shear strength of steel-concrete-steel composite panels. Part II - detailed numerical modelling of performance [J].
Clubley, SK ;
Moy, SSJ ;
Xiao, RY .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2003, 59 (06) :795-808
[9]   Shear strength of steel-concrete-steel composite panels. Part I - testing and numerical modelling [J].
Clubley, SK ;
Moy, SSJ ;
Xiao, RY .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2003, 59 (06) :781-794
[10]  
Clubley SK, 1999, ADVANCES IN STEEL STRUCTURES, VOLS 1 AND 2, P467