Validation of Proprietary and Novel Step-counting Algorithms for Individuals Ambulating With a Lower Limb Prosthesis

被引:0
作者
Rigot, Stephanie K. [1 ,2 ,3 ]
Maronati, Rachel [1 ,2 ]
Lettenberger, Ahalya [1 ,2 ,4 ]
O'Brien, Megan K. [1 ,2 ,3 ]
Alamdari, Kayla [1 ,2 ]
Hoppe-Ludwig, Shenan [1 ,2 ]
Mcguire, Matthew [1 ,2 ]
Looft, John M. [5 ,6 ,7 ]
Wacek, Amber [5 ,6 ]
Cave Ii, Juan [5 ,6 ]
Sauerbrey, Matthew [5 ,6 ]
Jayaraman, Arun [1 ,2 ,3 ,8 ,9 ]
机构
[1] Shirley Ryan Ability Lab, Max Nader Ctr Rehabil Technol & Outcomes Res, Chicago, IL USA
[2] Shirley Ryan Ability Lab, Ctr Bion Med, Chicago, IL USA
[3] Northwestern Univ, Dept Phys Med & Rehabil, Chicago, IL USA
[4] Rice Univ, Dept Bioengn, Houston, TX USA
[5] Minneapolis Vet Affairs Hlth Care Syst, Dept Prosthet, Mot Anal Lab, Minneapolis, MN USA
[6] Minneapolis Vet Affairs Hlth Care Syst, Minneapolis Adapt Design & Engn MADE, Dept Res, Minneapolis, MN USA
[7] Univ Minnesota, Med Sch, Div Rehabil Sci, Minneapolis, MN USA
[8] Northwestern Univ, Dept Phys Therapy & Human Movement Sci, Chicago, IL USA
[9] Shirley Ryan Abil Lab, 355 E Erie St, Chicago, IL 60611 USA
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 2024年 / 105卷 / 03期
关键词
Accelerometry; Actigraphy; Lower limb amputation; Physical activity; Prosthesis; Rehabilitation; Walking; DAILY PHYSICAL-ACTIVITY; HEART-RATE RESPONSE; ENERGY-COST; WALKING; AMPUTATION; ACCURACY; PEOPLE; RELIABILITY;
D O I
10.1016/j.apmr.2023.10.008
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To compare the accuracy and reliability of 10 different accelerometer-based step-counting algorithms for individuals with lower limb loss, accounting for different clinical characteristics and real-world activities. Design: Cross-sectional study. Setting: General community setting (ie, institutional research laboratory and community free -living). Participants: Forty-eight individuals with a lower limb amputation (N=48) wore an ActiGraph (AG) wGT3x-BT accelerometer proximal to the foot of their prosthetic limb during labeled indoor/outdoor activities and community free -living. Interventions: Not applicable. Main Outcome Measures: Intraclass correlation coefficient (ICC), absolute and root mean square error (RMSE), and Bland Altman plots were used to compare true (manual) step counts to estimated step counts from the proprietary AG Default algorithm and low frequency extension filter, as well as from 8 novel algorithms based on continuous wavelet transforms, fast Fourier transforms (FFTs), and peak detection. Results: All algorithms had excellent agreement with manual step counts (ICC>0.9). The AG Default and FFT algorithms had the highest overall error (RMSE=17.81 and 19.91 steps, respectively), widest limits of agreement, and highest error during outdoor and ramp ambulation. The AG Default algorithm also had among the highest error during indoor ambulation and stairs, while a FFT algorithm had the highest error during stationary tasks. Peak detection algorithms, especially those using pre-set parameters with a trial-specific component, had among the lowest error across all activities (RMSE=4.07-8.99 steps). Conclusions: Because of its simplicity and accuracy across activities and clinical characteristics, we recommend the peak detection algorithm with set parameters to count steps using a prosthetic-worn AG among individuals with lower limb loss for clinical and research applications. Archives of Physical Medicine and Rehabilitation 2024;105:546-57 (c) 2023 by the American Congress of Rehabilitation Medicine. Published by Elsevier Inc. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)
引用
收藏
页码:546 / 557
页数:12
相关论文
共 40 条
[1]   How Well iPhones Measure Steps in Free-Living Conditions: Cross-Sectional Validation Study [J].
Amagasa, Shiho ;
Kamada, Masamitsu ;
Sasai, Hiroyuki ;
Fukushima, Noritoshi ;
Kikuchi, Hiroyuki ;
Lee, I-Min ;
Inoue, Shigeru .
JMIR MHEALTH AND UHEALTH, 2019, 7 (01)
[2]  
[Anonymous], 2009, JPO J Prosthet Orthot
[3]  
[Anonymous], 2012, Actigraph White Paper: Low Frequency Extension Filter
[4]  
[Anonymous], 2021, Local coverage determination: positive airway pressure (PAP) devices for the treatment of obstructive sleep apnea (L33718)
[5]  
Arch ElisaS., 2017, JPO: Journal of Prosthetics and Orthotics, V29, P73
[6]   Step Counting: A Review of Measurement Considerations and Health-Related Applications [J].
Bassett, David R., Jr. ;
Toth, Lindsay P. ;
LaMunion, Samuel R. ;
Crouter, Scott E. .
SPORTS MEDICINE, 2017, 47 (07) :1303-1315
[7]   Performance-based outcome measures are associated with cadence variability during community ambulation among individuals with a transtibial amputation [J].
Beisheim, Emma Haldane ;
Arch, Elisa Sarah ;
Horne, John Robert ;
Sions, Jaclyn Megan .
PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2020, 44 (04) :215-224
[8]   Daily physical activity and heart rate response in people with a unilateral transtibial amputation for vascular disease [J].
Bussmann, JB ;
Grootscholten, EA ;
Stam, HJ .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2004, 85 (02) :240-244
[9]   Daily physical activity and heart rate response in people with a unilateral traumatic transtibial amputation [J].
Bussmann, Johannes B. ;
Schraulven, Hannelore J. ;
Stam, Henk J. .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2008, 89 (03) :430-434
[10]   Pedometer accuracy in nursing home and community-dwelling older adults [J].
Cyarto, EV ;
Myers, AM ;
Tudor-Locke, C .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (02) :205-209