Effects of Source Depletion on Vapor Intrusion Risk Assessment

被引:0
作者
Zhong M.-S. [1 ,2 ,3 ]
Wang Y. [1 ,2 ,3 ]
Jiang L. [1 ,2 ,3 ]
Zhang L.-N. [1 ,2 ,3 ]
Ma L. [1 ,2 ,3 ]
Zhang R.-H. [1 ,2 ,3 ]
Zhao Y. [1 ,2 ,3 ]
Li J.-H. [1 ,2 ,3 ]
机构
[1] Beijing Municipal Research Institute of Eco-Environniental Protection, Beijing
[2] National Engineering Research Centre for Urban Environmental Pollution Control, Beijing
[3] Beijing Key Laboratory for Risk Modeling and Remediation of Contaminated Sites, Beijing
来源
Huanjing Kexue/Environmental Science | 2023年 / 44卷 / 08期
关键词
risk assessment; SD model; source depletion; vapor intrusion; volatile organic compounds(VOCs);
D O I
10.13227/j.hjkx.202208262
中图分类号
学科分类号
摘要
The current regulatory site investigation employs the J&E model to predict vapor intrusion risk. However, the J&E model assumes that the source concentration is constant for a given exposure period, which is not consistent with the actual site source under depletion. In this study, we compared the differences between the J&E model (constant source), SD^source depletion model, and RBCA source depletion model for predicting indoor concentration variation as well as the risk levels during the exposure period with a case study in Beijing. The results showed that the source and indoor air concentrations predicted by the SD and RBCA models showed exponential decreases, whereas those predicted by the J&E model maintained high concentrations throughout the exposure period, which greatly overestimated the risk. The RBCA predicted source depletion at the fastest rate, but the predicted indoor air concentrations were still lower than those of the SD model, which was related to the fact that the RBCA did not consider the effect of buildings on source depletion and did not follow mass conservation. Further, the sensitivity analysis showed that the pressure difference ((IP) had the greatest influence on the source concentration in the SD model. For the calculated carcinogenic risk and hazard quotients, the J&E constant source model, the SD source depletion model, and the RBCA source depletion model were ranked in descending order. The results indicated that in general the J&E model was too conservative, the RBCA model may have underestimated risk, and the SD model was more suitable for quantifying vapor intrusion risk in reality. © 2023 Science Press. All rights reserved.
引用
收藏
页码:4271 / 4278
页数:7
相关论文
共 48 条
  • [1] Vapor intrusion pathway
  • [2] a practical guideline [R], (2007)
  • [3] OSWER 9200.2-154, Technical guide for assessing and mitigating the vapor intrusion pathway from subsurface vapor sources to indoor air
  • [4] Technical guide for addressing petroleum vapor intrusion at leaking underground storage lank sites [S]
  • [5] Wu X F, Xie L, Zhao H Y., Comparative study on the health risk of different exposure pathways at soil and groundwater contaminated sites[J], China Environmental Science, 32, 2, pp. 345-350, (2012)
  • [6] Fan C, Wang C S, Chen Y C, Et al., Risk assessment of exposure to volatile organic compounds in groundwater in Taiwan [J], Science of the Total Environment, 407, 7, pp. 2165-2174, (2009)
  • [7] Zhu H, Ye S J, Wu J C, Et al., Characteristics of soil lilhology and pollutants in typical contamination sites in China, Earth Science Frontiers, 28, 5, pp. 26-34, (2021)
  • [8] Gao C R, Wang J T., Research on groundwater organic contamination characteristics in 69 cities of China [J], Acta for predicting buildings J Geoscientica Sinica, 32, 5, pp. 581-591, (2011)
  • [9] Superfund remedy report-16th edition[R], pp. 1-4, (2020)
  • [10] Cernansky R., It came from beneath